CVE-2023-46290
Vulnerability from cvelistv5
Published
2023-10-27 18:10
Modified
2024-08-02 20:45
Severity ?
EPSS score ?
Summary
Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability
References
▼ | URL | Tags | |
---|---|---|---|
PSIRT@rockwellautomation.com | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165 | Permissions Required, Vendor Advisory |
Impacted products
▼ | Vendor | Product |
---|---|---|
Rockwell Automation | FactoryTalk® Services Platform |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.833Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk\u00ae Services Platform", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "versions before 2.80" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": " This vulnerability was found internally during routine testing." } ], "datePublic": "2023-10-26T13:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\u003c/span\u003e\n\n" } ], "value": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\n\n" } ], "impacts": [ { "capecId": "CAPEC-633", "descriptions": [ { "lang": "en", "value": "CAPEC-633 Token Impersonation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-27T18:10:50.923Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cul\u003e\u003cli\u003eInstall the respective \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx?crumb=113\u0026amp;versions=61602,60883,59837,59480,58564,57413,58591,59481,59482,59483,59484,59485,59486,59487,59488,59490,59491,59492,59493,59494,59495,59496\"\u003eFactoryTalk Services Version\u003c/a\u003e\u0026nbsp;that remediates the issue.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "\n * Install the respective FactoryTalk Services Version https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx \u00a0that remediates the issue.\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2023-46290", "datePublished": "2023-10-27T18:10:50.923Z", "dateReserved": "2023-10-20T18:01:46.095Z", "dateUpdated": "2024-08-02T20:45:40.833Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-46290\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2023-10-27T19:15:41.560\",\"lastModified\":\"2023-11-07T19:09:56.033\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Debido a una l\u00f3gica de c\u00f3digo inadecuada, un actor de amenazas no autenticado previamente podr\u00eda obtener un token de usuario del sistema operativo Windows local a trav\u00e9s del servicio web FactoryTalk\u00ae Services Platform y luego usar el token para iniciar sesi\u00f3n en FactoryTalk\u00ae Services Platform. Esta vulnerabilidad solo se puede aprovechar si el usuario autorizado no inici\u00f3 sesi\u00f3n previamente en el servicio web FactoryTalk\u00ae Services Platform.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.80\",\"matchCriteriaId\":\"86F8AE4A-2067-4989-BED5-B4CB8A03E8BB\"}]}]}],\"references\":[{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Permissions Required\",\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.