CVE-2025-2875 (GCVE-0-2025-2875)
Vulnerability from cvelistv5 – Published: 2025-05-14 08:46 – Updated: 2025-05-14 13:38- CWE-610 - Externally Controlled Reference to a Resource in Another Sphere
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon Controllers M241 / M251 |
Affected:
Versions prior to v5.3.12.48
|
|
| Schneider Electric | Modicon Controllers M258 / LMC058 |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2875",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-14T13:38:22.136795Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-14T13:38:32.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241 / M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v5.3.12.48"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M258 / LMC058",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to\naccess resources.\n\n\u003cbr\u003e"
}
],
"value": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to\naccess resources."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-610",
"description": "CWE-610 Externally Controlled Reference to a Resource in Another Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-14T08:46:19.416Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-2875",
"datePublished": "2025-05-14T08:46:19.416Z",
"dateReserved": "2025-03-27T15:03:20.150Z",
"dateUpdated": "2025-05-14T13:38:32.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-2875",
"date": "2026-05-28",
"epss": "0.00522",
"percentile": "0.67151"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-2875\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-05-14T09:15:20.097\",\"lastModified\":\"2025-05-16T14:43:56.797\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to\\naccess resources.\"},{\"lang\":\"es\",\"value\":\"CWE-610: Existe una vulnerabilidad de referencia controlada externamente a un recurso en otra esfera que podr\u00eda causar una p\u00e9rdida de confidencialidad cuando un atacante no autenticado manipula la URL del servidor web del controlador para acceder a los recursos.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-610\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-2875\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-14T13:38:22.136795Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-14T13:38:27.992Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Modicon Controllers M241 / M251\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions prior to v5.3.12.48\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Modicon Controllers M258 / LMC058\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\\u2019s webserver URL to\\naccess resources.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\\u2019s webserver URL to\\naccess resources.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-610\", \"description\": \"CWE-610 Externally Controlled Reference to a Resource in Another Sphere\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-05-14T08:46:19.416Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-2875\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-14T13:38:32.786Z\", \"dateReserved\": \"2025-03-27T15:03:20.150Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-05-14T08:46:19.416Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2025-AVI-0398
Vulnerability from certfr_avis - Published: - Updated:
Une vulnérabilité a été découverte dans les produits Schneider Electric. Elle permet à un attaquant de provoquer une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | Modicon Controllers | Modicon Controllers M258 toutes versions pour la vulnérabilité CVE-2025-2875 | ||
| Schneider Electric | Modicon Controllers | Modicon Controllers LMC058 toutes versions pour la vulnérabilité CVE-2025-2875 | ||
| Schneider Electric | Modicon Controllers | Modicon Controllers M241 versions antérieures à 5.3.12.48 | ||
| Schneider Electric | Modicon Controllers | Modicon Controllers M251 versions antérieures à 5.3.12.48 |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon Controllers M258 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2875",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controllers LMC058 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2875",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controllers M241 versions ant\u00e9rieures \u00e0 5.3.12.48",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controllers M251 versions ant\u00e9rieures \u00e0 5.3.12.48",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-2875",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2875"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0398",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-05-13T00:00:00.000000"
}
],
"risks": [
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "Une vuln\u00e9rabilit\u00e9 a \u00e9t\u00e9 d\u00e9couverte dans les produits Schneider Electric. Elle permet \u00e0 un attaquant de provoquer une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Vuln\u00e9rabilit\u00e9 dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-05-13",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-133-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
}
]
}
CERTFR-2025-AVI-0398
Vulnerability from certfr_avis - Published: - Updated:
Une vulnérabilité a été découverte dans les produits Schneider Electric. Elle permet à un attaquant de provoquer une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | Modicon Controllers | Modicon Controllers M258 toutes versions pour la vulnérabilité CVE-2025-2875 | ||
| Schneider Electric | Modicon Controllers | Modicon Controllers LMC058 toutes versions pour la vulnérabilité CVE-2025-2875 | ||
