Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2025-7746 (GCVE-0-2025-7746)
Vulnerability from cvelistv5 – Published: 2025-09-09 21:02 – Updated: 2025-11-03 18:14- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives |
Affected:
all versions
|
|
| Schneider Electric | ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives |
Affected:
all versions
|
|
| Schneider Electric | ILC992 InterLink Converter |
Affected:
all versions
|
|
| Schneider Electric | ATV340E Altivar Machine Drives |
Affected:
all versions
|
|
| Schneider Electric | ATV6000 Medium Voltage Altivar Process Drives |
Affected:
all versions
|
|
| Schneider Electric | ATS490 Altivar Soft Starter |
Affected:
all versions
|
|
| Schneider Electric | VW3A3720 & VW3A3721 Altivar Process Communication Modules |
Affected:
all versions
|
|
| Schneider Electric | VW3A3530D: ATVdPAC module |
Affected:
all versions , < v25.0
(version)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-10T13:40:20.821038Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T16:10:34.376Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T18:14:06.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Sep/69"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC992 InterLink Converter",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV340E Altivar Machine Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV6000 Medium Voltage Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATS490 Altivar Soft Starter",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VW3A3530D: ATVdPAC module",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v25.0",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"datePublic": "2025-09-09T04:01:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
}
],
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T21:02:08.936Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-7746",
"datePublished": "2025-09-09T21:02:08.936Z",
"dateReserved": "2025-07-17T09:10:51.541Z",
"dateUpdated": "2025-11-03T18:14:06.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-7746",
"date": "2026-05-30",
"epss": "0.0008",
"percentile": "0.23583"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-7746\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-09-09T21:15:39.353\",\"lastModified\":\"2025-11-03T19:16:15.943\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"LOW\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"http://seclists.org/fulldisclosure/2025/Sep/69\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-7746\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-10T13:40:20.821038Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-10T16:10:19.075Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"LOW\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ILC992 InterLink Converter\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATV340E Altivar Machine Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATV6000 Medium Voltage Altivar Process Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATS490 Altivar Soft Starter\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"VW3A3530D: ATVdPAC module\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\", \"lessThan\": \"v25.0\", \"versionType\": \"version\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-09-09T04:01:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\\u2019s browser.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\\u2019s browser.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-09-09T21:02:08.936Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-7746\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-10T16:10:34.376Z\", \"dateReserved\": \"2025-07-17T09:10:51.541Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-09-09T21:02:08.936Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"CVSS 4.0": "AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N",
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (Schneider Electric ATV630), - (Schneider Electric ATV650), - (Schneider Electric ATV660), - (Schneider Electric ATV680), - (Schneider Electric ATV6A0), - (Schneider Electric ATV6B0), - (Schneider Electric ATV6L0), - (Schneider Electric ATV930), - (Schneider Electric ATV950), - (Schneider Electric ATV955), - (Schneider Electric ATV960), - (Schneider Electric ATV980), - (Schneider Electric ATV9A0), - (Schneider Electric ATV9B0), - (Schneider Electric ATV9L0), - (Schneider Electric ATV991), - (Schneider Electric ATV992), - (Schneider Electric ATV993), - (Schneider Electric ILC992 InterLink Converter), - (Schneider Electric ATV340E Altivar Machine Drives), - (Schneider Electric ATV6000 Medium Voltage Altivar Process Drives), - (Schneider Electric ATS490 Altivar Soft Starter), - (Schneider Electric VW3A3720 Altivar Process Communication Modules), - (Schneider Electric VW3A3721 Altivar Process Communication Modules), \u0434\u043e 25.0 (Schneider Electric VW3A3530D: ATVdPAC module)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "09.09.2025",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "17.12.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "17.12.2025",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2025-16043",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2025-7746",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Schneider Electric ATV630, Schneider Electric ATV650, Schneider Electric ATV660, Schneider Electric ATV680, Schneider Electric ATV6A0, Schneider Electric ATV6B0, Schneider Electric ATV6L0, Schneider Electric ATV930, Schneider Electric ATV950, Schneider Electric ATV955, Schneider Electric ATV960, Schneider Electric ATV980, Schneider Electric ATV9A0, Schneider Electric ATV9B0, Schneider Electric ATV9L0, Schneider Electric ATV991, Schneider Electric ATV992, Schneider Electric ATV993, Schneider Electric ILC992 InterLink Converter, Schneider Electric ATV340E Altivar Machine Drives, Schneider Electric ATV6000 Medium Voltage Altivar Process Drives, Schneider Electric ATS490 Altivar Soft Starter, Schneider Electric VW3A3720 Altivar Process Communication Modules, Schneider Electric VW3A3721 Altivar Process Communication Modules, Schneider Electric VW3A3530D: ATVdPAC module",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0445 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432 Schneider Electric ATV, ILC, VW Series, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435\u043c \u043c\u0435\u0440 \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b \u0432\u0435\u0431-\u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u043c\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435 \u043c\u0435\u0440 \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b \u0432\u0435\u0431-\u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b (\u0438\u043b\u0438 \\\u00ab\u041c\u0435\u0436\u0441\u0430\u0439\u0442\u043e\u0432\u0430\u044f \u0441\u0446\u0435\u043d\u0430\u0440\u043d\u0430\u044f \u0430\u0442\u0430\u043a\u0430\\\u00bb) (CWE-79)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0445 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432 Schneider Electric ATV, ILC, VW Series \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435\u043c \u043c\u0435\u0440 \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b \u0432\u0435\u0431-\u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e, \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u043c\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u0418\u043d\u044a\u0435\u043a\u0446\u0438\u044f",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-79",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,4)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.1 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,1)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u043e\u0446\u0435\u043d\u043a\u0430 CVSS 4.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5,3)"
