CVE-2024-10387 (GCVE-0-2024-10387)

Vulnerability from cvelistv5 – Published: 2024-10-25 17:04 – Updated: 2024-10-25 20:14
VLAI?
Title
Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability
Summary
CVE-2024-10387 IMPACT A Denial-of-Service vulnerability exists in the affected product. The vulnerability could allow a threat actor with network access to send crafted messages to the device, potentially resulting in Denial-of-Service.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk ThinManager Affected: 11.2.0-11.2.9
Affected: 12.0.0-12.0.7
Affected: 12.1.0-12.1.8
Affected: 13.0.0-13.0.5
Affected: 13.1.0-13.1.3
Affected: 13.2.0-13.2.2
Affected: 14.0.0
Create a notification for this product.
Credits
Tenable Network Security
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "thinmanager",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThanOrEqual": "11.2.9",
                "status": "affected",
                "version": "11.2.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "12.0.7",
                "status": "affected",
                "version": "12.0.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "12.1.8",
                "status": "affected",
                "version": "12.1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.0.5",
                "status": "affected",
                "version": "13.0.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.1.3",
                "status": "affected",
                "version": "13.1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.2.2",
                "status": "affected",
                "version": "13.2.0",
                "versionType": "custom"
              },
              {
                "status": "affected",
                "version": "14.0.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10387",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:10:20.475990Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T20:14:03.121Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk ThinManager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "11.2.0-11.2.9"
            },
            {
              "status": "affected",
              "version": "12.0.0-12.0.7"
            },
            {
              "status": "affected",
              "version": "12.1.0-12.1.8"
            },
            {
              "status": "affected",
              "version": "13.0.0-13.0.5"
            },
            {
              "status": "affected",
              "version": "13.1.0-13.1.3"
            },
            {
              "status": "affected",
              "version": "13.2.0-13.2.2"
            },
            {
              "status": "affected",
              "version": "14.0.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Tenable Network Security"
        }
      ],
      "datePublic": "2024-10-25T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-10387 IMPACT\u003c/u\u003e\u003c/b\u003e\u003cu\u003e\u003c/u\u003e\u003c/p\u003e\n\n\u003cp\u003eA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service.\u003c/p\u003e"
            }
          ],
          "value": "CVE-2024-10387 IMPACT\n\n\n\nA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-129",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-129 Pointer Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-25T17:04:36.334Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: var(--wht);\"\u003eIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e11.2.10\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.0.8\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.1.9\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e13.0.6 \u003c/p\u003e\n\n\n\n\u003cp\u003e13.1.4 \u003c/p\u003e\n\n\n\n\u003cp\u003e13.2.3 \u003c/p\u003e\n\n\n\n\u003cp\u003e14.0.1\u003c/p\u003e\n\n\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "If able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\n\n\n11.2.10\n\n\n\n\n\n12.0.8\n\n\n\n\n\n12.1.9\n\n\n\n\n\n13.0.6 \n\n\n\n\n\n13.1.4 \n\n\n\n\n\n13.2.3 \n\n\n\n\n\n14.0.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\u003c/p\u003e\u003cp\u003eImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\u003c/p\u003e\n\n\n\n\u003cp\u003eFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best\npractices\u003c/a\u003e to\nminimize the risk of the vulnerability.\u003c/p\u003e"
            }
          ],
          "value": "If able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\nImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\n\n\n\n\n\nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested security best\npractices to\nminimize the risk of the vulnerability."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-10387",
    "datePublished": "2024-10-25T17:04:36.334Z",
    "dateReserved": "2024-10-25T12:38:30.428Z",
