Summary
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could
cause disclosure of sensitive information, denial of service, or modification of data if an attacker
is able to intercept network traffic.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-21 15:05 UTC
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
Impacted products
6 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Schneider Electric | PowerLogic ION9000 |
Affected:
Prior to 4.0.0
|
guessed | |
| Schneider Electric | PowerLogic ION7400 |
Affected:
Prior to 4.0.0
|
guessed | |
| Schneider Electric | PowerLogic PM8000 |
Affected:
Prior to 4.0.0
|
guessed | |
| Schneider Electric | PowerLogic ION8650 |
Affected:
All Versions
|
guessed | |
| Schneider Electric | PowerLogic ION8800 |
Affected:
All Versions
|
guessed | |
| Schneider Electric | Legacy ION products |
Affected:
All Versions
|
guessed |
Date Public
2023-05-09 13:18
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:39:38.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-21T15:05:13.390998Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-21T15:05:49.099Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION9000",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION7400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": " PowerLogic PM8000",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION8650",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION8800",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy ION products",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2023-05-09T13:18:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-22T13:25:40.615Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-46680",
"datePublished": "2023-05-22T13:25:40.615Z",
"dateReserved": "2022-12-06T21:51:38.755Z",
"dateUpdated": "2025-01-21T15:05:49.099Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-46680",
"date": "2026-09-05",
"epss": "0.00379",
"percentile": "0.30896"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.0.0\", \"matchCriteriaId\": \"50C920E5-0F21-4DBB-9D0E-424F8C1A9B85\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.0.0\", \"matchCriteriaId\": \"E43DFCA4-7ED0-4E61-872A-ECD08659A52B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.0.0\", \"matchCriteriaId\": \"4A560510-3A07-4EBB-8E2D-E473EE9B59C9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7EFB1251-11AE-4A77-AB68-26D6B58C8F33\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"46E8E79E-6DA7-4094-9622-3B91D5913493\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\"}]",
"id": "CVE-2022-46680",
"lastModified": "2024-11-21T07:30:53.443",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2023-05-22T14:15:09.433",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-319\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-46680\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-05-22T14:15:09.433\",\"lastModified\":\"2026-06-17T05:12:11.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\"}],\"affected\":[{\"source\":\"cybersecurity@se.com\",\"affectedData\":[{\"vendor\":\"Schneider Electric\",\"product\":\"PowerLogic ION9000\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Prior to 4.0.0\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"PowerLogic ION7400\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Prior to 4.0.0\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\" PowerLogic PM8000\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Prior to 4.0.0\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"PowerLogic ION8650\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"All Versions\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"PowerLogic ION8800\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"All Versions\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"Legacy ION products\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"All Versions\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-01-21T15:05:13.390998Z\",\"id\":\"CVE-2022-46680\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"yes\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"50C920E5-0F21-4DBB-9D0E-424F8C1A9B85\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"E43DFCA4-7ED0-4E61-872A-ECD08659A52B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"4A560510-3A07-4EBB-8E2D-E473EE9B59C9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EFB1251-11AE-4A77-AB68-26D6B58C8F33\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46E8E79E-6DA7-4094-9622-3B91D5913493\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"redhat_vex": {
"current_release_date": "2025-05-29T01:50:05+00:00",
"cve": "CVE-2022-46680",
"id": "CVE-2022-46680",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-46680",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-46680.json",
"version": "3"
},
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:39:38.551Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-46680\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-21T15:05:13.390998Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-21T15:05:31.148Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to 4.0.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION7400\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to 4.0.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \" PowerLogic PM8000\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to 4.0.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION8650\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION8800\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Legacy ION products\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-05-09T13:18:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-319\", \"description\": \"CWE-319 Cleartext Transmission of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-05-22T13:25:40.615Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-46680\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-21T15:05:49.099Z\", \"dateReserved\": \"2022-12-06T21:51:38.755Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-05-22T13:25:40.615Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…