GSD-2020-26077
Vulnerability from gsd - Updated: 2023-12-13 01:22Details
A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2020-26077",
"description": "A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.",
"id": "GSD-2020-26077"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-26077"
],
"details": "A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.",
"id": "GSD-2020-26077",
"modified": "2023-12-13T01:22:08.903215Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2020-11-18T16:00:00",
"ID": "CVE-2020-26077",
"STATE": "PUBLIC",
"TITLE": "Cisco IoT Field Network Director Improper Access Control Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IoT Field Network Director (IoT-FND) ",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system."
}
]
},
"exploit": [
{
"lang": "eng",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
}
],
"impact": {
"cvss": {
"baseScore": "5.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N ",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet"
}
]
},
"source": {
"advisory": "cisco-sa-FND-LV-hE4Rntet",
"defect": [
[
"CSCvt45262"
]
],
"discovery": "INTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.6.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2020-26077"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability",
"refsource": "CISCO",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4
}
},
"lastModifiedDate": "2020-11-25T17:48Z",
"publishedDate": "2020-11-18T18:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…