    "dateUpdated": "2024-10-25T20:14:03.121Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.2.0\", \"versionEndExcluding\": \"11.2.10\", \"matchCriteriaId\": \"AC6CF373-34C9-43AC-B210-2E7C31CEAEFA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"12.0.0\", \"versionEndExcluding\": \"12.0.8\", \"matchCriteriaId\": \"9EAE9FF9-28B3-4490-8358-A3636FFDC9C8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"12.1.0\", \"versionEndExcluding\": \"12.1.9\", \"matchCriteriaId\": \"667ACE9F-6074-4300-A90A-5C6F8A06B76A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.0.0\", \"versionEndExcluding\": \"13.0.6\", \"matchCriteriaId\": \"C56E6406-256A-4774-9FDD-E72625D4B1AA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.1.0\", \"versionEndIncluding\": \"13.1.4\", \"matchCriteriaId\": \"0305A358-81AA-468A-951D-98EE0C60695C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.2.0\", \"versionEndIncluding\": \"13.2.3\", \"matchCriteriaId\": \"4B920868-E568-44A7-9F68-B3D615956E12\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:thinmanager:14.0.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"48214ABF-9E29-4422-A0E6-6AF4AE199D51\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"CVE-2024-10387 IMPACT\\n\\n\\n\\nA Denial-of-Service\\nvulnerability exists in the affected product. The vulnerability could allow a\\nthreat actor with network access to send crafted messages to the device,\\npotentially resulting in Denial-of-Service.\"}, {\"lang\": \"es\", \"value\": \"CVE-2024-10387 IMPACTO Existe una vulnerabilidad de denegaci\\u00f3n de servicio en el producto afectado. La vulnerabilidad podr\\u00eda permitir que un actor de amenazas con acceso a la red env\\u00ede mensajes manipulados al dispositivo, lo que podr\\u00eda provocar una denegaci\\u00f3n de servicio.\"}]",
      "id": "CVE-2024-10387",
      "lastModified": "2024-11-05T20:05:55.323",
      "metrics": "{\"cvssMetricV40\": [{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"HIGH\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2024-10-25T17:15:04.230",
      "references": "[{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html\", \"source\": \"PSIRT@rockwellautomation.com\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Analyzed",
      "weaknesses": "[{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-10387\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-10-25T17:15:04.230\",\"lastModified\":\"2024-11-05T20:05:55.323\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CVE-2024-10387 IMPACT\\n\\n\\n\\nA Denial-of-Service\\nvulnerability exists in the affected product. The vulnerability could allow a\\nthreat actor with network access to send crafted messages to the device,\\npotentially resulting in Denial-of-Service.\"},{\"lang\":\"es\",\"value\":\"CVE-2024-10387 IMPACTO Existe una vulnerabilidad de denegaci\u00f3n de servicio en el producto afectado. La vulnerabilidad podr\u00eda permitir que un actor de amenazas con acceso a la red env\u00ede mensajes manipulados al dispositivo, lo que podr\u00eda provocar una denegaci\u00f3n de servicio.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.2.0\",\"versionEndExcluding\":\"11.2.10\",\"matchCriteriaId\":\"AC6CF373-34C9-43AC-B210-2E7C31CEAEFA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.0\",\"versionEndExcluding\":\"12.0.8\",\"matchCriteriaId\":\"9EAE9FF9-28B3-4490-8358-A3636FFDC9C8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.1.0\",\"versionEndExcluding\":\"12.1.9\",\"matchCriteriaId\":\"667ACE9F-6074-4300-A90A-5C6F8A06B76A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.0.0\",\"versionEndExcluding\":\"13.0.6\",\"matchCriteriaId\":\"C56E6406-256A-4774-9FDD-E72625D4B1AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.1.0\",\"versionEndIncluding\":\"13.1.4\",\"matchCriteriaId\":\"0305A358-81AA-468A-951D-98EE0C60695C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndIncluding\":\"13.2.3\",\"matchCriteriaId\":\"4B920868-E568-44A7-9F68-B3D615956E12\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:14.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48214ABF-9E29-4422-A0E6-6AF4AE199D51\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-10387\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-25T20:10:20.475990Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"thinmanager\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.2.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"11.2.9\"}, {\"status\": \"affected\", \"version\": \"12.0.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.7\"}, {\"status\": \"affected\", \"version\": \"12.1.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.1.8\"}, {\"status\": \"affected\", \"version\": \"13.0.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"13.0.5\"}, {\"status\": \"affected\", \"version\": \"13.1.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"13.1.3\"}, {\"status\": \"affected\", \"version\": \"13.2.