CVE-2017-9629 (GCVE-0-2017-9629)
Vulnerability from cvelistv5 – Published: 2017-07-07 17:00 – Updated: 2024-08-05 17:11
VLAI?
Summary
A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Schneider Electric Wonderware ArchestrA Logger |
Affected:
Schneider Electric Wonderware ArchestrA Logger
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:11:02.286Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99488",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99488"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"
},
{
"name": "1038836",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038836"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Schneider Electric Wonderware ArchestrA Logger",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Schneider Electric Wonderware ArchestrA Logger"
}
]
}
],
"datePublic": "2017-07-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-11T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "99488",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99488"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"
},
{
"name": "1038836",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038836"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-9629",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric Wonderware ArchestrA Logger",
"version": {
"version_data": [
{
"version_value": "Schneider Electric Wonderware ArchestrA Logger"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99488",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99488"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"
},
{
"name": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/",
"refsource": "MISC",
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"
},
{
"name": "1038836",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038836"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-9629",
"datePublished": "2017-07-07T17:00:00",
"dateReserved": "2017-06-14T00:00:00",
"dateUpdated": "2024-08-05T17:11:02.286Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:wonderware_archestra_logger:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2017.426.2307.1\", \"matchCriteriaId\": \"44B2EAA7-1C85-43EC-BB4D-E2E3328A3BE1\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.\"}, {\"lang\": \"es\", \"value\": \"Un problema de buffer-overflow en la pila fue descubierto en Schneider Electric Wonderware ArchestrA Logger, en su versi\\u00f3n 2017.426.2307.1 y anteriores. La vulnerabilidad de buffer overflow basado en pila ha sido descubierta, lo que podr\\u00eda permitir a un atacante remoto ejecutar c\\u00f3digo aleatorio en el contexto de una cuenta con altos privilegios.\"}]",
"id": "CVE-2017-9629",
"lastModified": "2024-11-21T03:36:32.967",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2017-07-07T17:29:00.403",
"references": "[{\"url\": \"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/99488\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1038836\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/99488\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1038836\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2017-9629\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-07-07T17:29:00.403\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.\"},{\"lang\":\"es\",\"value\":\"Un problema de buffer-overflow en la pila fue descubierto en Schneider Electric Wonderware ArchestrA Logger, en su versi\u00f3n 2017.426.2307.1 y anteriores. La vulnerabilidad de buffer overflow basado en pila ha sido descubierta, lo que podr\u00eda permitir a un atacante remoto ejecutar c\u00f3digo aleatorio en el contexto de una cuenta con altos privilegios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:wonderware_archestra_logger:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2017.426.2307.1\",\"matchCriteriaId\":\"44B2EAA7-1C85-43EC-BB4D-E2E3328A3BE1\"}]}]}],\"references\":[{\"url\":\"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99488\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1038836\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99488\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1038836\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…