cve-2020-26080
Vulnerability from cvelistv5
Published
2020-11-18 17:40
Modified
2024-11-13 17:39
Summary
A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:49:06.995Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-26080",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:22:13.624381Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T17:39:03.072Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco IoT Field Network Director (IoT-FND)",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-11-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-18T17:40:46",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
        }
      ],
      "source": {
        "advisory": "cisco-sa-FND-UPWD-dCRPuQ78",
        "defect": [
          [
            "CSCvt45294"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-11-18T16:00:00",
          "ID": "CVE-2020-26080",
          "STATE": "PUBLIC",
          "TITLE": "Cisco IoT Field Network Director Improper Domain Access Control Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco IoT Field Network Director (IoT-FND)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "4.1",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-FND-UPWD-dCRPuQ78",
          "defect": [
            [
              "CSCvt45294"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-26080",
    "datePublished": "2020-11-18T17:40:46.724171Z",
    "dateReserved": "2020-09-24T00:00:00",
    "dateUpdated": "2024-11-13T17:39:03.072Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.6.1\", \"matchCriteriaId\": \"0D507A4F-4079-4B68-997E-88901E063348\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la funcionalidad user management de Cisco IoT Field Network Director (FND), podr\\u00eda permitir a un atacante remoto autenticado administrar la informaci\\u00f3n de los usuarios en diferentes dominios en un sistema afectado.\u0026#xa0;La vulnerabilidad es debido a un control de acceso inapropiado al dominio.\u0026#xa0;Un atacante podr\\u00eda explotar esta vulnerabilidad manipulando cargas \\u00fatiles JSON para apuntar a diferentes dominios en un sistema afectado.\u0026#xa0;Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante administrar la informaci\\u00f3n del usuario para usuarios en diferentes dominios en un sistema afectado\"}]",
      "id": "CVE-2020-26080",
      "lastModified": "2024-11-21T05:19:11.697",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"baseScore\": 4.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 1.4}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"baseScore\": 4.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:N/I:P/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2020-11-18T18:15:12.077",
      "references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "ykramarz@cisco.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-26080\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-11-18T18:15:12.077\",\"lastModified\":\"2024-11-21T05:19:11.697\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la funcionalidad user management de Cisco IoT Field Network Director (FND), podr\u00eda permitir a un atacante remoto autenticado administrar la informaci\u00f3n de los usuarios en diferentes dominios en un sistema afectado.\u0026#xa0;La vulnerabilidad es debido a un control de acceso inapropiado al dominio.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad manipulando cargas \u00fatiles JSON para apuntar a diferentes dominios en un sistema afectado.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante administrar la informaci\u00f3n del usuario para usuarios en diferentes dominios en un sistema afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\",\"baseScore\":4.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":1.4}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\",\"baseScore\":4.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:P/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.6.1\",\"matchCriteriaId\":\"0D507A4F-4079-4B68-997E-88901E063348\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T15:49:06.995Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-26080\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-13T17:22:13.624381Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-13T17:25:57.512Z\"}}], \"cna\": {\"title\": \"Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"source\": {\"defect\": [[\"CSCvt45294\"]], \"advisory\": \"cisco-sa-FND-UPWD-dCRPuQ78\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 4.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco IoT Field Network Director (IoT-FND)\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2020-11-18T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2020-11-18T17:40:46\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"4.1\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\"}}, \"source\": {\"defect\": [[\"CSCvt45294\"]], \"advisory\": \"cisco-sa-FND-UPWD-dCRPuQ78\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco IoT Field Network Director (IoT-FND)\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-284\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-26080\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2020-11-18T16:00:00\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2020-26080\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-13T17:39:03.072Z\", \"dateReserved\": \"2020-09-24T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2020-11-18T17:40:46.724171Z\", \"assignerShortName\": \"cisco\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.