cve-2023-38530
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:55.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.171",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:37.879Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38530",
    "datePublished": "2023-08-08T09:20:39.660Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:37.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-38530\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-08-08T10:15:16.220\",\"lastModified\":\"2024-06-11T12:15:11.777\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid V34.1 (Todas las versiones inferiores a V34.1.258), Parasolid V35.0 (Todas las versiones inferiores a V35.0.254), Parasolid V35.1 (Todas las versiones inferiores a V35.1. 171), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones inferiores a V14.3.0.3). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada al analizar archivos X_T especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual.\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.1\",\"versionEndExcluding\":\"34.1.258\",\"matchCriteriaId\":\"E7751190-C386-451B-88B5-4BB4DCBFCE44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.254\",\"matchCriteriaId\":\"0B5F1A02-44EB-45AA-B071-764B64473313\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.1\",\"versionEndExcluding\":\"35.1.171\",\"matchCriteriaId\":\"EA7FF725-2396-492A-8B97-CA77B4EFCC48\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.1\",\"versionEndExcluding\":\"14.1.0.11\",\"matchCriteriaId\":\"9EF3388B-D057-4DB9-96AE-B6F4678FE5B8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.2\",\"versionEndExcluding\":\"14.2.0.6\",\"matchCriteriaId\":\"7E1EFF45-5311-4E89-B736-271EF3C0C232\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.3\",\"versionEndExcluding\":\"14.3.0.3\",\"matchCriteriaId\":\"99F0D457-7D65-40DC-BCFA-339FA5648709\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-407785.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}