cve-2024-36080
Vulnerability from cvelistv5
Published
Modified
2024-08-20 15:57
Severity ?
EPSS score ?
Summary
Westermo EDW-100 devices through 2024-05-03 have a hidden root user account with a hardcoded password that cannot be changed. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T03:30:12.997Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.westermo.com/-/media/Files/Cyber-security/westermo_sa_EDW-100_24-05.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:westernmo:edw_100:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "edw_100", "vendor": "westernmo", "versions": [ { "lessThanOrEqual": "2024_05_03", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-36080", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-20T15:52:17.256285Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284 Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-20T15:57:16.139Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Westermo EDW-100 devices through 2024-05-03 have a hidden root user account with a hardcoded password that cannot be changed. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-19T20:05:41.486104", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.westermo.com/-/media/Files/Cyber-security/westermo_sa_EDW-100_24-05.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-36080", "dateUpdated": "2024-08-20T15:57:16.139Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-36080\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-05-19T20:15:08.107\",\"lastModified\":\"2024-08-20T16:35:16.787\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Westermo EDW-100 devices through 2024-05-03 have a hidden root user account with a hardcoded password that cannot be changed. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network.\"},{\"lang\":\"es\",\"value\":\" Los dispositivos Westermo EDW-100 hasta el 3 de mayo de 2024 tienen una cuenta de usuario root oculta con una contrase\u00f1a codificada que no se puede cambiar. NOTA: este es un convertidor de serie a Ethernet que no debe colocarse en el borde de la red.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"references\":[{\"url\":\"https://www.westermo.com/-/media/Files/Cyber-security/westermo_sa_EDW-100_24-05.pdf\",\"source\":\"cve@mitre.org\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.