CVE-2025-9023 (GCVE-0-2025-9023)

Vulnerability from cvelistv5 – Published: 2025-08-15 08:32 – Updated: 2025-08-15 16:01
VLAI?
Summary
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.05.19
Affected: 15.03.06.44
Create a notification for this product.
    Tenda AC18 Affected: 15.03.05.19
Affected: 15.03.06.44
Create a notification for this product.
Credits
zezhifu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9023",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-15T15:59:19.714899Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-15T16:01:28.497Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            },
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        },
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            },
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zezhifu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Dabei betrifft es die Funktion formSetSchedLed der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments Time mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-15T08:32:07.431Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-320088 | Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.320088"
        },
        {
          "name": "VDB-320088 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.320088"
        },
        {
          "name": "Submit #629692 | Tenda AC7 V15.03.06.44 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.629692"
        },
        {
          "name": "Submit #629696 | Tenda AC18 V15.03.05.19(6318) Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.629696"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/zezhifu1/cve_report/blob/main/AC7/formsetschedled.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/zezhifu1/cve_report/blob/main/AC18/formsetschedled.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-14T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-14T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-14T09:13:33.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9023",
    "datePublished": "2025-08-15T08:32:07.431Z",
    "dateReserved": "2025-08-14T07:07:03.862Z",
    "dateUpdated": "2025-08-15T16:01:28.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-9023\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-08-15T09:15:31.730\",\"lastModified\":\"2025-10-03T15:03:22.527\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.\"},{\"lang\":\"es\",\"value\":\"Se ha encontrado una vulnerabilidad en Tenda AC7 y AC18 15.03.05.19/15.03.06.44. La funci\u00f3n formSetSchedLed del archivo /goform/SetLEDCfg est\u00e1 afectada. La manipulaci\u00f3n del argumento Time provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"},{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D94B37C-491D-4E7C-8273-F46FEDA62C9F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A3BEE979-5BF3-48ED-AF42-0546D4F896E9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA3A313A-5085-4ABB-92D0-A26208EE44FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF9F8AF9-F921-4348-922B-EE5E6037E7AC\"}]}]}],\"references\":[{\"url\":\"https://github.com/zezhifu1/cve_report/blob/main/AC18/formsetschedled.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/zezhifu1/cve_report/blob/main/AC7/formsetschedled.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.320088\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.320088\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.629692\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.629696\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.tenda.com.cn/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9023\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-15T15:59:19.714899Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-15T16:01:21.147Z\"}}], \"cna\": {\"title\": \"Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"zezhifu (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"AC7\", \"versions\": [{\"status\": \"affected\", \"version\": \"15.03.05.19\"}, {\"status\": \"affected\", \"version\": \"15.03.06.44\"}]}, {\"vendor\": \"Tenda\", \"product\": \"AC18\", \"versions\": [{\"status\": \"affected\", \"version\": \"15.03.05.19\"}, {\"status\": \"affected\", \"version\": \"15.03.06.44\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-08-14T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-08-14T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-08-14T09:13:33.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.320088\", \"name\": \"VDB-320088 | Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.320088\", \"name\": \"VDB-320088 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.629692\", \"name\": \"Submit #629692 | Tenda AC7 V15.03.06.44 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://vuldb.com/?submit.629696\", \"name\": \"Submit #629696 | Tenda AC18 V15.03.05.19(6318) Buffer Overflow (Duplicate)\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/zezhifu1/cve_report/blob/main/AC7/formsetschedled.md\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/zezhifu1/cve_report/blob/main/AC18/formsetschedled.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.tenda.com.cn/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.\"}, {\"lang\": \"de\", \"value\": \"Dabei betrifft es die Funktion formSetSchedLed der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments Time mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-08-15T08:32:07.431Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-9023\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-15T16:01:28.497Z\", \"dateReserved\": \"2025-08-14T07:07:03.862Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-08-15T08:32:07.431Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…