CVE-2022-22806 (GCVE-0-2022-22806)
Vulnerability from cvelistv5 – Published: 2022-03-09 19:30 – Updated: 2024-08-03 03:21
VLAI
Summary
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
Severity
No CVSS data available.
CWE
- CWE-294 - Authentication Bypass by Capture-replay
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | SmartConnect |
Affected:
SMT Series
Affected: SMC Series Affected: SMTL Series Affected: SCL Series Affected: SMX Series |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:49.161Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SmartConnect",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "SMT Series"
},
{
"status": "affected",
"version": "SMC Series"
},
{
"status": "affected",
"version": "SMTL Series"
},
{
"status": "affected",
"version": "SCL Series"
},
{
"status": "affected",
"version": "SMX Series"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-28T16:25:29.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-22806",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SmartConnect",
"version": {
"version_data": [
{
"version_value": "SMT Series"
},
{
"version_value": "SMC Series"
},
{
"version_value": "SMTL Series"
},
{
"version_value": "SCL Series"
},
{
"version_value": "SMX Series"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-294 Authentication Bypass by Capture-replay"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-22806",
"datePublished": "2022-03-09T19:30:17.000Z",
"dateReserved": "2022-01-07T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:21:49.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-22806",
"date": "2026-05-27",
"epss": "0.00226",
"percentile": "0.45282"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"04.5\", \"matchCriteriaId\": \"2C3EA55B-DB09-4124-A9D9-A92431C38D1F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"95C1E3D9-606B-4C57-A4E7-0A45C9D46332\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"04.2\", \"matchCriteriaId\": \"FFE2D844-ED18-44D3-9E75-4BB3082E4B51\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"154E788E-173C-4D16-A492-B61D39D420EF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"02.9\", \"matchCriteriaId\": \"AE693F05-B0A7-452D-94C6-D36E37ACF6CB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6B138EB4-6264-4BFA-B4C7-4B23FFA676B1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"02.5\", \"matchCriteriaId\": \"C2E0803A-637E-4BBA-B9D5-AB59EE122844\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4175BEC7-DA4D-4E19-A642-A5FC13D3598E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"02.5\", \"matchCriteriaId\": \"469F9813-DE0E-4752-91EB-FECC001C6825\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E8DC43CB-66C0-469B-AF87-0120D6280584\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"02.5\", \"matchCriteriaId\": \"22E4C951-876D-46F7-8CF4-D943464E8338\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9FB7E0EB-AF6D-4107-B343-50309E9DF03E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"03.1\", \"matchCriteriaId\": \"3E52A522-88D4-4B6A-83B4-C56C093C7F54\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"04C627CE-E3F8-4E3F-8B93-07C92AA21296\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"03.1\", \"matchCriteriaId\": \"6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9E1E7040-8123-483C-AE62-F190D83D0ADC\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)\"}, {\"lang\": \"es\", \"value\": \"Una CWE-294: se presenta una vulnerabilidad de Omisi\\u00f3n de la Autenticaci\\u00f3n Mediante Captura-repetici\\u00f3n que podr\\u00eda causar una conexi\\u00f3n no autenticada al SAI cuando se env\\u00eda una conexi\\u00f3n malformada. Producto afectado: Familia SmartConnect: Serie SMT (SMT Series ID=1015: UPS 04.5 y anteriores), Serie SMC (SMC Series ID=1018: UPS 04.2 y anteriores), Serie SMTL (SMTL Series ID=1026: UPS 02.9 y anteriores), Serie SCL (SCL Series ID=1029: UPS 02. 5 y anteriores / SCL Series ID=1030: UPS 02.5 y anteriores / SCL Series ID=1036: UPS 02.5 y anteriores / SCL Series ID=1037: UPS 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS 03.1 y anteriores)\"}]",
"id": "CVE-2022-22806",
"lastModified": "2024-11-21T06:47:28.950",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-03-09T20:15:08.510",
"references": "[{\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2022-067-02/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2022-067-02/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-294\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-294\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-22806\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-03-09T20:15:08.510\",\"lastModified\":\"2024-11-21T06:47:28.950\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-294: se presenta una vulnerabilidad de Omisi\u00f3n de la Autenticaci\u00f3n Mediante Captura-repetici\u00f3n que podr\u00eda causar una conexi\u00f3n no autenticada al SAI cuando se env\u00eda una conexi\u00f3n malformada. Producto afectado: Familia SmartConnect: Serie SMT (SMT Series ID=1015: UPS 04.5 y anteriores), Serie SMC (SMC Series ID=1018: UPS 04.2 y anteriores), Serie SMTL (SMTL Series ID=1026: UPS 02.9 y anteriores), Serie SCL (SCL Series ID=1029: UPS 02. 5 y anteriores / SCL Series ID=1030: UPS 02.5 y anteriores / SCL Series ID=1036: UPS 02.5 y anteriores / SCL Series ID=1037: UPS 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS 03.1 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"04.5\",\"matchCriteriaId\":\"2C3EA55B-DB09-4124-A9D9-A92431C38D1F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95C1E3D9-606B-4C57-A4E7-0A45C9D46332\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"04.2\",\"matchCriteriaId\":\"FFE2D844-ED18-44D3-9E75-4BB3082E4B51\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"154E788E-173C-4D16-A492-B61D39D420EF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"02.9\",\"matchCriteriaId\":\"AE693F05-B0A7-452D-94C6-D36E37ACF6CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B138EB4-6264-4BFA-B4C7-4B23FFA676B1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"02.5\",\"matchCriteriaId\":\"C2E0803A-637E-4BBA-B9D5-AB59EE122844\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4175BEC7-DA4D-4E19-A642-A5FC13D3598E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"02.5\",\"matchCriteriaId\":\"469F9813-DE0E-4752-91EB-FECC001C6825\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8DC43CB-66C0-469B-AF87-0120D6280584\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"02.5\",\"matchCriteriaId\":\"22E4C951-876D-46F7-8CF4-D943464E8338\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FB7E0EB-AF6D-4107-B343-50309E9DF03E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"03.1\",\"matchCriteriaId\":\"3E52A522-88D4-4B6A-83B4-C56C093C7F54\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04C627CE-E3F8-4E3F-8B93-07C92AA21296\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"03.1\",\"matchCriteriaId\":\"6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E1E7040-8123-483C-AE62-F190D83D0ADC\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2022-067-02/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2022-067-02/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…