GSD-2020-7523
Vulnerability from gsd - Updated: 2023-12-13 01:21Details
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2020-7523",
"description": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.",
"id": "GSD-2020-7523"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7523"
],
"details": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.",
"id": "GSD-2020-7523",
"modified": "2023-12-13T01:21:52.126911Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7523",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
"version": {
"version_data": [
{
"version_value": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269: Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:modbus_driver_suite:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.15.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:x86:*",
"cpe_name": [],
"versionEndExcluding": "2.20_ie_30",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:x64:*",
"cpe_name": [],
"versionEndExcluding": "3.20_ie_30",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7523"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.4,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.1,
"impactScore": 6.0
}
},
"lastModifiedDate": "2021-06-04T14:16Z",
"publishedDate": "2020-08-31T17:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…