CVE-2021-44000 (GCVE-0-2021-44000)

Vulnerability from cvelistv5 – Published: 2022-02-09 15:17 – Updated: 2024-08-04 04:10
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)
Severity ?
No CVSS data available.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:10:17.128Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.7"
            }
          ]
        },
        {
          "product": "Solid Edge SE2021",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c SE2021MP9"
            }
          ]
        },
        {
          "product": "Solid Edge SE2022",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c SE2022MP1"
            }
          ]
        },
        {
          "product": "Teamcenter Visualization V13.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter Visualization V13.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.7"
            }
          ]
        },
        {
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T09:21:26",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44000",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT2Go",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Solid Edge SE2021",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c SE2021MP9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Solid Edge SE2022",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c SE2022MP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter Visualization V13.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter Visualization V13.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter Visualization V13.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.3.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122: Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44000",
    "datePublished": "2022-02-09T15:17:07",
    "dateReserved": "2021-11-18T00:00:00",
    "dateUpdated": "2024-08-04T04:10:17.128Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"13.2.0.7\", \"matchCriteriaId\": \"E41637A0-726E-43B9-82DA-624F3EF8DC27\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\", \"matchCriteriaId\": \"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\", \"matchCriteriaId\": \"756343AA-DB57-40F7-94FA-84BFCDEB6159\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\", \"matchCriteriaId\": \"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\", \"matchCriteriaId\": \"82090774-D894-41C8-82F1-A48A8707E9BB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\", \"matchCriteriaId\": \"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\", \"matchCriteriaId\": \"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\", \"matchCriteriaId\": \"A4173D09-C317-45FF-ABA4-39E5592862F8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack8:*:*:*:*:*:*\", \"matchCriteriaId\": \"EB31E019-AFE4-4FC7-8070-B685C9253F0E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"61866294-2060-457C-9CBE-8AEAF03973F6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.2.0\", \"versionEndExcluding\": \"13.2.0.7\", \"matchCriteriaId\": \"1D30E398-C114-447E-9D4F-8D30B94ACF42\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.3.0\", \"versionEndExcluding\": \"13.3.0.1\", \"matchCriteriaId\": \"E5D0F936-4ABA-4530-A915-39F7EEC42BE9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A817DDD3-A448-46FE-8232-21E307A677F9\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.7), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP9), Solid Edge SE2022 (Todas las versiones anteriores a SE2022MP1), Teamcenter Visualization V13.1 (Todas las versiones anteriores a V13.1.0.9), Teamcenter Visualization V13.2 (Todas las versiones anteriores a V13.2.0.7), Teamcenter Visualization V13.3 (Todas las versiones anteriores a V13.3.0.1). El archivo plmxmlAdapterSE70.dll contiene una escritura fuera de l\\u00edmites m\\u00e1s all\\u00e1 del b\\u00fafer de longitud fija basado en la pila mientras analiza archivos PAR especialmente dise\\u00f1ados. Esto podr\\u00eda permitir a un atacante ejecutar c\\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15053)\"}]",
      "id": "CVE-2021-44000",
      "lastModified": "2024-11-21T06:30:10.943",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2022-02-09T16:15:14.107",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-335/\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-335/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-122\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-44000\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-02-09T16:15:14.107\",\"lastModified\":\"2024-11-21T06:30:10.943\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.7), Solid Edge SE2021 (All versions \u003c SE2021MP9), Solid Edge SE2022 (All versions \u003c SE2022MP1), Teamcenter Visualization V13.1 (All versions \u003c V13.1.0.9), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.7), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.7), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP9), Solid Edge SE2022 (Todas las versiones anteriores a SE2022MP1), Teamcenter Visualization V13.1 (Todas las versiones anteriores a V13.1.0.9), Teamcenter Visualization V13.2 (Todas las versiones anteriores a V13.2.0.7), Teamcenter Visualization V13.3 (Todas las versiones anteriores a V13.3.0.1). El archivo plmxmlAdapterSE70.dll contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del b\u00fafer de longitud fija basado en la pila mientras analiza archivos PAR especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15053)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.7\",\"matchCriteriaId\":\"E41637A0-726E-43B9-82DA-624F3EF8DC27\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"756343AA-DB57-40F7-94FA-84BFCDEB6159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"82090774-D894-41C8-82F1-A48A8707E9BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4173D09-C317-45FF-ABA4-39E5592862F8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack8:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB31E019-AFE4-4FC7-8070-B685C9253F0E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"61866294-2060-457C-9CBE-8AEAF03973F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndExcluding\":\"13.2.0.7\",\"matchCriteriaId\":\"1D30E398-C114-447E-9D4F-8D30B94ACF42\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.3.0\",\"versionEndExcluding\":\"13.3.0.1\",\"matchCriteriaId\":\"E5D0F936-4ABA-4530-A915-39F7EEC42BE9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A817DDD3-A448-46FE-8232-21E307A677F9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-335/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-335/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…