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"13.2.2\"}, {\"status\": \"affected\", \"version\": \"14.0.0\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-25T20:13:42.749Z\"}}], \"cna\": {\"title\": \"Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Tenable Network Security\"}], \"impacts\": [{\"capecId\": \"CAPEC-129\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-129 Pointer Manipulation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"FactoryTalk ThinManager\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.2.0-11.2.9\"}, {\"status\": \"affected\", \"version\": \"12.0.0-12.0.7\"}, {\"status\": \"affected\", \"version\": \"12.1.0-12.1.8\"}, {\"status\": \"affected\", \"version\": \"13.0.0-13.0.5\"}, {\"status\": \"affected\", \"version\": \"13.1.0-13.1.3\"}, {\"status\": \"affected\", \"version\": \"13.2.0-13.2.2\"}, {\"status\": \"affected\", \"version\": \"14.0.0\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"If able,\\nnavigate to the  ThinManager\\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\\u00ae\\n\\n\\n\\n11.2.10\\n\\n\\n\\n\\n\\n12.0.8\\n\\n\\n\\n\\n\\n12.1.9\\n\\n\\n\\n\\n\\n13.0.6 \\n\\n\\n\\n\\n\\n13.1.4 \\n\\n\\n\\n\\n\\n13.2.3 \\n\\n\\n\\n\\n\\n14.0.1\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: var(--wht);\\\"\u003eIf able,\\nnavigate to the \u003c/span\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://thinmanager.com/downloads/\\\"\u003eThinManager\\u00ae download site\u003c/a\u003e\u003cspan style=\\\"background-color: var(--wht);\\\"\u003e and upgrade to a corrected version of ThinManager\\u00ae\u003c/span\u003e\\n\\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e11.2.10\u003cbr\u003e\\n\u003c/p\u003e\\n\\n\u003cp\u003e12.0.8\u003cbr\u003e\\n\u003c/p\u003e\\n\\n\u003cp\u003e12.1.9\u003cbr\u003e\\n\u003c/p\u003e\\n\\n\u003cp\u003e13.0.6 \u003c/p\u003e\\n\\n\\n\\n\u003cp\u003e13.1.4 \u003c/p\u003e\\n\\n\\n\\n\u003cp\u003e13.2.3 \u003c/p\u003e\\n\\n\\n\\n\u003cp\u003e14.0.1\u003c/p\u003e\\n\\n\\n\\n\\n\\n\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"datePublic\": \"2024-10-25T17:00:00.000Z\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"If able,\\nnavigate to the  ThinManager\\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\\u00ae\\n\\nImplement\\nnetwork hardening for ThinManager\\u00ae Device(s) by limiting communications to TCP\\n2031 to only the devices that need connection to the ThinManager\\u00ae\\n\\n\\n\\n\\n\\nFor\\ninformation on how to mitigate Security Risks on industrial automation control\\nsystems, we encourage customers to implement our suggested security best\\npractices to\\nminimize the risk of the vulnerability.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\u003cspan style=\\\"background-color: var(--wht);\\\"\u003eIf able,\\nnavigate to the \u003c/span\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://thinmanager.com/downloads/\\\"\u003eThinManager\\u00ae download site\u003c/a\u003e\u003cspan style=\\\"background-color: var(--wht);\\\"\u003e and upgrade to a corrected version of ThinManager\\u00ae\u003c/span\u003e\u003c/p\u003e\u003cp\u003eImplement\\nnetwork hardening for ThinManager\\u00ae Device(s) by limiting communications to TCP\\n2031 to only the devices that need connection to the ThinManager\\u00ae\u003c/p\u003e\\n\\n\\n\\n\u003cp\u003eFor\\ninformation on how to mitigate Security Risks on industrial automation control\\nsystems, we encourage customers to implement our suggested \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\\\"\u003esecurity best\\npractices\u003c/a\u003e to\\nminimize the risk of the vulnerability.\u003c/p\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CVE-2024-10387 IMPACT\\n\\n\\n\\nA Denial-of-Service\\nvulnerability exists in the affected product. The vulnerability could allow a\\nthreat actor with network access to send crafted messages to the device,\\npotentially resulting in Denial-of-Service.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-10387 IMPACT\u003c/u\u003e\u003c/b\u003e\u003cu\u003e\u003c/u\u003e\u003c/p\u003e\\n\\n\u003cp\u003eA Denial-of-Service\\nvulnerability exists in the affected product. The vulnerability could allow a\\nthreat actor with network access to send crafted messages to the device,\\npotentially resulting in Denial-of-Service.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125 Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2024-10-25T17:04:36.334Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-10387\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-25T20:14:03.121Z\", \"dateReserved\": \"2024-10-25T12:38:30.428Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2024-10-25T17:04:36.334Z\", \"assignerShortName\": \"Rockwell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…