}
FKIE_CVE-2025-7746
Vulnerability from fkie_nvd - Published: 2025-09-09 21:15 - Updated: 2026-04-15 00:35| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
}
],
"id": "CVE-2025-7746",
"lastModified": "2026-04-15T00:35:42.020",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2025-09-09T21:15:39.353",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://seclists.org/fulldisclosure/2025/Sep/69"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-V42J-XH9R-GFMM
Vulnerability from github – Published: 2025-09-09 21:30 – Updated: 2025-11-03 21:34CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
{
"affected": [],
"aliases": [
"CVE-2025-7746"
],
"database_specific": {
"cwe_ids": [
"CWE-79"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-09-09T21:15:39Z",
"severity": "MODERATE"
},
"details": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser.",
"id": "GHSA-v42j-xh9r-gfmm",
"modified": "2025-11-03T21:34:27Z",
"published": "2025-09-09T21:30:31Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-7746"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
},
{
"type": "WEB",
"url": "http://seclists.org/fulldisclosure/2025/Sep/69"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-25-259-01
Vulnerability from csaf_cisa - Published: 2025-09-09 04:00 - Updated: 2026-05-26 06:00CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ATVdPAC module Version 25.0
Schneider Electric / ATVdPAC module
|
VW3A3530D
|
25.0 | |
|
ATV630 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV630
|
4.5 | ||
|
ATV650 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV650
|
4.5 | ||
|
ATV660 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV660
|
4.5 | ||
|
ATV680 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV680
|
4.5 | ||
|
ATV6A0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV6A0
|
4.5 | ||
|
ATV6B0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV6B0
|
4.5 | ||
|
ATV6L0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV6L0
|
4.5 | ||
|
ATV930 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV930
|
4.5 | ||
|
ATV950 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV950
|
4.5 | ||
|
ATV955 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV955
|
4.5 | ||
|
ATV960 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV960
|
4.5 | ||
|
ATV980 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV980
|
4.5 | ||
|
ATV9A0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV9A0
|
4.5 | ||
|
ATV9B0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV9B0
|
4.5 | ||
|
ATV9L0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV9L0
|
4.5 | ||
|
ATV991 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV991
|
4.5 | ||
|
ATV992 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV992
|
4.5 | ||
|
ATV993 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV993
|
4.5 | ||
|
ATV340 Altivar Machine Drives Version 4.5
Schneider Electric / Altivar Machine Drives / ATV340
|
4.5 | ||
|
Altivar Soft Starter ATS490 Version 1.2ie05
Schneider Electric / Altivar Soft Starter / ATS490
|
1.2ie05 | ||
|
ATV6000 Medium Voltage Altivar Process Drives Version 2.2
Schneider Electric / Altivar Process Drives / ATV6000 Medium Voltage
|
2.2 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ATVdPAC module Versions prior to 25.0
Schneider Electric / ATVdPAC module
|
VW3A3530D
|
vers:intdot/<25.0 |
Vendor Fix
Mitigation
|
|
ATV630 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV630
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV650 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV650
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV660 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV660
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV680 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV680
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6A0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV6A0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6B0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV6B0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6L0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV6L0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV930 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV930
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV950 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV950
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV955 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV955
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV960 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV960
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV980 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV980
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV9A0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV9A0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV9B0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV9B0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV9L0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV9L0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV991 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV991
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV992 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV992
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV993 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV993
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ILC992 InterLink Converter All Versions
Schneider Electric / ILC992 InterLink Converter
|
vers:all/* |
Mitigation
|
|
|
ATV340E Altivar Machine Drives Versions prior to 4.5
Schneider Electric / Altivar Machine Drives / ATV340E
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6000 Medium Voltage Altivar Process Drives Versions prior to 2.2
Schneider Electric / Altivar Process Drives / ATV6000 Medium Voltage
|
vers:intdot/<2.2 |
Mitigation
Vendor Fix
|
|
|
Altivar Soft Starter ATS490 Versions prior to v1.2ie05
Schneider Electric / Altivar Soft Starter / ATS490
|
vers:generic/<1.2ie05 |
Vendor Fix
fix
Mitigation
|
|
|
Altivar Process Communication Modules All Versions
Schneider Electric / Altivar Process Communication Modules
|
VW3A3720
|
vers:all/* |
Mitigation
|
|
Altivar Process Communication Modules All Versions
Schneider Electric / Altivar Process Communication Modules
|
VW3A3721
|
vers:all/* |
Mitigation
|
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric CPCERT",
"summary": "reported this vulnerability to CISA."
