CVE-2018-3952 (GCVE-0-2018-3952)

Vulnerability from cvelistv5 – Published: 2018-09-07 15:00 – Updated: 2024-09-16 17:28
VLAI?
Summary
An exploitable code execution vulnerability exists in the connect functionality of NordVPN 6.14.28.0. A specially crafted configuration file can cause a privilege escalation, resulting in the execution of arbitrary commands with system privileges.
CWE
  • OS command injection
Assigner
References
Impacted products
Vendor Product Version
Talos NordVPN Affected: NordVPN 6.14.28.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T04:57:24.473Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105312",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105312"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NordVPN",
          "vendor": "Talos",
          "versions": [
            {
              "status": "affected",
              "version": "NordVPN 6.14.28.0"
            }
          ]
        }
      ],
      "datePublic": "2018-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable code execution vulnerability exists in the connect functionality of NordVPN 6.14.28.0. A specially crafted configuration file can cause a privilege escalation, resulting in the execution of arbitrary commands with system privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS command injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T18:06:50",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "105312",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105312"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2018-09-07T00:00:00",
          "ID": "CVE-2018-3952",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NordVPN",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "NordVPN 6.14.28.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Talos"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable code execution vulnerability exists in the connect functionality of NordVPN 6.14.28.0. A specially crafted configuration file can cause a privilege escalation, resulting in the execution of arbitrary commands with system privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS command injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105312",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105312"
            },
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2018-3952",
    "datePublished": "2018-09-07T15:00:00Z",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-09-16T17:28:50.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:nordvpn:nordvpn:6.14.28.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"225DDD0E-FC36-4B09-9A3D-8841BE9BF477\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An exploitable code execution vulnerability exists in the connect functionality of NordVPN 6.14.28.0. A specially crafted configuration file can cause a privilege escalation, resulting in the execution of arbitrary commands with system privileges.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad explotable de ejecuci\\u00f3n de c\\u00f3digo en la funcionalidad connect de NordVPN 6.14.28.0. Un archivo de configuraci\\u00f3n especialmente manipulado podr\\u00eda provocar un escalado de privilegios, lo que resulta en la ejecuci\\u00f3n de comandos arbitrarios con privilegios del sistema.\"}]",
      "id": "CVE-2018-3952",
      "lastModified": "2024-11-21T04:06:22.340",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.0, \"impactScore\": 6.0}], \"cvssMetricV30\": [{\"source\": \"talos-cna@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.0, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-09-07T15:29:01.017",
      "references": "[{\"url\": \"http://www.securityfocus.com/bid/105312\", \"source\": \"talos-cna@cisco.com\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622\", \"source\": \"talos-cna@cisco.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/105312\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
      "sourceIdentifier": "talos-cna@cisco.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-3952\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2018-09-07T15:29:01.017\",\"lastModified\":\"2024-11-21T04:06:22.340\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An exploitable code execution vulnerability exists in the connect functionality of NordVPN 6.14.28.0. A specially crafted configuration file can cause a privilege escalation, resulting in the execution of arbitrary commands with system privileges.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad explotable de ejecuci\u00f3n de c\u00f3digo en la funcionalidad connect de NordVPN 6.14.28.0. Un archivo de configuraci\u00f3n especialmente manipulado podr\u00eda provocar un escalado de privilegios, lo que resulta en la ejecuci\u00f3n de comandos arbitrarios con privilegios del sistema.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0}],\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:nordvpn:nordvpn:6.14.28.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"225DDD0E-FC36-4B09-9A3D-8841BE9BF477\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/105312\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/105312\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0622\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…