CVE-2023-5253 (GCVE-0-2023-5253)
Vulnerability from cvelistv5 – Published: 2024-01-15 10:53 – Updated: 2025-06-17 21:09- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Nozomi Networks | Guardian |
Affected:
0 , < 23.3.0
(semver)
|
guessed | |
| Nozomi Networks | CMC |
Affected:
0 , < 23.3.0
(semver)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:52:08.520Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://security.nozominetworks.com/NN-2023:12-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5253",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-16T16:05:53.153585Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:09:23.231Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Guardian",
"vendor": "Nozomi Networks",
"versions": [
{
"lessThan": "23.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CMC",
"vendor": "Nozomi Networks",
"versions": [
{
"lessThan": "23.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "This issue was found by Nozomi Networks Product Security team during an internal VAPT testing session."
}
],
"datePublic": "2024-01-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eA missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\n\n\n\nMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-20T11:38:34.932Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://security.nozominetworks.com/NN-2023:12-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v23.3.0 or later.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Upgrade to v23.3.0 or later."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eUse internal firewall features to limit access to the web management interface.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Use internal firewall features to limit access to the web management interface."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2023-5253",
"datePublished": "2024-01-15T10:53:56.305Z",
"dateReserved": "2023-09-28T12:41:27.922Z",
"dateUpdated": "2025-06-17T21:09:23.231Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-5253",
"date": "2026-10-31",
"epss": "0.00451",
"percentile": "0.39207"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nozominetworks:cmc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27F4311F-0751-4645-9BC7-05946A253330",
"versionEndExcluding": "23.3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D44D965F-3128-4F2C-A582-E84247A16CF5",
"versionEndExcluding": "23.3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\n\n\n\nMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information."
},
{
"lang": "es",
"value": "Una verificaci\u00f3n de autenticaci\u00f3n faltante en el canal WebSocket utilizado para la integraci\u00f3n de Check Point IoT en Nozomi Networks Guardian y CMC puede permitir que un atacante no autenticado obtenga datos de activos sin autenticaci\u00f3n. Los usuarios maliciosos no autenticados con conocimiento sobre el sistema subyacente pueden extraer informaci\u00f3n de activos."
}
],
"id": "CVE-2023-5253",
"lastModified": "2024-11-21T08:41:22.837",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"automatable": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityRequirements": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"subsequentSystemAvailability": "NONE",
"subsequentSystemConfidentiality": "LOW",
"subsequentSystemIntegrity": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"vulnerableSystemAvailability": "NONE",
"vulnerableSystemConfidentiality": "LOW",
"vulnerableSystemIntegrity": "NONE"
},
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
}
]
},
"published": "2024-01-15T11:15:08.627",
"references": [
{
"source": "prodsec@nozominetworks.com",
"tags": [
"Third Party Advisory"
],
"url": "https://security.nozominetworks.com/NN-2023:12-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://security.nozominetworks.com/NN-2023:12-01"
}
],
"sourceIdentifier": "prodsec@nozominetworks.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Guardian",
"vendor": "Nozomi Networks",
"versions": [
{
"lessThan": "23.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CMC",
"vendor": "Nozomi Networks",
"versions": [
{
"lessThan": "23.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "prodsec@nozominetworks.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nozominetworks:cmc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27F4311F-0751-4645-9BC7-05946A253330",
"versionEndExcluding": "23.3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D44D965F-3128-4F2C-A582-E84247A16CF5",
"versionEndExcluding": "23.3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\n\n\n\nMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information."
},
{
"lang": "es",
"value": "Una verificaci\u00f3n de autenticaci\u00f3n faltante en el canal WebSocket utilizado para la integraci\u00f3n de Check Point IoT en Nozomi Networks Guardian y CMC puede permitir que un atacante no autenticado obtenga datos de activos sin autenticaci\u00f3n. Los usuarios maliciosos no autenticados con conocimiento sobre el sistema subyacente pueden extraer informaci\u00f3n de activos."
}
],
"id": "CVE-2023-5253",
"lastModified": "2026-06-17T06:48:11.073",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-5253",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-16T16:05:53.153585Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-01-15T11:15:08.627",
"references": [
{
"source": "prodsec@nozominetworks.com",
"tags": [
"Third Party Advisory"
],
"url": "https://security.nozominetworks.com/NN-2023:12-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://security.nozominetworks.com/NN-2023:12-01"
}
],
"sourceIdentifier": "prodsec@nozominetworks.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T23:37:31+00:00",
"cve": "CVE-2023-5253",
"id": "CVE-2023-5253",
"initial_release_date": "2023-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-5253.json",
"version": "3"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.