CVE-2023-32279 (GCVE-0-2023-32279)
Vulnerability from cvelistv5 – Published: 2023-11-14 19:04 – Updated: 2024-08-30 17:41
VLAI
Summary
Improper access control in user mode driver for some Intel(R) Connectivity Performance Suite before version 2.1123.214.2 may allow unauthenticated user to potentially enable information disclosure via network access.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Connectivity Performance Suite |
Affected:
before version 2.1123.214.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.411Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32279",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-30T17:40:34.016793Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-30T17:41:42.128Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Connectivity Performance Suite",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.1123.214.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in user mode driver for some Intel(R) Connectivity Performance Suite before version 2.1123.214.2 may allow unauthenticated user to potentially enable information disclosure via network access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en"
},
{
"cweId": "CWE-284",
"description": "Improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T19:04:39.018Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-32279",
"datePublished": "2023-11-14T19:04:39.018Z",
"dateReserved": "2023-05-06T03:00:04.365Z",
"dateUpdated": "2024-08-30T17:41:42.128Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-32279",
"date": "2026-06-08",
"epss": "0.0028",
"percentile": "0.51616"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:connectivity_performance_suite:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.1123.214.2\", \"matchCriteriaId\": \"F126F42C-E3C9-40F7-BA9D-E4CA2548C6AA\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper access control in user mode driver for some Intel(R) Connectivity Performance Suite before version 2.1123.214.2 may allow unauthenticated user to potentially enable information disclosure via network access.\"}, {\"lang\": \"es\", \"value\": \"El control de acceso inadecuado en el controlador del modo de usuario para Intel(R) Connectivity Performance Suite anteriores a la versi\\u00f3n 2.1123.214.2 puede permitir que un usuario no autenticado habilite potencialmente la divulgaci\\u00f3n de informaci\\u00f3n a trav\\u00e9s del acceso a la red.\"}]",
"id": "CVE-2023-32279",
"lastModified": "2024-11-21T08:03:01.910",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"secure@intel.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2023-11-14T19:15:25.480",
"references": "[{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"secure@intel.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-32279\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2023-11-14T19:15:25.480\",\"lastModified\":\"2024-11-21T08:03:01.910\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper access control in user mode driver for some Intel(R) Connectivity Performance Suite before version 2.1123.214.2 may allow unauthenticated user to potentially enable information disclosure via network access.\"},{\"lang\":\"es\",\"value\":\"El control de acceso inadecuado en el controlador del modo de usuario para Intel(R) Connectivity Performance Suite anteriores a la versi\u00f3n 2.1123.214.2 puede permitir que un usuario no autenticado habilite potencialmente la divulgaci\u00f3n de informaci\u00f3n a trav\u00e9s del acceso a la red.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"secure@intel.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"secure@intel.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:connectivity_performance_suite:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.1123.214.2\",\"matchCriteriaId\":\"F126F42C-E3C9-40F7-BA9D-E4CA2548C6AA\"}]}]}],\"references\":[{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\", \"name\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T15:10:24.411Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-32279\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-30T17:40:34.016793Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-30T17:41:36.768Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"Intel(R) Connectivity Performance Suite\", \"versions\": [{\"status\": \"affected\", \"version\": \"before version 2.1123.214.2\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\", \"name\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00944.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper access control in user mode driver for some Intel(R) Connectivity Performance Suite before version 2.1123.214.2 may allow unauthenticated user to potentially enable information disclosure via network access.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"information disclosure\"}, {\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"Improper access control\"}]}], \"providerMetadata\": {\"orgId\": \"6dda929c-bb53-4a77-a76d-48e79601a1ce\", \"shortName\": \"intel\", \"dateUpdated\": \"2023-11-14T19:04:39.018Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-32279\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-30T17:41:42.128Z\", \"dateReserved\": \"2023-05-06T03:00:04.365Z\", \"assignerOrgId\": \"6dda929c-bb53-4a77-a76d-48e79601a1ce\", \"datePublished\": \"2023-11-14T19:04:39.018Z\", \"assignerShortName\": \"intel\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…