A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site
Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the
webserver.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.183Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists on a DCE endpoint through the logging capabilities of the\nwebserver. \n\n\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\n\n\n\n\n\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists on a DCE endpoint through the logging capabilities of the\nwebserver. \n\n\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:38:01.298Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25553", "datePublished": "2023-04-18T20:38:01.298Z", "dateReserved": "2023-02-07T17:00:03.779Z", "dateUpdated": "2024-08-02T11:25:19.183Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.9.2\", \"matchCriteriaId\": \"9DCD63E5-0A70-47B2-9F4F-5328E0BD04B0\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\\nScripting\u0027) vulnerability exists on a DCE endpoint through the logging capabilities of the\\nwebserver. \\n\\n\\n\\n\\n\\n \\n\\n\\n\\n\\n \\n\\n \\n\\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\\n\\n\"}]", "id": "CVE-2023-25553", "lastModified": "2024-11-21T07:49:43.073", "metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}]}", "published": "2023-04-18T21:15:08.777", "references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2023-25553\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-04-18T21:15:08.777\",\"lastModified\":\"2024-11-21T07:49:43.073\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\\nScripting\u0027) vulnerability exists on a DCE endpoint through the logging capabilities of the\\nwebserver. \\n\\n\\n\\n\\n\\n \\n\\n\\n\\n\\n \\n\\n \\n\\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.9,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.9.2\",\"matchCriteriaId\":\"9DCD63E5-0A70-47B2-9F4F-5328E0BD04B0\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.