CVE-2025-5444 (GCVE-0-2025-5444)
Vulnerability from cvelistv5 – Published: 2025-06-02 12:00 – Updated: 2025-06-02 16:28
VLAI?
Title
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection
Summary
A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
6.3 (Medium)
6.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Linksys | RE6500 |
Affected:
1.0.013.001
Affected: 1.0.04.001 Affected: 1.0.04.002 Affected: 1.1.05.003 Affected: 1.2.07.001 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
pjqwudi (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5444",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-02T16:27:49.243918Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-02T16:28:16.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RE6500",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE6250",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE6300",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE6350",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE7000",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE9000",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "pjqwudi (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion RP_UpgradeFWByBBS der Datei /goform/RP_UpgradeFWByBBS. Dank der Manipulation des Arguments type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-02T12:00:17.752Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-310783 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.310783"
},
{
"name": "VDB-310783 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.310783"
},
{
"name": "Submit #584366 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.584366"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md"
},
{
"tags": [
"product"
],
"url": "https://www.linksys.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-01T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-01T19:11:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5444",
"datePublished": "2025-06-02T12:00:17.752Z",
"dateReserved": "2025-06-01T17:06:30.726Z",
"dateUpdated": "2025-06-02T16:28:16.426Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-5444\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-06-02T12:15:26.337\",\"lastModified\":\"2025-06-10T15:14:50.777\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado una vulnerabilidad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 (1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001), clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n RP_UpgradeFWByBBS del archivo /goform/RP_UpgradeFWByBBS. La manipulaci\u00f3n del argumento type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw provoca la inyecci\u00f3n de comandos del sistema operativo. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"},{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11F24125-412F-473A-BF34-02284F8DAC2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7424D2C2-BCF4-4B2D-BE59-71B50B13FE77\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70728D67-153A-49FA-80E2-0DE9086DA253\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"898FD49F-4225-47FF-822C-9E4FFB5EE192\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E3A6A93-D598-4F52-808C-EAA45B468066\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"25647318-6422-418C-99B8-C806FF490028\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FFD3F65-E520-415D-BAB8-57FACEA5BEC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DC2325A-068F-4B5E-A365-6BF1103E320E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D04E83B6-EE99-42EB-AA37-895B1467CEDA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"92354C9C-D1B2-4143-803D-DE5EF7842184\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52622B22-2E42-443B-81DA-7C42ECCF0564\"}]}]}],\"references\":[{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.310783\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://vuldb.com/?id.310783\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.584366\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.linksys.com/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-06-02T12:00:17.752Z\"}, \"title\": \"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection\", \"problemTypes\": [{\"descriptions\": [{\"type\": \"CWE\", \"cweId\": \"CWE-78\", \"lang\": \"en\", \"description\": \"OS Command Injection\"}]}, {\"descriptions\": [{\"type\": \"CWE\", \"cweId\": \"CWE-77\", \"lang\": \"en\", \"description\": \"Command Injection\"}]}], \"affected\": [{\"vendor\": \"Linksys\", \"product\": \"RE6500\", \"versions\": [{\"version\": \"1.0.013.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.002\", \"status\": \"affected\"}, {\"version\": \"1.1.05.003\", \"status\": \"affected\"}, {\"version\": \"1.2.07.001\", \"status\": \"affected\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6250\", \"versions\": [{\"version\": \"1.0.013.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.002\", \"status\": \"affected\"}, {\"version\": \"1.1.05.003\", \"status\": \"affected\"}, {\"version\": \"1.2.07.001\", \"status\": \"affected\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6300\", \"versions\": [{\"version\": \"1.0.013.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.002\", \"status\": \"affected\"}, {\"version\": \"1.1.05.003\", \"status\": \"affected\"}, {\"version\": \"1.2.07.001\", \"status\": \"affected\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6350\", \"versions\": [{\"version\": \"1.0.013.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.002\", \"status\": \"affected\"}, {\"version\": \"1.1.05.003\", \"status\": \"affected\"}, {\"version\": \"1.2.07.001\", \"status\": \"affected\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE7000\", \"versions\": [{\"version\": \"1.0.013.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.002\", \"status\": \"affected\"}, {\"version\": \"1.1.05.003\", \"status\": \"affected\"}, {\"version\": \"1.2.07.001\", \"status\": \"affected\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE9000\", \"versions\": [{\"version\": \"1.0.013.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.001\", \"status\": \"affected\"}, {\"version\": \"1.0.04.002\", \"status\": \"affected\"}, {\"version\": \"1.1.05.003\", \"status\": \"affected\"}, {\"version\": \"1.2.07.001\", \"status\": \"affected\"}]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"In Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion RP_UpgradeFWByBBS der Datei /goform/RP_UpgradeFWByBBS. Dank der Manipulation des Arguments type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\", \"baseSeverity\": \"MEDIUM\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"baseSeverity\": \"MEDIUM\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"baseSeverity\": \"MEDIUM\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\"}}], \"timeline\": [{\"time\": \"2025-06-01T00:00:00.000Z\", \"lang\": \"en\", \"value\": \"Advisory disclosed\"}, {\"time\": \"2025-06-01T02:00:00.000Z\", \"lang\": \"en\", \"value\": \"VulDB entry created\"}, {\"time\": \"2025-06-01T19:11:52.000Z\", \"lang\": \"en\", \"value\": \"VulDB entry last update\"}], \"credits\": [{\"lang\": \"en\", \"value\": \"pjqwudi (VulDB User)\", \"type\": \"reporter\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.310783\", \"name\": \"VDB-310783 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.310783\", \"name\": \"VDB-310783 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.584366\", \"name\": \"Submit #584366 | Linksys RE6500\\u3001RE6250\\u3001RE6300\\u3001RE6350\\u3001RE7000\\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.linksys.com/\", \"tags\": [\"product\"]}]}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5444\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-02T16:27:49.243918Z\"}}}], \"references\": [{\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-02T16:27:58.594Z\"}}]}",
"cveMetadata": "{\"cveId\": \"CVE-2025-5444\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"VulDB\", \"dateReserved\": \"2025-06-01T17:06:30.726Z\", \"datePublished\": \"2025-06-02T12:00:17.752Z\", \"dateUpdated\": \"2025-06-02T16:28:16.426Z\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…