},
{
"names": [
"Thomas Weber",
"David Blagojevic"
],
"organization": "CyberDanube",
"summary": "reported this vulnerability to Schneider Electric."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its [ATVdPAC module](http://www.se.com/ww/en/product/VW3A3530D/atv-dpac-module/) / [ATV6000 Medium Voltage Altivar Process Drives](http://www.se.com/ww/en/product-range/65607-altivar-process-atv6000) / [ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives](http://www.se.com/ww/en/product-range/62317-altivar-process-atv600) / [ATV930/950/955/960/980/9A0/9B0/9L0 Altivar Process Drives](http://www.se.com/ww/en/product-range/63124-altivar-process-atv900) / [ATV340E Altivar Machine Drives](http://www.se.com/ww/en/product-range/63441-altivar-machine-atv340#products) /[ATS490 Altivar Soft Starter](http://www.se.com/ww/en/product-range/213421154-altivar-soft-starter-ats490) / [Altivar Process Communication Modules](http://www.se.com/ww/en/product-range/62317-altivar-process-atv600/117623851529-modular-drives-apm) product(s). \n\nFailure to apply remediation mitigations provided below may risk Cross-Site Scripting, which could result in partial loss of confidentiality and integrity of the workstation running a Web browser.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u0027s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-252-01 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "Multiple Altivar Process Drives and Communication Modules - SEVD-2025-252-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-252-01.json"
},
{
"category": "self",
"summary": "Multiple Altivar Process Drives and Communication Modules - SEVD-2025-252-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/ww/en/download/document/7EN52-0390/"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-259-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-259-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-259-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Schneider Electric Altivar Products, ATVdPAC Module, ILC992 InterLink Converter (Update B)",
"tracking": {
"current_release_date": "2026-05-26T06:00:00.000000Z",
"generator": {
"date": "2026-05-26T13:10:34.070561Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-25-259-01",
"initial_release_date": "2025-09-09T04:00:00.000000Z",
"revision_history": [
{
"date": "2025-09-09T04:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Original Release"
},
{
"date": "2025-09-16T04:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "Fixed the typo on the product name Altivar Process Communication Modules."
},
{
"date": "2025-10-14T07:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "Remediations are now available for ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives, ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives and ATV340E Altivar Machine Drives."
},
{
"date": "2025-12-09T08:00:00.000000Z",
"legacy_version": "Additional Release 3",
"number": "4",
"summary": "Remediations are now available for ATS490 Altivar Soft Starter."
},
{
"date": "2026-05-12T07:00:00.000000Z",
"legacy_version": "Additional Release 4",
"number": "5",
"summary": "Remediations are now available for ATV6000 Altivar Process Drives."