| Schneider Electric | Modicon Controllers | Modicon Controllers M241 versions antérieures à 5.3.12.48 | ||
| Schneider Electric | Modicon Controllers | Modicon Controllers M251 versions antérieures à 5.3.12.48 |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon Controllers M258 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2875",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controllers LMC058 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2875",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controllers M241 versions ant\u00e9rieures \u00e0 5.3.12.48",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controllers M251 versions ant\u00e9rieures \u00e0 5.3.12.48",
"product": {
"name": "Modicon Controllers",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-2875",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2875"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0398",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-05-13T00:00:00.000000"
}
],
"risks": [
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "Une vuln\u00e9rabilit\u00e9 a \u00e9t\u00e9 d\u00e9couverte dans les produits Schneider Electric. Elle permet \u00e0 un attaquant de provoquer une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Vuln\u00e9rabilit\u00e9 dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-05-13",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-133-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
}
]
}
BDU:2025-07451
Vulnerability from fstec - Published: 13.05.2025{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"CVSS 4.0": "AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (Modicon M258), - (Modicon LMC058), \u0434\u043e 5.3.12.48 (Modicon M241), \u0434\u043e 5.3.12.48 (Modicon M251)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u043e\u0440\u0442\u0430\u043c 80/HTTP \u0438 443/HTTPS;\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0443 \u0438\u0437 \u0434\u0440\u0443\u0433\u0438\u0445 \u043f\u043e\u0434\u0441\u0435\u0442\u0435\u0439;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u0438\u0437 \u0432\u043d\u0435\u0448\u043d\u0438\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN).\n\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "13.05.2025",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "25.06.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "25.06.2025",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2025-07451",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2025-2875",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Modicon M258, Modicon LMC058, Modicon M241, Modicon M251",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f Modicon Controllers, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u043d\u044b\u043c \u0432\u043d\u0435\u0448\u043d\u0438\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u0438\u043c\u0435\u043d\u0435\u043c \u0438\u043b\u0438 \u043f\u0443\u0442\u0435\u043c \u0444\u0430\u0439\u043b\u0430 \u043f\u0440\u0438 \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u0434\u0430\u043d\u043d\u044b\u0445, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043e\u043a\u0430\u0437\u0430\u0442\u044c \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u043a\u043e\u043d\u0444\u0438\u0434\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u043c\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0412\u043d\u0435\u0448\u043d\u0435 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u0430\u044f \u0441\u0441\u044b\u043b\u043a\u0430 \u043d\u0430 \u0440\u0435\u0441\u0443\u0440\u0441 \u0434\u0440\u0443\u0433\u043e\u0439 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 (CWE-610)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f Modicon Controllers \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u043d\u044b\u043c \u0432\u043d\u0435\u0448\u043d\u0438\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u0438\u043c\u0435\u043d\u0435\u043c \u0438\u043b\u0438 \u043f\u0443\u0442\u0435\u043c \u0444\u0430\u0439\u043b\u0430 \u043f\u0440\u0438 \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u0434\u0430\u043d\u043d\u044b\u0445. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u043e\u043a\u0430\u0437\u0430\u0442\u044c \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u043a\u043e\u043d\u0444\u0438\u0434\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u043c\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://nvd.nist.gov/vuln/detail/CVE-2025-2875\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-610",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.1 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u043e\u0446\u0435\u043d\u043a\u0430 CVSS 4.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 8,7)"
}
FKIE_CVE-2025-2875
Vulnerability from fkie_nvd - Published: 2025-05-14 09:15 - Updated: 2026-04-15 00:35| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to\naccess resources."
},
{
"lang": "es",
"value": "CWE-610: Existe una vulnerabilidad de referencia controlada externamente a un recurso en otra esfera que podr\u00eda causar una p\u00e9rdida de confidencialidad cuando un atacante no autenticado manipula la URL del servidor web del controlador para acceder a los recursos."
}
],
"id": "CVE-2025-2875",
"lastModified": "2026-04-15T00:35:42.020",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2025-05-14T09:15:20.097",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-610"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-CJWM-R7H6-VPG7
Vulnerability from github – Published: 2025-05-14 09:30 – Updated: 2025-05-14 09:30CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.
