Summary
A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Cisco | Cisco IoT Field Network Director (IoT-FND) |
Version: n/a |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:49:07.114Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2020-26077", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-13T17:22:17.281138Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-13T17:39:33.443Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco IoT Field Network Director (IoT-FND)", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2020-11-18T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-11-18T17:40:32", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet" } ], "source": { "advisory": "cisco-sa-FND-LV-hE4Rntet", "defect": [ [ "CSCvt45262" ] ], "discovery": "INTERNAL" }, "title": "Cisco IoT Field Network Director Improper Access Control Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-11-18T16:00:00", "ID": "CVE-2020-26077", "STATE": "PUBLIC", "TITLE": "Cisco IoT Field Network Director Improper Access Control Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco IoT Field Network Director (IoT-FND)", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "5.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284" } ] } ] }, "references": { "reference_data": [ { "name": "20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet" } ] }, "source": { "advisory": "cisco-sa-FND-LV-hE4Rntet", "defect": [ [ "CSCvt45262" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2020-26077", "datePublished": "2020-11-18T17:40:32.927009Z", "dateReserved": "2020-09-24T00:00:00", "dateUpdated": "2024-11-13T17:39:33.443Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.6.1\", \"matchCriteriaId\": \"0D507A4F-4079-4B68-997E-88901E063348\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la funcionalidad access control de Cisco IoT Field Network Director (FND), podr\\u00eda permitir a un atacante remoto autenticado visualizar listas de usuarios de diferentes dominios configurados en un sistema afectado.\u0026#xa0;La vulnerabilidad es debido a un control de acceso inapropiado.\u0026#xa0;Un atacante podr\\u00eda explotar esta vulnerabilidad mediante el env\\u00edo de una petici\\u00f3n a la API que modifique el dominio de una lista de usuarios solicitada en un sistema afectado.\u0026#xa0;Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante visualizar listas de usuarios de diferentes dominios en el sistema afectado\"}]", "id": "CVE-2020-26077", "lastModified": "2024-11-21T05:19:11.197", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 1.4}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\", \"baseScore\": 5.0, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.1, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:N/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2020-11-18T18:15:11.810", "references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "ykramarz@cisco.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-26077\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-11-18T18:15:11.810\",\"lastModified\":\"2024-11-21T05:19:11.197\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la funcionalidad access control de Cisco IoT Field Network Director (FND), podr\u00eda permitir a un atacante remoto autenticado visualizar listas de usuarios de diferentes dominios configurados en un sistema afectado.\u0026#xa0;La vulnerabilidad es debido a un control de acceso inapropiado.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de una petici\u00f3n a la API que modifique el dominio de una lista de usuarios solicitada en un sistema afectado.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante visualizar listas de usuarios de diferentes dominios en el sistema afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.1,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.6.1\",\"matchCriteriaId\":\"0D507A4F-4079-4B68-997E-88901E063348\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T15:49:07.114Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-26077\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-13T17:22:17.281138Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-13T17:26:01.657Z\"}}], \"cna\": {\"title\": \"Cisco IoT Field Network Director Improper Access Control Vulnerability\", \"source\": {\"defect\": [[\"CSCvt45262\"]], \"advisory\": \"cisco-sa-FND-LV-hE4Rntet\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco IoT Field Network Director (IoT-FND)\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2020-11-18T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2020-11-18T17:40:32\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"5.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\"}}, \"source\": {\"defect\": [[\"CSCvt45262\"]], \"advisory\": \"cisco-sa-FND-LV-hE4Rntet\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco IoT Field Network Director (IoT-FND)\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-LV-hE4Rntet\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Access Control Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the access control functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to view lists of users from different domains that are configured on an affected system. The vulnerability is due to improper access control. An attacker could exploit this vulnerability by sending an API request that alters the domain for a requested user list on an affected system. A successful exploit could allow the attacker to view lists of users from different domains on the affected system.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-284\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-26077\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco IoT Field Network Director Improper Access Control Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2020-11-18T16:00:00\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2020-26077\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-13T17:39:33.443Z\", \"dateReserved\": \"2020-09-24T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2020-11-18T17:40:32.927009Z\", \"assignerShortName\": \"cisco\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.