},
{
"date": "2026-05-26T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "6",
"summary": "CISA Republication update based on Schneider Electric CPCERT SEVD-2025-252-01 advisory"
}
],
"status": "final",
"version": "6"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c25.0",
"product": {
"name": "ATVdPAC module Versions prior to 25.0",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"VW3A3530D"
]
}
}
},
{
"category": "product_version",
"name": "25.0",
"product": {
"name": "ATVdPAC module Version 25.0",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"VW3A3530D"
]
}
}
}
],
"category": "product_name",
"name": "ATVdPAC module"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV630 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV630 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "ATV630"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV650 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0005"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV650 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "ATV650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV660 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0007"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV660 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "ATV660"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV680 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0009"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV680 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "ATV680"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV6A0 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0011"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV6A0 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "ATV6A0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV6B0 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0013"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV6B0 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0014"
}
}
],
"category": "product_name",
"name": "ATV6B0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV6L0 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0015"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV6L0 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0016"
}
}
],
"category": "product_name",
"name": "ATV6L0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV930 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0017"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV930 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0018"
}
}
],
"category": "product_name",
"name": "ATV930"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV950 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0019"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV950 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0020"
}
}
],
"category": "product_name",
"name": "ATV950"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV955 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0021"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV955 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0022"
}
}
],
"category": "product_name",
"name": "ATV955"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV960 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0023"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV960 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0024"
}
}
],
"category": "product_name",
"name": "ATV960"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV980 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0025"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV980 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0026"
}
}
],
"category": "product_name",
"name": "ATV980"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV9A0 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0027"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV9A0 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0028"
}
}
],
"category": "product_name",
"name": "ATV9A0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV9B0 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0029"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV9B0 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0030"
}
}
],
"category": "product_name",
"name": "ATV9B0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV9L0 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0031"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV9L0 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0032"
}
}
],
"category": "product_name",
"name": "ATV9L0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV991 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0033"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV991 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0034"
}
}
],
"category": "product_name",
"name": "ATV991"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV992 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0035"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV992 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0036"
}
}
],
"category": "product_name",
"name": "ATV992"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV993 Altivar Process Drives Versions prior to 4.5",
"product_id": "CSAFPID-0037"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV993 Altivar Process Drives Version 4.5",
"product_id": "CSAFPID-0038"
}
}
],
"category": "product_name",
"name": "ATV993"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.2",
"product": {
"name": "ATV6000 Medium Voltage Altivar Process Drives Versions prior to 2.2",
"product_id": "CSAFPID-0039"
}
},
{
"category": "product_version",
"name": "2.2",
"product": {
"name": "ATV6000 Medium Voltage Altivar Process Drives Version 2.2",
"product_id": "CSAFPID-0040"
}
}
],
"category": "product_name",
"name": "ATV6000 Medium Voltage"
}
],
"category": "product_family",
"name": "Altivar Process Drives"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "ILC992 InterLink Converter All Versions",
"product_id": "CSAFPID-0041"
}
}
],
"category": "product_name",
"name": "ILC992 InterLink Converter"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV340E Altivar Machine Drives Versions prior to 4.5",
"product_id": "CSAFPID-0042"
}
}
],
"category": "product_name",
"name": "ATV340E"
},
{
"branches": [
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV340 Altivar Machine Drives Version 4.5",
"product_id": "CSAFPID-0043"
}
}
],
"category": "product_name",
"name": "ATV340"
}
],
"category": "product_family",
