GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2025-0036 (GCVE-0-2025-0036)

Vulnerability from cvelistv5 – Published: 2025-06-09 23:57 – Updated: 2025-06-30 14:48
VLAI
Summary
In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-10 14:19 UTC
CWE
  • CWE-682 - Incorrect Calculation
  • CWE-772 - Missing Release of Resource after Effective Lifetime
  • CWE-940 - Improper Verification of Source of a Communication Channel
  • CWE-941 - Incorrectly Specified Destination in a Communication Channel
  • CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
Impacted products
Date Public
2025-06-03 16:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-0036",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-10T14:19:45.871057Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-10T15:27:43.315Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Versal Adaptive SoC Devices",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Versal RF Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Versal AI Edge Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Versal Prime Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Versal Premium Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Versal AI Core Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Versal HBM Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Alveo V80 Compute Accelerator",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "2025.1 release"
            }
          ]
        }
      ],
      "datePublic": "2025-06-03T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.\u003cbr\u003e"
            }
          ],
          "value": "In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-682",
              "description": "CWE-682 Incorrect Calculation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-772",
              "description": "CWE-772 Missing Release of Resource after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-940",
              "description": "CWE-940 Improper Verification of Source of a Communication Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-941",
              "description": "CWE-941 Incorrectly Specified Destination in a Communication Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-497",
              "description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-30T14:48:59.255Z",
        "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
        "shortName": "AMD"
      },
      "references": [
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8011.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
    "assignerShortName": "AMD",
    "cveId": "CVE-2025-0036",
    "datePublished": "2025-06-09T23:57:39.748Z",
    "dateReserved": "2024-11-21T16:18:02.918Z",
    "dateUpdated": "2025-06-30T14:48:59.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-0036",
      "date": "2026-09-15",
      "epss": "0.00146",
      "percentile": "0.0418"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-0036\",\"sourceIdentifier\":\"psirt@amd.com\",\"published\":\"2025-06-10T00:15:21.197\",\"lastModified\":\"2026-06-17T08:25:42.213\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.\"},{\"lang\":\"es\",\"value\":\"En los dispositivos SoC AMD Versal Adaptive, la configuraci\u00f3n incorrecta del SSS durante las operaciones criptogr\u00e1ficas en tiempo de ejecuci\u00f3n (post arranque) podr\u00eda provocar que los datos se escriban y lean incorrectamente desde ubicaciones no v\u00e1lidas, adem\u00e1s de devolver datos criptogr\u00e1ficos incorrectos.\"}],\"affected\":[{\"source\":\"psirt@amd.com\",\"affectedData\":[{\"vendor\":\"AMD\",\"product\":\"Versal Adaptive SoC Devices\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"versionType\":\"custom\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Versal RF Series\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Versal AI Edge Series\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Versal Prime Series\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Versal Premium Series\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Versal AI Core Series\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Versal HBM Series\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]},{\"vendor\":\"AMD\",\"product\":\"Alveo V80 Compute Accelerator\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"2025.1 release\",\"status\":\"unaffected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@amd.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:N\",\"baseScore\":3.2,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.5,\"impactScore\":1.4}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-06-10T14:19:45.871057Z\",\"id\":\"CVE-2025-0036\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"psirt@amd.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-497\"},{\"lang\":\"en\",\"value\":\"CWE-682\"},{\"lang\":\"en\",\"value\":\"CWE-772\"},{\"lang\":\"en\",\"value\":\"CWE-940\"},{\"lang\":\"en\",\"value\":\"CWE-941\"}]}],\"references\":[{\"url\":\"https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8011.html\",\"source\":\"psirt@amd.com\"}]}}",
    "redhat_vex": {
      "current_release_date": "2025-06-12T00:18:43+00:00",
      "cve": "CVE-2025-0036",
      "id": "CVE-2025-0036",
      "initial_release_date": "2025-06-03T16:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2025-0036",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-0036.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-0036\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-10T14:19:45.871057Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-10T14:19:47.545Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 3.2, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"AMD\", \"product\": \"Platform Loader and Manager (PLM)\", \"versions\": [{\"status\": \"affected\", \"version\": \"Refer to AMD-SB-8011\", \"versionType\": \"custom\"}], \"defaultStatus\": \"affected\"}], \"datePublic\": \"2025-06-03T16:00:00.000Z\", \"references\": [{\"url\": \"https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8011.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"In AMD Versal Adaptive SoC devices, the incorrect configuration of the SSS during runtime (post-boot) cryptographic operations could cause data to be incorrectly written to and read from invalid locations as well as returning incorrect cryptographic data.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-682\", \"description\": \"CWE-682 Incorrect Calculation\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-772\", \"description\": \"CWE-772 Missing Release of Resource after Effective Lifetime\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-940\", \"description\": \"CWE-940 Improper Verification of Source of a Communication Channel\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-941\", \"description\": \"CWE-941 Incorrectly Specified Destination in a Communication Channel\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-497\", \"description\": \"CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere\"}]}], \"providerMetadata\": {\"orgId\": \"b58fc414-a1e4-4f92-9d70-1add41838648\", \"shortName\": \"AMD\", \"dateUpdated\": \"2025-06-09T23:57:39.748Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-0036\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-10T15:27:43.315Z\", \"dateReserved\": \"2024-11-21T16:18:02.918Z\", \"assignerOrgId\": \"b58fc414-a1e4-4f92-9d70-1add41838648\", \"datePublished\": \"2025-06-09T23:57:39.748Z\", \"assignerShortName\": \"AMD\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…