SSA-407785
Vulnerability from csaf_siemens - Published: 2023-08-08 00:00 - Updated: 2024-08-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Parasolid V34.1
Siemens / Parasolid V34.1
|
<V34.1.258 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.0
Siemens / Parasolid V35.0
|
<V35.0.254 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.1
Siemens / Parasolid V35.1
|
<V35.1.171 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter Visualization V14.1
Siemens / Teamcenter Visualization V14.1
|
<V14.1.0.11 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V14.2
Siemens / Teamcenter Visualization V14.2
|
<V14.2.0.6 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V14.3
Siemens / Teamcenter Visualization V14.3
|
<V14.3.0.3 |
Mitigation
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Parasolid V34.1
Siemens / Parasolid V34.1
|
<V34.1.258 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.0
Siemens / Parasolid V35.0
|
<V35.0.254 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter Visualization V14.1
Siemens / Teamcenter Visualization V14.1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Teamcenter Visualization V14.2
Siemens / Teamcenter Visualization V14.2
|
<V14.2.0.12 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V14.3
Siemens / Teamcenter Visualization V14.3
|
<V14.3.0.9 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V2312
Siemens / Teamcenter Visualization V2312
|
<V2312.0004 |
Mitigation
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Parasolid V34.1
Siemens / Parasolid V34.1
|
<V34.1.258 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.0
Siemens / Parasolid V35.0
|
<V35.0.254 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.1
Siemens / Parasolid V35.1
|
<V35.1.197 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.1
Siemens / Parasolid V35.1
|
<V35.1.184 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter Visualization V14.1
Siemens / Teamcenter Visualization V14.1
|
<V14.1.0.11 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V14.2
Siemens / Teamcenter Visualization V14.2
|
<V14.2.0.6 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V14.3
Siemens / Teamcenter Visualization V14.3
|
<V14.3.0.3 |
Mitigation
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Parasolid V34.1
Siemens / Parasolid V34.1
|
<V34.1.258 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.0
Siemens / Parasolid V35.0
|
<V35.0.254 |
Mitigation
Vendor Fix
fix
|
|
|
Parasolid V35.1
Siemens / Parasolid V35.1
|
<V35.1.184 |
Mitigation
Vendor Fix
fix
|
|
|
Teamcenter Visualization V14.1
Siemens / Teamcenter Visualization V14.1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Teamcenter Visualization V14.2
Siemens / Teamcenter Visualization V14.2
|
<V14.2.0.12 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V14.3
Siemens / Teamcenter Visualization V14.3
|
<V14.3.0.9 |
Mitigation
Vendor Fix
|
|
|
Teamcenter Visualization V2312
Siemens / Teamcenter Visualization V2312
|
<V2312.0004 |
Mitigation
Vendor Fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of service in the context of the current process.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-407785: Multiple X_T File Parsing Vulnerabilities in Parasolid and Teamcenter Visualization - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"category": "self",
"summary": "SSA-407785: Multiple X_T File Parsing Vulnerabilities in Parasolid and Teamcenter Visualization - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-407785.json"
}
],
"title": "SSA-407785: Multiple X_T File Parsing Vulnerabilities in Parasolid and Teamcenter Visualization",
"tracking": {
"current_release_date": "2024-08-13T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-407785",
"initial_release_date": "2023-08-08T00:00:00Z",
"revision_history": [
{
"date": "2023-08-08T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-11-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fixes for Teamcenter Visualization V14.1 and Teamcenter Visualization V14.3"
},
{
"date": "2024-06-11T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Corrected error regarding fix information for CVE-2023-38527, CVE-2023-38529 and CVE-2023-38531 for Teamcenter Visualization V14.1, Teamcenter Visualization V14.2 and Teamcenter Visualization V14.3 and added Teamcenter Visualization V2312. Corrected CVSSv3.1 vector of CVE-2023-38532. Added CVSSv4.0 vector to all CVEs"
},
{
"date": "2024-08-13T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix version for Teamcenter Visualization V14.2 for CVE-2023-38527, CVE-2023-38529, CVE-2023-38531"
}
],
"status": "interim",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV34.1.258",
"product": {
"name": "Parasolid V34.1",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Parasolid V34.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV35.0.254",
"product": {
"name": "Parasolid V35.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Parasolid V35.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV35.1.171",
"product": {
"name": "Parasolid V35.1",
"product_id": "3"
}
},
{
"category": "product_version_range",
"name": "\u003cV35.1.197",
"product": {
"name": "Parasolid V35.1",
"product_id": "4"
}
},
{
"category": "product_version_range",
"name": "\u003cV35.1.184",
"product": {
"name": "Parasolid V35.1",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Parasolid V35.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV14.1.0.11",
"product": {
"name": "Teamcenter Visualization V14.1",
"product_id": "6"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter Visualization V14.1",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V14.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV14.2.0.6",
"product": {
"name": "Teamcenter Visualization V14.2",
"product_id": "8"
}
},
{