{
"affected": [],
"aliases": [
"CVE-2025-2875"
],
"database_specific": {
"cwe_ids": [
"CWE-610"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-05-14T09:15:20Z",
"severity": "HIGH"
},
"details": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to\naccess resources.",
"id": "GHSA-cjwm-r7h6-vpg7",
"modified": "2025-05-14T09:30:25Z",
"published": "2025-05-14T09:30:25Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-2875"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-25-140-08
Vulnerability from csaf_cisa - Published: 2025-05-13 04:00 - Updated: 2025-10-14 07:00CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0015 | — | ||
| Unresolved product id: CSAFPID-0018 | — | ||
| Unresolved product id: CSAFPID-0019 | — | ||
| Unresolved product id: CSAFPID-0020 | — | ||
| Unresolved product id: CSAFPID-0021 | — | ||
| Unresolved product id: CSAFPID-0022 | — | ||
| Unresolved product id: CSAFPID-0016 | — | ||
| Unresolved product id: CSAFPID-0017 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Modicon Controllers M241 Versions prior to 5.3.12.48
Schneider Electric / Modicon Controllers M241
|
<5.3.12.48 |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modicon Controllers M251 Versions prior to 5.3.12.48
Schneider Electric / Modicon Controllers M251
|
<5.3.12.48 |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modicon Controllers M258 Versions prior to 5.0.4.19
Schneider Electric / Modicon Controllers M258
|
<5.0.4.19 |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modicon Controllers LMC058 Versions prior to 5.0.4.19
Schneider Electric / Modicon Controllers LMC058
|
<5.0.4.19 |
Vendor Fix
fix
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric CPCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its Modicon Controllers M241 / M251 / M258 / LMC058 products. \n\n The Modicon Controllers M241/M251/M258 https://www.se.com/ww/en/product-category/3900-plc-pac-and-dedicated-controllers/ and Modicon LMC058 https://www.se.com/ww/en/product-range/7744-modicon-lmc058/ products are Programmable Logic Controllers for performance-demanding applications. \n\n Failure to apply remediation/mitigations provided below may risk an unauthenticated read of arbitrary files which could result in loss of confidential data stored on the controller.\n\n July 2025 Update: A remediation is now available within EcoStruxure\u2122 Machine Expert v2.3 used to update the Modicon Controlers firmware.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0-https://www.first.org/cvss/calculator/4.0). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u2019s environment"
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch."
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-133-01 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "Modicon Controllers M241/M251/M258/LMC058 - SEVD-2025-133-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-133-01.json"
},
{
"category": "self",
"summary": "Modicon Controllers M241/M251/M258/LMC058 - SEVD-2025-133-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-140-08 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-140-08.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-140-08 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-140-08"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Schneider Electric Modicon Controllers (Update B)",
"tracking": {
"current_release_date": "2025-10-14T07:00:00.000000Z",
"generator": {
"date": "2025-10-21T13:58:09.411121Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-140-08",
"initial_release_date": "2025-05-13T04:00:00.000000Z",
"revision_history": [
{
"date": "2025-05-13T04:00:00.000000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-07-08T04:00:00.000000Z",
"number": "2.0.0",
"summary": "A remediation for M241/M251 is now available within \nEcoStruxure\u2122 Machine Expert v2.3 "
},
{
"date": "2025-10-14T07:00:00.000000Z",
"number": "3.0.0",
"summary": "A remediation is now available for Modicon M258 / LMC058"
}
],
"status": "final",
"version": "3.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.3.12.48",
"product": {
"name": "Modicon Controllers M241 Versions prior to 5.3.12.48",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M241"
},
{
"branches": [
{
"category": "product_version",
"name": "5.3.12.48",
"product": {
"name": "Modicon Controllers M241 5.3.12.48",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M241"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.3.12.48",
"product": {
"name": "Modicon Controllers M251 Versions prior to 5.3.12.48",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M251"
},
{
"branches": [
{
"category": "product_version",
"name": "5.3.12.48",
"product": {
"name": "Modicon Controllers M251 Version 5.3.12.48",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M251"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.0.4.19",
"product": {
"name": "Modicon Controllers M258 Versions prior to 5.0.4.19",
