cve-2020-3558
Vulnerability from cvelistv5
Published
2020-10-21 18:41
Modified
2024-09-16 20:22
Summary
Cisco Firepower Management Center Software Open Redirect Vulnerability
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T07:37:55.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20201021 Cisco Firepower Management Center Software Open Redirect Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Firepower Management Center",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-10-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting an HTTP request from a user. A successful exploit could allow the attacker to modify the HTTP request to cause the interface to redirect the user to a specific, malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-10-21T18:41:19",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20201021 Cisco Firepower Management Center Software Open Redirect Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn"
        }
      ],
      "source": {
        "advisory": "cisco-sa-fmc-redirect-NYDuSEQn",
        "defect": [
          [
            "CSCvs71766"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Firepower Management Center Software Open Redirect Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-10-21T16:00:00",
          "ID": "CVE-2020-3558",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Firepower Management Center Software Open Redirect Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Firepower Management Center",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting an HTTP request from a user. A successful exploit could allow the attacker to modify the HTTP request to cause the interface to redirect the user to a specific, malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "4.7",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-601"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20201021 Cisco Firepower Management Center Software Open Redirect Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-fmc-redirect-NYDuSEQn",
          "defect": [
            [
              "CSCvs71766"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-3558",
    "datePublished": "2020-10-21T18:41:19.253965Z",
    "dateReserved": "2019-12-12T00:00:00",
    "dateUpdated": "2024-09-16T20:22:07.067Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-3558\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-10-21T19:15:17.700\",\"lastModified\":\"2023-11-07T03:22:54.773\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting an HTTP request from a user. A successful exploit could allow the attacker to modify the HTTP request to cause the interface to redirect the user to a specific, malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web de Cisco Firepower Management Center (FMC) Software, podr\u00eda permitir a un atacante remoto no autenticado redireccionar a un usuario a una p\u00e1gina web maliciosa.\u0026#xa0;La vulnerabilidad es debido a una comprobaci\u00f3n de entrada inapropiada de los par\u00e1metros de una petici\u00f3n HTTP.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad al interceptar una petici\u00f3n HTTP de un usuario.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir a un atacante modificar la petici\u00f3n HTTP para causar que la interfaz redireccione al usuario hacia una URL maliciosa espec\u00edfica.\u0026#xa0;Este tipo de vulnerabilidad se conoce como ataque de redireccionamiento abierto y se utiliza en ataques de phishing que hacen que los usuarios visiten sitios maliciosos sin saberlo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.3.16\",\"matchCriteriaId\":\"5B01F973-B364-4F40-8D4A-CBB60A68BD1E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.3.0\",\"versionEndIncluding\":\"6.3.0.5\",\"matchCriteriaId\":\"0AD39938-77FE-4CC2-A8FF-96EB92B70FC2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.0.9\",\"matchCriteriaId\":\"008A30E8-A96F-4614-8C40-DFCD2016AD9F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5.0\",\"versionEndIncluding\":\"6.5.0.4\",\"matchCriteriaId\":\"F8A6E625-0452-4B10-996C-7252B8CE2A3A\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.