"category": "product_version_range",
"name": "\u003cV14.2.0.12",
"product": {
"name": "Teamcenter Visualization V14.2",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V14.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV14.3.0.3",
"product": {
"name": "Teamcenter Visualization V14.3",
"product_id": "10"
}
},
{
"category": "product_version_range",
"name": "\u003cV14.3.0.9",
"product": {
"name": "Teamcenter Visualization V14.3",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V14.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2312.0004",
"product": {
"name": "Teamcenter Visualization V2312",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V2312"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-38524",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.1.0.11 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.6 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.3 or later version",
"product_ids": [
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.171 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"8",
"10"
]
}
],
"title": "CVE-2023-38524"
},
{
"cve": "CVE-2023-38525",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.1.0.11 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.6 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.3 or later version",
"product_ids": [
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.171 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"8",
"10"
]
}
],
"title": "CVE-2023-38525"
},
{
"cve": "CVE-2023-38526",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.1.0.11 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.6 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.3 or later version",
"product_ids": [
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.171 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"8",
"10"
]
}
],
"title": "CVE-2023-38526"
},
{
"cve": "CVE-2023-38527",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"7",
"9",
"11",
"12"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"7",
"9",
"11",
"12"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"7"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.12 or later version",
"product_ids": [
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.9 or later version",
"product_ids": [
"11"
]
},
{
"category": "vendor_fix",
"details": "Update to V2312.0004 or later version",
"product_ids": [
"12"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"7",
"9",
"11",
"12"
]
}
],
"title": "CVE-2023-38527"
},
{
"cve": "CVE-2023-38528",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"4",
"5",
"6",
"8",
"10"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"4",
"5",
"6",
"8",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.1.0.11 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.6 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.3 or later version",
"product_ids": [
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.184 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.197 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"4",
"5",
"6",
"8",
"10"
]
}
],
"title": "CVE-2023-38528"
},
{
"cve": "CVE-2023-38529",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"5",
"7",
"9",
"11",
"12"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"5",
"7",
"9",
"11",
"12"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"7"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.12 or later version",
"product_ids": [
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.9 or later version",
"product_ids": [
"11"
]
},
{
"category": "vendor_fix",
"details": "Update to V2312.0004 or later version",
"product_ids": [
"12"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.184 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"5",
"7",
"9",
"11",
"12"
]
}
],
"title": "CVE-2023-38529"
},
{
"cve": "CVE-2023-38530",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.1.0.11 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.6 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.3 or later version",
"product_ids": [
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.171 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"8",
"10"
]
}
],
"title": "CVE-2023-38530"
},
{
"cve": "CVE-2023-38531",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"5",
"7",
"9",
"11",
"12"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"5",
"7",
"9",
"11",
"12"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"7"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.12 or later version",
"product_ids": [
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.9 or later version",
"product_ids": [
"11"
]
},
{
"category": "vendor_fix",
"details": "Update to V2312.0004 or later version",
"product_ids": [
"12"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.184 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"5",
"7",
"9",
"11",
"12"
]
}
],
"title": "CVE-2023-38531"
},
{
"cve": "CVE-2023-38532",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted XT files in Parasolid or Teamcenter Visualization",
"product_ids": [
"1",
"2",
"3",
"6",
"8",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.1.0.11 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.2.0.6 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Update to V14.3.0.3 or later version",
"product_ids": [
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V34.1.258 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.0.254 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/258316782/"
},
{
"category": "vendor_fix",
"details": "Update to V35.1.171 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/258316782/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"8",
"10"
]
}
],
"title": "CVE-2023-38532"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.