CVE-2023-5985 (GCVE-0-2023-5985)
Vulnerability from cvelistv5 – Published: 2023-11-15 03:35 – Updated: 2024-08-29 15:18
VLAI?
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability
exists that could cause compromise of a user’s browser when an attacker with admin privileges
has modified system values.
Severity ?
4.8 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | ION8650 |
Affected:
All versions
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.120Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5985",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T15:18:22.109304Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T15:18:46.931Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ION8650",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ION8800 ",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"datePublic": "2023-11-15T03:25:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\nexists that could cause compromise of a user\u2019s browser when an attacker with admin privileges\nhas modified system values.\n\n\n\n"
}
],
"value": "\n\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\nexists that could cause compromise of a user\u2019s browser when an attacker with admin privileges\nhas modified system values.\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-15T03:35:17.617Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5985",
"datePublished": "2023-11-15T03:35:17.617Z",
"dateReserved": "2023-11-07T10:56:13.627Z",
"dateUpdated": "2024-08-29T15:18:46.931Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:ion8650_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F157E99-370C-46CD-BB4F-88BC5B55E8B0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:ion8650:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1DA97CA0-DDE0-4418-9D72-7D463C003693\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:ion8800_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1936E11C-833A-4E02-A0F9-D53E12FB88D5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:ion8800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B3449157-3715-4D89-A3BD-49EE47160B25\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\n\\n\\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\\nexists that could cause compromise of a user\\u2019s browser when an attacker with admin privileges\\nhas modified system values.\\n\\n\\n\\n\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad CWE-79: Neutralizaci\\u00f3n Inadecuada de la Entrada Durante la Generaci\\u00f3n de P\\u00e1ginas Web que podr\\u00eda comprometer el navegador de un usuario cuando un atacante con privilegios de administrador ha modificado los valores del sistema.\"}]",
"id": "CVE-2023-5985",
"lastModified": "2024-11-21T08:42:55.427",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}]}",
"published": "2023-11-15T04:15:19.290",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-5985\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-11-15T04:15:19.290\",\"lastModified\":\"2024-11-21T08:42:55.427\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\\nexists that could cause compromise of a user\u2019s browser when an attacker with admin privileges\\nhas modified system values.\\n\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-79: Neutralizaci\u00f3n Inadecuada de la Entrada Durante la Generaci\u00f3n de P\u00e1ginas Web que podr\u00eda comprometer el navegador de un usuario cuando un atacante con privilegios de administrador ha modificado los valores del sistema.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ion8650_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F157E99-370C-46CD-BB4F-88BC5B55E8B0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ion8650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DA97CA0-DDE0-4418-9D72-7D463C003693\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ion8800_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1936E11C-833A-4E02-A0F9-D53E12FB88D5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ion8800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B3449157-3715-4D89-A3BD-49EE47160B25\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T08:14:25.120Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-5985\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-29T15:18:22.109304Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-29T15:18:29.825Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 4.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"ION8650\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ION8800 \", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-11-15T03:25:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\n\\n\\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\\nexists that could cause compromise of a user\\u2019s browser when an attacker with admin privileges\\nhas modified system values.\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\\n\\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\\nexists that could cause compromise of a user\\u2019s browser when an attacker with admin privileges\\nhas modified system values.\\n\\n\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-11-15T03:35:17.617Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-5985\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-29T15:18:46.931Z\", \"dateReserved\": \"2023-11-07T10:56:13.627Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-11-15T03:35:17.617Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…