GSD-2021-1583

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2021-1583",
    "description": "A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device.",
    "id": "GSD-2021-1583"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-1583"
      ],
      "details": "A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device.",
      "id": "GSD-2021-1583",
      "modified": "2023-12-13T01:23:22.969906Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@cisco.com",
        "DATE_PUBLIC": "2021-08-25T16:00:00",
        "ID": "CVE-2021-1583",
        "STATE": "PUBLIC",
        "TITLE": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Cisco NX-OS System Software in ACI Mode ",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Cisco"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device."
          }
        ]
      },
      "exploit": [
        {
          "lang": "eng",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
        }
      ],
      "impact": {
        "cvss": {
          "baseScore": "4.4",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N ",
          "version": "3.0"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-284"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability",
            "refsource": "CISCO",
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-naci-afr-UtjfO2D7"
          }
        ]
      },
      "source": {
        "advisory": "cisco-sa-naci-afr-UtjfO2D7",
        "defect": [
          [
            "CSCvy05010"
          ]
        ],
        "discovery": "INTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:14.2\\(7f\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx3p:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2021-1583"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability",
              "refsource": "CISCO",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-naci-afr-UtjfO2D7"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "LOW",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 0.8,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2022-10-21T19:33Z",
      "publishedDate": "2021-08-25T20:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.