CVE-2018-7843 (GCVE-0-2018-7843)

Vulnerability from cvelistv5 – Published: 2019-05-22 19:58 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.
Severity ?
No CVSS data available.
CWE
  • Multiple Vulnerabilities
Assigner
Impacted products
Vendor Product Version
n/a Modicon M580 Modicon M340 Modicon Quantum Modicon Premium Affected: Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.598Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Multiple Vulnerabilities",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-10T16:06:06",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7843",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Multiple Vulnerabilities"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
              "refsource": "MISC",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
            },
            {
              "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738",
              "refsource": "MISC",
              "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7843",
    "datePublished": "2019-05-22T19:58:58",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-08-05T06:37:59.598Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D52D735D-8AB5-40FE-A83F-266977601571\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E876C738-ABF6-4864-98A6-1E06E96A0DF4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"05CBA9AD-ECB7-453F-8551-DD176FDE8043\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"138681A2-0146-492B-8E10-06849FC27C6E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"745CC7A7-70FB-4551-8EBF-600B7A6236D7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A9B7CEF7-B9BA-4923-808F-DA2931569EBB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"619CFD8D-9652-4AAB-AFC4-796B3F10F61F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F00936E2-E6EF-4ABF-8666-7D83BE424F42\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.\"}, {\"lang\": \"es\", \"value\": \"CWE-248: Existe una vulnerabilidad de Excepci\\u00f3n no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, lo que podr\\u00eda generar una Denegaci\\u00f3n de Servicio cuando se lee bloques de memoria con un tama\\u00f1o de datos no v\\u00e1lido o con un desplazamiento de datos no v\\u00e1lido en el controlador sobre protocolo Modbus.\"}]",
      "id": "CVE-2018-7843",
      "lastModified": "2024-11-21T04:12:51.810",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2019-05-22T20:29:01.590",
      "references": "[{\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-7843\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-05-22T20:29:01.590\",\"lastModified\":\"2024-11-21T04:12:51.810\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.\"},{\"lang\":\"es\",\"value\":\"CWE-248: Existe una vulnerabilidad de Excepci\u00f3n no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, lo que podr\u00eda generar una Denegaci\u00f3n de Servicio cuando se lee bloques de memoria con un tama\u00f1o de datos no v\u00e1lido o con un desplazamiento de datos no v\u00e1lido en el controlador sobre protocolo Modbus.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D52D735D-8AB5-40FE-A83F-266977601571\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E876C738-ABF6-4864-98A6-1E06E96A0DF4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05CBA9AD-ECB7-453F-8551-DD176FDE8043\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"138681A2-0146-492B-8E10-06849FC27C6E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"745CC7A7-70FB-4551-8EBF-600B7A6236D7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A9B7CEF7-B9BA-4923-808F-DA2931569EBB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"619CFD8D-9652-4AAB-AFC4-796B3F10F61F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F00936E2-E6EF-4ABF-8666-7D83BE424F42\"}]}]}],\"references\":[{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…