GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2017-7898

Vulnerability from fkie_nvd - Published: 2017-06-30 03:29 - Updated: 2026-06-17 01:25
Summary
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"
            }
          ]
        }
      ],
      "source": "ics-cert@hq.dhs.gov"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E44D0CCE-EDA7-4DF2-B67B-C59DFAE7F888",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E4AB51-E136-4AA3-AFF9-50F240489856",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6006CE1E-08EC-4AFC-8F35-73B24AA7F08D",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F52398D3-996E-4291-887F-6B8E0AF24AFF",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61603F24-7505-4A9E-BA9E-57C7B5A60A6E",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9558148B-3000-4D83-9AB0-380D7FBB0C9A",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C805AFD6-481C-4A32-9CE8-281F9B793263",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC9E1F42-4F17-4EA4-8D0F-30220F560A0E",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA98842B-9D09-4C37-AB34-4E9FA566BAD8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C8E3AF6-1017-4A18-99CA-854F1022ED66",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A093AA8B-7DB9-4373-AE8F-F8B879A4BE5E",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "25DA9309-964B-4C1C-8B95-9C1CD80DDC74",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D51D3F6-ABB3-4FFD-81D5-B3D3C29F0A46",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC05C3A1-1042-46AD-83D8-765AF4C9BCD9",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6218A006-1F60-4E29-85CC-7D1BCBD7C734",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B863572-CECF-47DF-AF6F-C25F88200DBE",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "59BEBB0E-8C6E-4663-9E0C-E755C2EF0041",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1303D987-4A44-4F33-992E-0C7E683EC7A9",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E7D8E09-D97D-45FF-9AD0-A9B0A846E600",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D9C64FB-A613-4940-86E6-95431B907159",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5C50D4A-EB32-4BE4-B9E6-D25494E2EF55",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFF2EF59-F451-490D-A7AF-E66D11493948",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema de Restricci\u00f3n Inapropiada de Intentos de Autenticaci\u00f3n Excesivos en los controladores l\u00f3gicos programables MicroLogix 1100 1763-L16AWA, Series A y B, versi\u00f3n 16.00 y anteriores ; 1763-L16BBB, Serie A y B, versi\u00f3n 16.00 y anteriores; 1763-L16BWA, Serie A y B, versi\u00f3n 16.00 y anteriores; y 1763-L16DWD, Series A y B, versi\u00f3n 16.00 y anteriores de Allen-Bradley en Rockwell Automation y controladores l\u00f3gicos programables MicroLogix 1400 1766-L32AWA, Series A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BWA, Serie A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BWAA, Serie A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BXB, Serie A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BXBA, Serie A y B, versi\u00f3n 16.00 y anteriores; y 1766-L32AWAA, Series A y B, versi\u00f3n 16.00 y anteriores de Allen-Bradley en Rockwell Automation . No se presentan penalizaciones por introducir repetidamente contrase\u00f1as inapropiadas."
    }
  ],
  "id": "CVE-2017-7898",
  "lastModified": "2026-06-17T01:25:25.373",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2017-7898",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-06-03T13:20:17.293957Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2017-06-30T03:29:00.703",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.securitytracker.com/id/1038546"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securitytracker.com/id/1038546"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-307"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-307"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…