CVE-2023-31175 (GCVE-0-2023-31175)
Vulnerability from cvelistv5 – Published: 2023-08-31 15:31 – Updated: 2024-10-01 17:03
VLAI?
Summary
An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.
See Instruction Manual Appendix A and Appendix E dated 20230615 for more details.
This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
Severity ?
8.8 (High)
CWE
- CWE-250 - Execution with Unnecesary Privileges
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schweitzer Engineering Laboratories | SEL-5037 SEL Grid Configurator |
Affected:
0 , < 4.5.0.20
(custom)
|
Credits
Andrea Palanca of Nozomi Networks
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:45:25.726Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://selinc.com/support/security-notifications/external-reports/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.nozominetworks.com/blog/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-31175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-01T17:03:22.630108Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T17:03:31.524Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "SEL-5037 SEL Grid Configurator",
"vendor": "Schweitzer Engineering Laboratories",
"versions": [
{
"lessThan": "4.5.0.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Andrea Palanca of Nozomi Networks"
}
],
"datePublic": "2023-08-31T16:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
}
],
"value": "\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-122",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-122 Privilege Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250 Execution with Unnecesary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-31T15:31:33.536Z",
"orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
"shortName": "SEL"
},
"references": [
{
"url": "https://selinc.com/support/security-notifications/external-reports/"
},
{
"url": "https://www.nozominetworks.com/blog/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Execution with Unnecessary Privileges",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
"assignerShortName": "SEL",
"cveId": "CVE-2023-31175",
"datePublished": "2023-08-31T15:31:33.536Z",
"dateReserved": "2023-04-24T23:20:01.609Z",
"dateUpdated": "2024-10-01T17:03:31.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.5.0.20\", \"matchCriteriaId\": \"8DE1284E-619F-49AC-AE96-0A4ECD76292B\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\\n\\n\\n\\n\\n\\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\\n\\n\\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\\n\\n\"}]",
"id": "CVE-2023-31175",
"lastModified": "2024-11-21T08:01:33.777",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"security@selinc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.0, \"impactScore\": 6.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2023-08-31T16:15:09.923",
"references": "[{\"url\": \"https://selinc.com/support/security-notifications/external-reports/\", \"source\": \"security@selinc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.nozominetworks.com/blog/\", \"source\": \"security@selinc.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://selinc.com/support/security-notifications/external-reports/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.nozominetworks.com/blog/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "security@selinc.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"security@selinc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-250\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-31175\",\"sourceIdentifier\":\"security@selinc.com\",\"published\":\"2023-08-31T16:15:09.923\",\"lastModified\":\"2024-11-21T08:01:33.777\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\\n\\n\\n\\n\\n\\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\\n\\n\\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@selinc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security@selinc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-250\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.20\",\"matchCriteriaId\":\"8DE1284E-619F-49AC-AE96-0A4ECD76292B\"}]}]}],\"references\":[{\"url\":\"https://selinc.com/support/security-notifications/external-reports/\",\"source\":\"security@selinc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.nozominetworks.com/blog/\",\"source\":\"security@selinc.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://selinc.com/support/security-notifications/external-reports/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.nozominetworks.com/blog/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://selinc.com/support/security-notifications/external-reports/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.nozominetworks.com/blog/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T14:45:25.726Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-31175\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-01T17:03:22.630108Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-01T17:03:27.360Z\"}}], \"cna\": {\"title\": \"Execution with Unnecessary Privileges\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Andrea Palanca of Nozomi Networks\"}], \"impacts\": [{\"capecId\": \"CAPEC-122\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-122 Privilege Abuse\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schweitzer Engineering Laboratories\", \"product\": \"SEL-5037 SEL Grid Configurator\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.5.0.20\", \"versionType\": \"custom\"}], \"platforms\": [\"Windows\"], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-08-31T16:00:00.000Z\", \"references\": [{\"url\": \"https://selinc.com/support/security-notifications/external-reports/\"}, {\"url\": \"https://www.nozominetworks.com/blog/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\\n\\n\\n\\n\\n\\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\\n\\n\\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\\n\\n\u003cbr\u003e\u003cbr\u003e\\n\\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\\n\\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-250\", \"description\": \"CWE-250 Execution with Unnecesary Privileges\"}]}], \"providerMetadata\": {\"orgId\": \"5804bb70-792c-43e0-8596-486cc0efe699\", \"shortName\": \"SEL\", \"dateUpdated\": \"2023-08-31T15:31:33.536Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-31175\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-01T17:03:31.524Z\", \"dateReserved\": \"2023-04-24T23:20:01.609Z\", \"assignerOrgId\": \"5804bb70-792c-43e0-8596-486cc0efe699\", \"datePublished\": \"2023-08-31T15:31:33.536Z\", \"assignerShortName\": \"SEL\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…