"name": "Altivar Machine Drives"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003c1.2ie05",
"product": {
"name": "Altivar Soft Starter ATS490 Versions prior to v1.2ie05",
"product_id": "CSAFPID-0044"
}
},
{
"category": "product_version",
"name": "1.2ie05",
"product": {
"name": "Altivar Soft Starter ATS490 Version 1.2ie05",
"product_id": "CSAFPID-0045"
}
}
],
"category": "product_name",
"name": "ATS490"
}
],
"category": "product_family",
"name": "Altivar Soft Starter"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Altivar Process Communication Modules All Versions",
"product_id": "CSAFPID-0046",
"product_identification_helper": {
"model_numbers": [
"VW3A3720"
]
}
}
}
],
"category": "product_name",
"name": "Altivar Process Communication Modules"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Altivar Process Communication Modules All Versions",
"product_id": "CSAFPID-0047",
"product_identification_helper": {
"model_numbers": [
"VW3A3721"
]
}
}
}
],
"category": "product_name",
"name": "Altivar Process Communication Modules"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Thomas Weber",
"David Blagojevic"
],
"organization": "CyberDanube"
}
],
"cve": "CVE-2025-7746",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability \r\nexists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read \r\ndata in a victim\u2019s browser.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 5.3 | Medium | [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N)",
"title": "CVSS v4.0 Base Score"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002",
"CSAFPID-0004",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0016",
"CSAFPID-0018",
"CSAFPID-0020",
"CSAFPID-0022",
"CSAFPID-0024",
"CSAFPID-0026",
"CSAFPID-0028",
"CSAFPID-0030",
"CSAFPID-0032",
"CSAFPID-0034",
"CSAFPID-0036",
"CSAFPID-0038",
"CSAFPID-0043",
"CSAFPID-0045",
"CSAFPID-0040"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0011",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0017",
"CSAFPID-0019",
"CSAFPID-0021",
"CSAFPID-0023",
"CSAFPID-0025",
"CSAFPID-0027",
"CSAFPID-0029",
"CSAFPID-0031",
"CSAFPID-0033",
"CSAFPID-0035",
"CSAFPID-0037",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0039",
"CSAFPID-0044",
"CSAFPID-0046",
"CSAFPID-0047"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-7746"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/79.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 25.0 of VW3A3530D: ATVdPAC module includes a \r\nfix for this vulnerability and is available upon request from \r\nSchneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp). ",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
}
},
{
"category": "vendor_fix",
"details": "The version 4.5 of ATV6xx drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/62317-altivar-process-atv600/#software-and-firmware",
"product_ids": [
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0011",
"CSAFPID-0013",
"CSAFPID-0015"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/62317-altivar-process-atv600/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "The version 4.5 of ATV9xx drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/63124-altivar-process-atv900/#software-and-firmware",
"product_ids": [
"CSAFPID-0017",
"CSAFPID-0019",
"CSAFPID-0021",
"CSAFPID-0023",
"CSAFPID-0025",
"CSAFPID-0027",
"CSAFPID-0029",
"CSAFPID-0031",
"CSAFPID-0033",
"CSAFPID-0035",
"CSAFPID-0037"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/63124-altivar-process-atv900/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "The version 4.5 of ATV340 drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/63441-altivar-machine-atv340/#software-and-firmware",
"product_ids": [
"CSAFPID-0042"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/63441-altivar-machine-atv340/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "The version 1.2ie05 of ATS490 drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/ATS490-Firmware/",
"product_ids": [
"CSAFPID-0044"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/download/document/ATS490-Firmware/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\u2022 End user cybersecurity awareness and workstation protections \u2022 Deactivate the Webserver after use when not needed. \u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 80/HTTP \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0011",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0017",
"CSAFPID-0019",
"CSAFPID-0021",
"CSAFPID-0023",
"CSAFPID-0025",
"CSAFPID-0027",
"CSAFPID-0029",
"CSAFPID-0031",
"CSAFPID-0033",
"CSAFPID-0035",
"CSAFPID-0037",
"CSAFPID-0042",
"CSAFPID-0039",
"CSAFPID-0044"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future versions of \u2022 ILC992 InterLink Converter \u2022 VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 End user cybersecurity awareness and workstation protections \u2022 Deactivate the Webserver after use when not needed. \u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 80/HTTP \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required.",
"product_ids": [
"CSAFPID-0041",
"CSAFPID-0046",
"CSAFPID-0047"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 2.2 of ATV6000 drives includes a fix for this vulnerability and is available upon request from Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp).",
"product_ids": [
"CSAFPID-0039"
],
"restart_required": {
"category": "system"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0011",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0017",
"CSAFPID-0019",
"CSAFPID-0021",
"CSAFPID-0023",
"CSAFPID-0025",
"CSAFPID-0027",
"CSAFPID-0029",
"CSAFPID-0031",
"CSAFPID-0033",
"CSAFPID-0035",
"CSAFPID-0037",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0039",
"CSAFPID-0044",
"CSAFPID-0046",
"CSAFPID-0047"
]
}
],
"title": "CVE-2025-7746"
}
]
}
SEVD-2025-252-01
Vulnerability from csaf_se - Published: 2025-09-09 04:00 - Updated: 2026-05-12 07:00CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ATVdPAC module Version 25.0
Schneider Electric / ATVdPAC module
|
VW3A3530D
|
25.0 | |
|
ATV630 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV630
|
4.5 | ||
|
ATV650 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV650
|
4.5 | ||
|
ATV660 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV660
|
4.5 | ||
|
ATV680 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV680
|
4.5 | ||
|
ATV6A0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV6A0
|
4.5 | ||
|
ATV6B0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV6B0
|
4.5 | ||
|
ATV6L0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV6L0
|
4.5 | ||