"product_id": "CSAFPID-0005"
}
},
{
"category": "product_version",
"name": "5.0.4.19",
"product": {
"name": "Modicon Controllers M258 Version 5.0.4.19",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M258"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.0.4.19",
"product": {
"name": "Modicon Controllers LMC058 Versions prior to 5.0.4.19",
"product_id": "CSAFPID-0007"
}
},
{
"category": "product_version",
"name": "5.0.4.19",
"product": {
"name": "Modicon Controllers LMC058 Version 5.0.4.19",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "Modicon Controllers LMC058"
},
{
"branches": [
{
"category": "product_version",
"name": "24.1",
"product": {
"name": "EcoStruxure\u2122 Automation Expert - Motion Version 24.1",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "EcoStruxure Automation Expert - Motion"
},
{
"branches": [
{
"category": "product_version",
"name": "2.3",
"product": {
"name": "EcoStruxure\u2122 Machine Expert 2.3",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "EcoStruxure Machine Expert"
},
{
"category": "product_name",
"name": "Modicon Controllers M258",
"product": {
"name": "Modicon Controllers M258",
"product_id": "CSAFPID-0011"
}
},
{
"category": "product_name",
"name": "Modicon Controllers M241",
"product": {
"name": "Modicon Controllers M241",
"product_id": "CSAFPID-0012"
}
},
{
"category": "product_name",
"name": "Modicon Controllers M251",
"product": {
"name": "Modicon Controllers M251",
"product_id": "CSAFPID-0013"
}
},
{
"category": "product_name",
"name": "Modicon Controllers LMC058",
"product": {
"name": "Modicon Controllers LMC058",
"product_id": "CSAFPID-0014"
}
}
],
"category": "vendor",
"name": "Schneider Electric"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M241 5.3.12.48 installed on EcoStruxure\u2122 Automation Expert - Motion Version 24.1",
"product_id": "CSAFPID-0015"
},
"product_reference": "CSAFPID-0002",
"relates_to_product_reference": "CSAFPID-0009"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M241 5.3.12.48 installed on Modicon Controllers M241",
"product_id": "CSAFPID-0016"
},
"product_reference": "CSAFPID-0002",
"relates_to_product_reference": "CSAFPID-0012"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M251 5.3.12.48 installed on Modicon Controllers M251",
"product_id": "CSAFPID-0017"
},
"product_reference": "CSAFPID-0004",
"relates_to_product_reference": "CSAFPID-0013"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M241 5.3.12.48 installed on EcoStruxure\u2122 Machine Expert 2.3",
"product_id": "CSAFPID-0018"
},
"product_reference": "CSAFPID-0002",
"relates_to_product_reference": "CSAFPID-0010"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M251 Version 5.3.12.48 installed on EcoStruxure\u2122 Automation Expert - Motion Version 24.1",
"product_id": "CSAFPID-0019"
},
"product_reference": "CSAFPID-0004",
"relates_to_product_reference": "CSAFPID-0009"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M251 Version 5.3.12.48 installed on EcoStruxure\u2122 Machine Expert 2.3",
"product_id": "CSAFPID-0020"
},
"product_reference": "CSAFPID-0004",
"relates_to_product_reference": "CSAFPID-0010"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M258 Firmware Version 5.0.4.19 installed on Modicon Controllers M258",
"product_id": "CSAFPID-0021"
},
"product_reference": "CSAFPID-0006",
"relates_to_product_reference": "CSAFPID-0011"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers LMC058 Firmware Version 5.0.4.19 installed on Modicon Controllers LMC058",
"product_id": "CSAFPID-0022"
},
"product_reference": "CSAFPID-0008",
"relates_to_product_reference": "CSAFPID-0014"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Loc Nguyen",
"Dat Phung",
"Thai Do",
"Minh Pham"
],
"organization": "Unit 515, OPSWAT"
}
],
"cve": "CVE-2025-2875",
"cwe": {
"id": "CWE-610",
"name": "Externally Controlled Reference to a Resource in Another Sphere"
},
"notes": [
{
"category": "description",
"text": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could \r\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to \r\naccess resources.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0015",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0016",
"CSAFPID-0017"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Versions 5.3.12.48 of Modicon Controllers M241 include a fix for this vulnerability and can be downloaded here: M241:https://www.se.com/ww/en/product-range/62129-modicon-m241-micro-plc/#software-and-firmware \n\n* Use the Controller Assistant feature of EcoStruxure\u2122 Automation Expert - Motion V24.1 or EcoStruxure\u2122 Machine Expert V2.3 to update the M241/M251 firmware and perform a reboot.\n\n* EcoStruxure\u2122 Automation Expert - Motion V24.1 and EcoStruxure\u2122 Machine Expert V2.3 are available via the Schneider Electric Software Installer: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER \n\n* Additional information is available in the Quick Start Guide, chapter \u201cEcoStruxure\u2122 Automation Expert Platform Installation\u201d.