Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.
Severity ?
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Triconex Model 3009 MP installed on Tricon V11.3.x systems |
Affected:
Triconex Model 3009 MP installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:42",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22747",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"version": {
"version_data": [
{
"version_value": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22747",
"datePublished": "2021-05-26T19:20:42",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.339Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:triconex_model_3009_mp_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.3.0\", \"versionEndExcluding\": \"11.8.0\", \"matchCriteriaId\": \"507557DF-0EBA-4203-8F5C-924E4EEEF29F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:triconex_model_3009_mp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9AD3F98C-C157-4737-A1B8-CC13252E7D24\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:tcm_4351b_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.3.0\", \"versionEndExcluding\": \"11.5.1\", \"matchCriteriaId\": \"E12A07EB-7CF9-4CB1-AAFE-D3559F6EF9F1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:tcm_4351b_firmware:11.7.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"73044D19-DBC2-490D-B6F8-714A8C846624\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:tcm_4351b:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9779F47B-29FB-4F09-854D-FEEFD4692A37\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.\"}, {\"lang\": \"es\", \"value\": \"Se presenta una vulnerabilidad de Comprobaci\\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en Triconex Model 3009 MP instalado en sistemas Tricon versi\\u00f3n V11.3.x, que podr\\u00eda causar el reinicio del m\\u00f3dulo cuando el TCM recibe paquetes TriStation malformados mientras el interruptor de llave de protecci\\u00f3n contra escritura est\\u00e1 en la posici\\u00f3n de programa.\u0026#xa0;Este ID de CVE es diferente de CVE-2021-22742, CVE-2021-22744, CVE-2021-22745 y CVE-2021-22746\"}]",
"id": "CVE-2021-22747",
"lastModified": "2024-11-21T05:50:35.167",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 3.9, \"baseSeverity\": \"LOW\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.3, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 2.1, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.9, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-05-26T20:15:09.457",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-754\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22747\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-05-26T20:15:09.457\",\"lastModified\":\"2024-11-21T05:50:35.167\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en Triconex Model 3009 MP instalado en sistemas Tricon versi\u00f3n V11.3.x, que podr\u00eda causar el reinicio del m\u00f3dulo cuando el TCM recibe paquetes TriStation malformados mientras el interruptor de llave de protecci\u00f3n contra escritura est\u00e1 en la posici\u00f3n de programa.\u0026#xa0;Este ID de CVE es diferente de CVE-2021-22742, CVE-2021-22744, CVE-2021-22745 y CVE-2021-22746\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":3.9,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.3,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:triconex_model_3009_mp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.3.0\",\"versionEndExcluding\":\"11.8.0\",\"matchCriteriaId\":\"507557DF-0EBA-4203-8F5C-924E4EEEF29F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:triconex_model_3009_mp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9AD3F98C-C157-4737-A1B8-CC13252E7D24\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tcm_4351b_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.3.0\",\"versionEndExcluding\":\"11.5.1\",\"matchCriteriaId\":\"E12A07EB-7CF9-4CB1-AAFE-D3559F6EF9F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tcm_4351b_firmware:11.7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"73044D19-DBC2-490D-B6F8-714A8C846624\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tcm_4351b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9779F47B-29FB-4F09-854D-FEEFD4692A37\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…