|
ATV930 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV930
|
4.5 | ||
|
ATV950 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV950
|
4.5 | ||
|
ATV955 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV955
|
4.5 | ||
|
ATV960 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV960
|
4.5 | ||
|
ATV980 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV980
|
4.5 | ||
|
ATV9A0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV9A0
|
4.5 | ||
|
ATV9B0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV9B0
|
4.5 | ||
|
ATV9L0 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV9L0
|
4.5 | ||
|
ATV991 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV991
|
4.5 | ||
|
ATV992 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV992
|
4.5 | ||
|
ATV993 Altivar Process Drives Version 4.5
Schneider Electric / Altivar Process Drives / ATV993
|
4.5 | ||
|
ATV340 Altivar Machine Drives Version 4.5
Schneider Electric / Altivar Machine Drives / ATV340
|
4.5 | ||
|
Altivar Soft Starter ATS490 Version 1.2ie05
Schneider Electric / Altivar Soft Starter / ATS490
|
1.2ie05 | ||
|
ATV6000 Medium Voltage Altivar Process Drives Version 2.2
Schneider Electric / Altivar Process Drives / ATV6000 Medium Voltage
|
2.2 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ATVdPAC module Versions prior to 25.0
Schneider Electric / ATVdPAC module
|
VW3A3530D
|
vers:intdot/<25.0 |
Vendor Fix
Mitigation
|
|
ATV630 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV630
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV650 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV650
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV660 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV660
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV680 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV680
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6A0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV6A0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6B0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV6B0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6L0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV6L0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV930 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV930
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV950 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV950
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV955 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV955
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV960 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV960
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV980 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV980
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV9A0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV9A0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV9B0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV9B0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV9L0 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV9L0
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV991 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV991
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV992 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV992
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV993 Altivar Process Drives Versions prior to 4.5
Schneider Electric / Altivar Process Drives / ATV993
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ILC992 InterLink Converter All Versions
Schneider Electric / ILC992 InterLink Converter
|
vers:all/* |
Mitigation
|
|
|
ATV340E Altivar Machine Drives Versions prior to 4.5
Schneider Electric / Altivar Machine Drives / ATV340E
|
vers:intdot/<4.5 |
Vendor Fix
fix
Mitigation
|
|
|
ATV6000 Medium Voltage Altivar Process Drives Versions prior to 2.2
Schneider Electric / Altivar Process Drives / ATV6000 Medium Voltage
|
vers:intdot/<2.2 |
Mitigation
Vendor Fix
|
|
|
Altivar Soft Starter ATS490 Versions prior to v1.2ie05
Schneider Electric / Altivar Soft Starter / ATS490
|
vers:generic/<1.2ie05 |
Vendor Fix
fix
Mitigation
|
|
|
Altivar Process Communication Modules All Versions
Schneider Electric / Altivar Process Communication Modules
|
VW3A3720
|
vers:all/* |
Mitigation
|
|
Altivar Process Communication Modules All Versions
Schneider Electric / Altivar Process Communication Modules
|
VW3A3721
|
vers:all/* |
Mitigation
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its [ATVdPAC module](http://www.se.com/ww/en/product/VW3A3530D/atv-dpac-module/) / [ATV6000 Medium Voltage Altivar Process Drives](http://www.se.com/ww/en/product-range/65607-altivar-process-atv6000) / [ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives](http://www.se.com/ww/en/product-range/62317-altivar-process-atv600) / [ATV930/950/955/960/980/9A0/9B0/9L0 Altivar Process Drives](http://www.se.com/ww/en/product-range/63124-altivar-process-atv900) / [ATV340E Altivar Machine Drives](http://www.se.com/ww/en/product-range/63441-altivar-machine-atv340#products) /[ATS490 Altivar Soft Starter](http://www.se.com/ww/en/product-range/213421154-altivar-soft-starter-ats490) / [Altivar Process Communication Modules](http://www.se.com/ww/en/product-range/62317-altivar-process-atv600/117623851529-modular-drives-apm) product(s). \n\nFailure to apply remediation mitigations provided below may risk Cross-Site Scripting, which could result in partial loss of confidentiality and integrity of the workstation running a Web browser.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u0027s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Multiple Altivar Process Drives and Communication Modules - SEVD-2025-252-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
},
{
"category": "self",
"summary": "Multiple Altivar Process Drives and Communication Modules - SEVD-2025-252-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-252-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/ww/en/download/document/7EN52-0390/"
}
],
"title": "Multiple Altivar Process Drives and Communication Modules",
"tracking": {
"current_release_date": "2026-05-12T07:00:00.000Z",
"generator": {
"date": "2026-04-29T04:04:37.085Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2025-252-01",
"initial_release_date": "2025-09-09T04:00:00.000Z",
"revision_history": [
{
"date": "2025-09-09T04:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-09-16T04:00:00.000Z",
"number": "1.0.1",
"summary": "Fixed the typo on the product name Altivar Process Communication Modules."