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/62129-modicon-m241-micro-plc/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Versions 5.3.12.48 of Modicon Controllers M251 include a fix for this vulnerability and can be downloaded here: M251:https://www.se.com/ww/en/product-range/62130-modicon-m251-micro-plc-with-dual-channel-comm/#software-and-firmware \n\n* Use the Controller Assistant feature of EcoStruxure\u2122 Automation Expert - Motion V24.1 or EcoStruxure\u2122 Machine Expert V2.3 to update the M241/M251 firmware and perform a reboot.\n\n* EcoStruxure\u2122 Automation Expert - Motion V24.1 and EcoStruxure\u2122 Machine Expert V2.3 are available via the Schneider Electric Software Installer: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER \n\n* Additional information is available in the Quick Start Guide, chapter \u201cEcoStruxure\u2122 Automation Expert Platform Installation\u201d.",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/62130-modicon-m251-micro-plc-with-dual-channel-comm/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Modicon M258/LMC058 Firmware version 5.0.4.19 includes a fix for this vulnerability and can be downloaded here: https://www.se.com/ww/en/product-range/2730-modicon-m258-compact-plc-for-machine-automation/#software-and-firmware By using Controller Assistant from EcoStruxureTM Machine Expert update Modicon Controller M258/LMC058 and perform reboot.",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2730-modicon-m258-compact-plc-for-machine-automation/#software-and-firmware"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Use controllers and devices only in a protected environment to \r\nminimize network exposure and ensure that they are not \r\naccessible from public internet or untrusted networks.\r\n\u2022 Ensure usage of user management and password features. User \r\nrights are enabled by default and forced to create a strong \r\npassword at first use.\r\n\u2022 Deactivate the Webserver after use when not needed. \r\n\u2022 Use encrypted communication links when available. \r\n\u2022 Setup network segmentation and implement a firewall to block all \r\nunauthorized access to ports 80/HTTP and 443/HTTPS. \r\n\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required.\r\n\u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, \r\nModicon and PacDrive Controllers and Associated Equipment\u201d provide product specific hardening guidelines.\r\n\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: \r\nhttps://www.se.com/en/work/support/cybersecurity/security\u0002notifications.jsp",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=User+guide\u0026p_File_Name=EIO0000004242.00.pdf\u0026p_Doc_Ref=EIO0000004242"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007"
]
}
],
"title": "CVE-2025-2875"
}
]
}
SEVD-2025-133-01
Vulnerability from csaf_se - Published: 2025-05-13 04:00 - Updated: 2025-10-14 07:00CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: 9 | — | ||
| Unresolved product id: 10 | — | ||
| Unresolved product id: 11 | — | ||
| Unresolved product id: 12 | — | ||
| Unresolved product id: 17 | — | ||
| Unresolved product id: 18 | — | ||
| Unresolved product id: 21 | — | ||
| Unresolved product id: 22 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Modicon Controllers M241 Versions prior to 5.3.12.48
Schneider Electric / Modicon Controllers M241
|
<5.3.12.48 |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modicon Controllers M251 Versions prior to 5.3.12.48
Schneider Electric / Modicon Controllers M251
|
<5.3.12.48 |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modicon Controllers M258 Versions prior to 5.0.4.19
Schneider Electric / Modicon Controllers M258
|
<5.0.4.19 |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modicon Controllers LMC058 Versions prior to 5.0.4.19
Schneider Electric / Modicon Controllers LMC058
|
<5.0.4.19 |
Vendor Fix
fix
Mitigation
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its Modicon Controllers M241 / M251 / M258 / LMC058 products. \n\n The Modicon Controllers M241/M251/M258 https://www.se.com/ww/en/product-category/3900-plc-pac-and-dedicated-controllers/ and Modicon LMC058 https://www.se.com/ww/en/product-range/7744-modicon-lmc058/ products are Programmable Logic Controllers for performance-demanding applications. \n\n Failure to apply remediation/mitigations provided below may risk an unauthenticated read of arbitrary files which could result in loss of confidential data stored on the controller.\n\n July 2025 Update: A remediation is now available within EcoStruxure\u2122 Machine Expert v2.3 used to update the Modicon Controlers firmware.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0-https://www.first.org/cvss/calculator/4.0). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u2019s environment"
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch."
