SSA-524778
Vulnerability from csaf_siemens - Published: 2023-10-10 00:00 - Updated: 2023-10-10 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Parasolid V35.0
Siemens / Parasolid V35.0
|
<V35.0.262 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.1
Siemens / Parasolid V35.1
|
<V35.1.250 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V36.0
Siemens / Parasolid V36.0
|
<V36.0.169 |
Mitigation
Vendor Fix
fix
|
|
|
Tecnomatix Plant Simulation V2201
Siemens / Tecnomatix Plant Simulation V2201
|
<V2201.0009 |
Mitigation
Vendor Fix
fix
|
|
|
Tecnomatix Plant Simulation V2302
Siemens / Tecnomatix Plant Simulation V2302
|
<V2302.0003 |
Mitigation
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens Tecnomatix Plant Simulation contains multiple vulnerabilities that could be triggered when the application reads SPP and IGS files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host system.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-524778: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-524778.html"
},
{
"category": "self",
"summary": "SSA-524778: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-524778.json"
},
{
"category": "self",
"summary": "SSA-524778: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
},
{
"category": "self",
"summary": "SSA-524778: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-524778.txt"
}
],
"title": "SSA-524778: File Parsing Vulnerabilities in Tecnomatix Plant Simulation",
"tracking": {
"current_release_date": "2023-10-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-524778",
"initial_release_date": "2023-10-10T00:00:00Z",
"revision_history": [
{
"date": "2023-10-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV35.0.262",
"product": {
"name": "Parasolid V35.0",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Parasolid V35.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV35.1.250",
"product": {
"name": "Parasolid V35.1",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Parasolid V35.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV36.0.169",
"product": {
"name": "Parasolid V36.0",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Parasolid V36.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2201.0009",
"product": {
"name": "Tecnomatix Plant Simulation V2201",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Tecnomatix Plant Simulation V2201"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2302.0003",
"product": {
"name": "Tecnomatix Plant Simulation V2302",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Tecnomatix Plant Simulation V2302"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-44081",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44081"
},
{
"cve": "CVE-2023-44082",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44082"
},
{
"cve": "CVE-2023-44083",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44083"
},
{
"cve": "CVE-2023-44084",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44084"
},
{
"cve": "CVE-2023-44085",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44085"
},
{
"cve": "CVE-2023-44086",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44086"
},
{
"cve": "CVE-2023-44087",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-44087"
},
{
"cve": "CVE-2023-45204",
"cwe": {
"id": "CWE-704",
"name": "Incorrect Type Conversion or Cast"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain a type confusion vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21268)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"4",
"5"
]
}
],
"title": "CVE-2023-45204"
},
{
"cve": "CVE-2023-45601",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted SPP or IGS files from unknown sources",
"product_ids": [
"1",
"2",
"3",
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0009 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0003 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.262 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/en-US/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.250 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/en-US/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V36.0.169 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/en-US/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5"
]
}
],
"title": "CVE-2023-45601"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.