},
{
"date": "2025-10-14T07:00:00.000Z",
"number": "2.0.0",
"summary": "Remediations are now available for ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives, ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives and ATV340E Altivar Machine Drives."
},
{
"date": "2025-12-09T08:00:00.000Z",
"number": "3.0.0",
"summary": "Remediations are now available for ATS490 Altivar Soft Starter."
},
{
"date": "2026-05-12T07:00:00.000Z",
"number": "4.0.0",
"summary": "Remediations are now available for ATV6000 Altivar Process Drives."
}
],
"status": "final",
"version": "4.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c25.0",
"product": {
"name": "ATVdPAC module Versions prior to 25.0",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"VW3A3530D"
]
}
}
},
{
"category": "product_version",
"name": "25.0",
"product": {
"name": "ATVdPAC module Version 25.0",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"VW3A3530D"
]
}
}
}
],
"category": "product_name",
"name": "ATVdPAC module"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV630 Altivar Process Drives Versions prior to 4.5",
"product_id": "3"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV630 Altivar Process Drives Version 4.5",
"product_id": "27"
}
}
],
"category": "product_name",
"name": "ATV630"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV650 Altivar Process Drives Versions prior to 4.5",
"product_id": "4"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV650 Altivar Process Drives Version 4.5",
"product_id": "28"
}
}
],
"category": "product_name",
"name": "ATV650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV660 Altivar Process Drives Versions prior to 4.5",
"product_id": "5"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV660 Altivar Process Drives Version 4.5",
"product_id": "29"
}
}
],
"category": "product_name",
"name": "ATV660"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV680 Altivar Process Drives Versions prior to 4.5",
"product_id": "6"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV680 Altivar Process Drives Version 4.5",
"product_id": "30"
}
}
],
"category": "product_name",
"name": "ATV680"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV6A0 Altivar Process Drives Versions prior to 4.5",
"product_id": "7"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV6A0 Altivar Process Drives Version 4.5",
"product_id": "31"
}
}
],
"category": "product_name",
"name": "ATV6A0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV6B0 Altivar Process Drives Versions prior to 4.5",
"product_id": "8"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV6B0 Altivar Process Drives Version 4.5",
"product_id": "32"
}
}
],
"category": "product_name",
"name": "ATV6B0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV6L0 Altivar Process Drives Versions prior to 4.5",
"product_id": "9"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV6L0 Altivar Process Drives Version 4.5",
"product_id": "33"
}
}
],
"category": "product_name",
"name": "ATV6L0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV930 Altivar Process Drives Versions prior to 4.5",
"product_id": "10"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV930 Altivar Process Drives Version 4.5",
"product_id": "34"
}
}
],
"category": "product_name",
"name": "ATV930"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV950 Altivar Process Drives Versions prior to 4.5",
"product_id": "11"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV950 Altivar Process Drives Version 4.5",
"product_id": "35"
}
}
],
"category": "product_name",
"name": "ATV950"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV955 Altivar Process Drives Versions prior to 4.5",
"product_id": "12"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV955 Altivar Process Drives Version 4.5",
"product_id": "36"
}
}
],
"category": "product_name",
"name": "ATV955"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV960 Altivar Process Drives Versions prior to 4.5",
"product_id": "13"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV960 Altivar Process Drives Version 4.5",
"product_id": "37"
}
}
],
"category": "product_name",
"name": "ATV960"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV980 Altivar Process Drives Versions prior to 4.5",
"product_id": "14"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV980 Altivar Process Drives Version 4.5",
"product_id": "38"
}
}
],
"category": "product_name",
"name": "ATV980"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV9A0 Altivar Process Drives Versions prior to 4.5",
"product_id": "15"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV9A0 Altivar Process Drives Version 4.5",
"product_id": "39"
}
}
],
"category": "product_name",
"name": "ATV9A0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV9B0 Altivar Process Drives Versions prior to 4.5",
"product_id": "16"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV9B0 Altivar Process Drives Version 4.5",
"product_id": "40"
}
}
],
"category": "product_name",
"name": "ATV9B0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV9L0 Altivar Process Drives Versions prior to 4.5",
"product_id": "17"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV9L0 Altivar Process Drives Version 4.5",
"product_id": "41"
}
}
],
"category": "product_name",
"name": "ATV9L0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV991 Altivar Process Drives Versions prior to 4.5",
"product_id": "18"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV991 Altivar Process Drives Version 4.5",
"product_id": "42"
}
}
],
"category": "product_name",
"name": "ATV991"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV992 Altivar Process Drives Versions prior to 4.5",
"product_id": "19"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV992 Altivar Process Drives Version 4.5",
