cve-2021-44000
Vulnerability from cvelistv5
Published
2022-02-09 15:17
Modified
2024-08-04 04:10
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-22-335/ | Third Party Advisory, VDB Entry |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:10:17.128Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "JT2Go", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.0.7" } ] }, { "product": "Solid Edge SE2021", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c SE2021MP9" } ] }, { "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c SE2022MP1" } ] }, { "product": "Teamcenter Visualization V13.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1.0.9" } ] }, { "product": "Teamcenter Visualization V13.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.0.7" } ] }, { "product": "Teamcenter Visualization V13.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.3.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-14T09:21:26", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-44000", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2.0.7" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All versions \u003c SE2021MP9" } ] } }, { "product_name": "Solid Edge SE2022", "version": { "version_data": [ { "version_value": "All versions \u003c SE2022MP1" } ] } }, { "product_name": "Teamcenter Visualization V13.1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1.0.9" } ] } }, { "product_name": "Teamcenter Visualization V13.2", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2.0.7" } ] } }, { "product_name": "Teamcenter Visualization V13.3", "version": { "version_data": [ { "version_value": "All versions \u003c V13.3.0.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-44000", "datePublished": "2022-02-09T15:17:07", "dateReserved": "2021-11-18T00:00:00", "dateUpdated": "2024-08-04T04:10:17.128Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-44000\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-02-09T16:15:14.107\",\"lastModified\":\"2022-06-14T10:15:18.087\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.7), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP9), Solid Edge SE2022 (Todas las versiones anteriores a SE2022MP1), Teamcenter Visualization V13.1 (Todas las versiones anteriores a V13.1.0.9), Teamcenter Visualization V13.2 (Todas las versiones anteriores a V13.2.0.7), Teamcenter Visualization V13.3 (Todas las versiones anteriores a V13.3.0.1). El archivo plmxmlAdapterSE70.dll contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del b\u00fafer de longitud fija basado en la pila mientras analiza archivos PAR especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15053)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.7\",\"matchCriteriaId\":\"E41637A0-726E-43B9-82DA-624F3EF8DC27\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"756343AA-DB57-40F7-94FA-84BFCDEB6159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"82090774-D894-41C8-82F1-A48A8707E9BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4173D09-C317-45FF-ABA4-39E5592862F8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack8:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB31E019-AFE4-4FC7-8070-B685C9253F0E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"61866294-2060-457C-9CBE-8AEAF03973F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndExcluding\":\"13.2.0.7\",\"matchCriteriaId\":\"1D30E398-C114-447E-9D4F-8D30B94ACF42\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.3.0\",\"versionEndExcluding\":\"13.3.0.1\",\"matchCriteriaId\":\"E5D0F936-4ABA-4530-A915-39F7EEC42BE9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A817DDD3-A448-46FE-8232-21E307A677F9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-335/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.