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Modicon Controllers M241/M251/M258/LMC058 - SEVD-2025-133-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-133-01.pdf"
},
{
"category": "self",
"summary": "Modicon Controllers M241/M251/M258/LMC058 - SEVD-2025-133-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-133-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-133-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Modicon Controllers M241/M251/M258/LMC058",
"tracking": {
"current_release_date": "2025-10-14T07:00:00.000Z",
"generator": {
"date": "2025-10-07T03:22:58.107Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2025-133-01",
"initial_release_date": "2025-05-13T04:00:00.000Z",
"revision_history": [
{
"date": "2025-05-13T04:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-07-08T04:00:00.000Z",
"number": "2.0.0",
"summary": "A remediation for M241/M251 is now available within \nEcoStruxure\u2122 Machine Expert v2.3 "
},
{
"date": "2025-10-14T07:00:00.000Z",
"number": "3.0.0",
"summary": "A remediation is now available for Modicon M258 / LMC058"
}
],
"status": "final",
"version": "3.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.3.12.48",
"product": {
"name": "Modicon Controllers M241 Versions prior to 5.3.12.48",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M241"
},
{
"branches": [
{
"category": "product_version",
"name": "5.3.12.48",
"product": {
"name": "Modicon Controllers M241 5.3.12.48",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M241"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.3.12.48",
"product": {
"name": "Modicon Controllers M251 Versions prior to 5.3.12.48",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M251"
},
{
"branches": [
{
"category": "product_version",
"name": "5.3.12.48",
"product": {
"name": "Modicon Controllers M251 Version 5.3.12.48",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M251"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.0.4.19",
"product": {
"name": "Modicon Controllers M258 Versions prior to 5.0.4.19",
"product_id": "5"
}
},
{
"category": "product_version",
"name": "5.0.4.19",
"product": {
"name": "Modicon Controllers M258 Version 5.0.4.19",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "Modicon Controllers M258"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.0.4.19",
"product": {
"name": "Modicon Controllers LMC058 Versions prior to 5.0.4.19",
"product_id": "6"
}
},
{
"category": "product_version",
"name": "5.0.4.19",
"product": {
"name": "Modicon Controllers LMC058 Version 5.0.4.19",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "Modicon Controllers LMC058"
},
{
"branches": [
{
"category": "product_version",
"name": "24.1",
"product": {
"name": "EcoStruxure\u2122 Automation Expert - Motion Version 24.1",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "EcoStruxure Automation Expert - Motion"
},
{
"branches": [
{
"category": "product_version",
"name": "2.3",
"product": {
"name": "EcoStruxure\u2122 Machine Expert 2.3",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "EcoStruxure Machine Expert"
},
{
"category": "product_name",
"name": "Modicon Controllers M258",
"product": {
"name": "Modicon Controllers M258",
"product_id": "15"
}
},
{
"category": "product_name",
"name": "Modicon Controllers M241",
"product": {
"name": "Modicon Controllers M241",
"product_id": "19"
}
},
{
"category": "product_name",
"name": "Modicon Controllers M251",
"product": {
"name": "Modicon Controllers M251",
"product_id": "20"
}
},
{
"category": "product_name",
"name": "Modicon Controllers LMC058",
"product": {
"name": "Modicon Controllers LMC058",
"product_id": "16"
}
}
],
"category": "vendor",
"name": "Schneider Electric"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M241 5.3.12.48 installed on EcoStruxure\u2122 Automation Expert - Motion Version 24.1",
"product_id": "9"
},
"product_reference": "2",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M241 5.3.12.48 installed on Modicon Controllers M241",
"product_id": "21"
},
"product_reference": "2",
"relates_to_product_reference": "19"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M251 5.3.12.48 installed on Modicon Controllers M251",
"product_id": "22"
},
"product_reference": "4",
"relates_to_product_reference": "20"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M241 5.3.12.48 installed on EcoStruxure\u2122 Machine Expert 2.3",
"product_id": "10"
},
"product_reference": "2",
"relates_to_product_reference": "8"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M251 Version 5.3.12.48 installed on EcoStruxure\u2122 Automation Expert - Motion Version 24.1",
"product_id": "11"
},
"product_reference": "4",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M251 Version 5.3.12.48 installed on EcoStruxure\u2122 Machine Expert 2.3",
"product_id": "12"
},
"product_reference": "4",