"product_id": "43"
}
}
],
"category": "product_name",
"name": "ATV992"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV993 Altivar Process Drives Versions prior to 4.5",
"product_id": "20"
}
},
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV993 Altivar Process Drives Version 4.5",
"product_id": "44"
}
}
],
"category": "product_name",
"name": "ATV993"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.2",
"product": {
"name": "ATV6000 Medium Voltage Altivar Process Drives Versions prior to 2.2",
"product_id": "23"
}
},
{
"category": "product_version",
"name": "2.2",
"product": {
"name": "ATV6000 Medium Voltage Altivar Process Drives Version 2.2",
"product_id": "47"
}
}
],
"category": "product_name",
"name": "ATV6000 Medium Voltage"
}
],
"category": "product_family",
"name": "Altivar Process Drives"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "ILC992 InterLink Converter All Versions",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "ILC992 InterLink Converter"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.5",
"product": {
"name": "ATV340E Altivar Machine Drives Versions prior to 4.5",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "ATV340E"
},
{
"branches": [
{
"category": "product_version",
"name": "4.5",
"product": {
"name": "ATV340 Altivar Machine Drives Version 4.5",
"product_id": "45"
}
}
],
"category": "product_name",
"name": "ATV340"
}
],
"category": "product_family",
"name": "Altivar Machine Drives"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003c1.2ie05",
"product": {
"name": "Altivar Soft Starter ATS490 Versions prior to v1.2ie05",
"product_id": "24"
}
},
{
"category": "product_version",
"name": "1.2ie05",
"product": {
"name": "Altivar Soft Starter ATS490 Version 1.2ie05",
"product_id": "46"
}
}
],
"category": "product_name",
"name": "ATS490"
}
],
"category": "product_family",
"name": "Altivar Soft Starter"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Altivar Process Communication Modules All Versions",
"product_id": "25",
"product_identification_helper": {
"model_numbers": [
"VW3A3720"
]
}
}
}
],
"category": "product_name",
"name": "Altivar Process Communication Modules"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Altivar Process Communication Modules All Versions",
"product_id": "26",
"product_identification_helper": {
"model_numbers": [
"VW3A3721"
]
}
}
}
],
"category": "product_name",
"name": "Altivar Process Communication Modules"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Thomas Weber",
"David Blagojevic"
],
"organization": "CyberDanube"
}
],
"cve": "CVE-2025-7746",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability \r\nexists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read \r\ndata in a victim\u2019s browser.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 5.3 | Medium | [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N)",
"title": "CVSS v4.0 Base Score"
}
],
"product_status": {
"fixed": [
"2",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47"
],
"known_affected": [
"1",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 25.0 of VW3A3530D: ATVdPAC module includes a \r\nfix for this vulnerability and is available upon request from \r\nSchneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp). ",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
}
},
{
"category": "vendor_fix",
"details": "The version 4.5 of ATV6xx drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/62317-altivar-process-atv600/#software-and-firmware",
"product_ids": [
"3",
"4",
"5",
"6",
"7",
"8",
"9"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/62317-altivar-process-atv600/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "The version 4.5 of ATV9xx drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/63124-altivar-process-atv900/#software-and-firmware",
"product_ids": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/63124-altivar-process-atv900/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "The version 4.5 of ATV340 drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/63441-altivar-machine-atv340/#software-and-firmware",
"product_ids": [
"22"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/63441-altivar-machine-atv340/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "The version 1.2ie05 of ATS490 drives includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/ATS490-Firmware/",
"product_ids": [
"24"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/download/document/ATS490-Firmware/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\u2022 End user cybersecurity awareness and workstation protections \u2022 Deactivate the Webserver after use when not needed. \u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 80/HTTP \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required.",
"product_ids": [
"1",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"22",
"23",
"24"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future versions of \u2022 ILC992 InterLink Converter \u2022 VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 End user cybersecurity awareness and workstation protections \u2022 Deactivate the Webserver after use when not needed. \u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 80/HTTP \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required.",
"product_ids": [
"21",
"25",
"26"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 2.2 of ATV6000 drives includes a fix for this vulnerability and is available upon request from Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp).",
"product_ids": [
"23"
],
"restart_required": {
"category": "system"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"1",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26"
]
}
],
"title": "CVE-2025-7746"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.