"relates_to_product_reference": "8"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers M258 Firmware Version 5.0.4.19 installed on Modicon Controllers M258",
"product_id": "17"
},
"product_reference": "13",
"relates_to_product_reference": "15"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon Controllers LMC058 Firmware Version 5.0.4.19 installed on Modicon Controllers LMC058",
"product_id": "18"
},
"product_reference": "14",
"relates_to_product_reference": "16"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Loc Nguyen",
"Dat Phung",
"Thai Do",
"Minh Pham"
],
"organization": "Unit 515, OPSWAT"
}
],
"cve": "CVE-2025-2875",
"cwe": {
"id": "CWE-610",
"name": "Externally Controlled Reference to a Resource in Another Sphere"
},
"notes": [
{
"category": "description",
"text": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could \r\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller\u2019s webserver URL to \r\naccess resources.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"9",
"10",
"11",
"12",
"17",
"18",
"21",
"22"
],
"known_affected": [
"1",
"3",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Versions 5.3.12.48 of Modicon Controllers M241 include a fix for this vulnerability and can be downloaded here: M241:https://www.se.com/ww/en/product-range/62129-modicon-m241-micro-plc/#software-and-firmware \n\n* Use the Controller Assistant feature of EcoStruxure\u2122 Automation Expert - Motion V24.1 or EcoStruxure\u2122 Machine Expert V2.3 to update the M241/M251 firmware and perform a reboot.\n\n* EcoStruxure\u2122 Automation Expert - Motion V24.1 and EcoStruxure\u2122 Machine Expert V2.3 are available via the Schneider Electric Software Installer: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER \n\n* Additional information is available in the Quick Start Guide, chapter \u201cEcoStruxure\u2122 Automation Expert Platform Installation\u201d.",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/62129-modicon-m241-micro-plc/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Versions 5.3.12.48 of Modicon Controllers M251 include a fix for this vulnerability and can be downloaded here: M251:https://www.se.com/ww/en/product-range/62130-modicon-m251-micro-plc-with-dual-channel-comm/#software-and-firmware \n\n* Use the Controller Assistant feature of EcoStruxure\u2122 Automation Expert - Motion V24.1 or EcoStruxure\u2122 Machine Expert V2.3 to update the M241/M251 firmware and perform a reboot.\n\n* EcoStruxure\u2122 Automation Expert - Motion V24.1 and EcoStruxure\u2122 Machine Expert V2.3 are available via the Schneider Electric Software Installer: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER \n\n* Additional information is available in the Quick Start Guide, chapter \u201cEcoStruxure\u2122 Automation Expert Platform Installation\u201d.",
"product_ids": [
"3"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/62130-modicon-m251-micro-plc-with-dual-channel-comm/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Modicon M258/LMC058 Firmware version 5.0.4.19 includes a fix for this vulnerability and can be downloaded here: https://www.se.com/ww/en/product-range/2730-modicon-m258-compact-plc-for-machine-automation/#software-and-firmware By using Controller Assistant from EcoStruxureTM Machine Expert update Modicon Controller M258/LMC058 and perform reboot.",
"product_ids": [
"5",
"6"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2730-modicon-m258-compact-plc-for-machine-automation/#software-and-firmware"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Use controllers and devices only in a protected environment to \r\nminimize network exposure and ensure that they are not \r\naccessible from public internet or untrusted networks.\r\n\u2022 Ensure usage of user management and password features. User \r\nrights are enabled by default and forced to create a strong \r\npassword at first use.\r\n\u2022 Deactivate the Webserver after use when not needed. \r\n\u2022 Use encrypted communication links when available. \r\n\u2022 Setup network segmentation and implement a firewall to block all \r\nunauthorized access to ports 80/HTTP and 443/HTTPS. \r\n\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required.\r\n\u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, \r\nModicon and PacDrive Controllers and Associated Equipment\u201d provide product specific hardening guidelines.\r\n\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: \r\nhttps://www.se.com/en/work/support/cybersecurity/security\u0002notifications.jsp",
"product_ids": [
"1",
"3",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=User+guide\u0026p_File_Name=EIO0000004242.00.pdf\u0026p_Doc_Ref=EIO0000004242"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1",
"3",
"5",
"6"
]
}
],
"title": "CVE-2025-2875"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.