cve-2021-1583
Vulnerability from cvelistv5
Published
2021-08-25 19:10
Modified
2024-11-07 22:02
Summary
Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T16:18:10.371Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-naci-afr-UtjfO2D7"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-1583",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-07T21:40:54.721873Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-07T22:02:44.390Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco NX-OS System Software in ACI Mode",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-08-25T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-25T19:10:48",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-naci-afr-UtjfO2D7"
        }
      ],
      "source": {
        "advisory": "cisco-sa-naci-afr-UtjfO2D7",
        "defect": [
          [
            "CSCvy05010"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2021-08-25T16:00:00",
          "ID": "CVE-2021-1583",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco NX-OS System Software in ACI Mode",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "4.4",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Arbitrary File Read Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-naci-afr-UtjfO2D7"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-naci-afr-UtjfO2D7",
          "defect": [
            [
              "CSCvy05010"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2021-1583",
    "datePublished": "2021-08-25T19:10:48.311346Z",
    "dateReserved": "2020-11-13T00:00:00",
    "dateUpdated": "2024-11-07T22:02:44.390Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-1583\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2021-08-25T20:15:10.997\",\"lastModified\":\"2023-11-07T03:28:42.050\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the fabric infrastructure file system access control of Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to read arbitrary files on an affected system. This vulnerability is due to improper access control. An attacker with Administrator privileges could exploit this vulnerability by executing a specific vulnerable command on an affected device. A successful exploit could allow the attacker to read arbitrary files on the file system of the affected device.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en el control de acceso al sistema de archivos de la infraestructura de f\u00e1brica de Cisco Nexus 9000 Series Fabric Switches en el modo Application Centric Infrastructure (ACI) podr\u00eda permitir a un atacante local autenticado leer archivos arbitrarios en un sistema afectado. Esta vulnerabilidad es debido a un control de acceso inapropiado. Un atacante con privilegios de Administrador podr\u00eda explotar esta vulnerabilidad al ejecutar un comando vulnerable espec\u00edfico en un dispositivo afectado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante leer archivos arbitrarios en el sistema de archivos del dispositivo afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.1},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:14.2\\\\(7f\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD6D7D62-660F-49AB-96D7-189778A42394\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8EBEBA5B-5589-417B-BF3B-976083E9FE54\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CD9C1F1-8582-4F67-A77D-97CBFECB88B8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4283E433-7F8C-4410-B565-471415445811\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F80AB6FB-32FD-43D7-A9F1-80FA47696210\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D5B2E4C1-2627-4B9D-8E92-4B483F647651\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"557ED31C-C26A-4FAE-8B14-D06B49F7F08B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11411BFD-3F4D-4309-AB35-A3629A360FB0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E663DE91-C86D-48DC-B771-FA72A8DF7A7C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A90184B3-C82F-4CE5-B2AD-97D5E4690871\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40E40F42-632A-47DF-BE33-DC25B826310B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4AB89849-6DA4-4C9D-BC3F-EE0E41FD1901\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C47F6BF9-2ADB-41A4-8D7D-8BB00141BB23\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx3p:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BBEF7F26-BB47-44BD-872E-130820557C23\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07DE6F63-2C7D-415B-8C34-01EC05C062F3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F423E45D-A6DD-4305-9C6A-EAB26293E53A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"102F91CD-DFB6-43D4-AE5B-DA157A696230\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E952A96A-0F48-4357-B7DD-1127D8827650\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F70D81F1-8B12-4474-9060-B4934D8A3873\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5394DE31-3863-4CA9-B7B1-E5227183100D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7349D69B-D8FA-4462-AA28-69DD18A652D9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE4BB834-2C00-4384-A78E-AF3BCDDC58AF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0D30D52-837F-4FDA-B8E5-A9066E9C6D2F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CE49B45-F2E9-491D-9C29-1B46E9CE14E2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1CC5F78-E88B-4B82-9E3E-C73D3A49DE26\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"91231DC6-2773-4238-8C14-A346F213B5E5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DF88547-BAF4-47B0-9F60-80A30297FCEB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"113772B6-E9D2-4094-9468-3F4E1A87D07D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C45A38D6-BED6-4FEF-AD87-A1E813695DE0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1FC2B1F-232E-4754-8076-CC82F3648730\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CDD27C9-5EAF-4956-8AB7-740C84C9D4FC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17C7E3DB-8E1A-47AD-B1C5-61747DC0CFB9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CF467E2-4567-426E-8F48-39669E0F514C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63842B25-8C32-4988-BBBD-61E9CB09B4F3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68EA1FEF-B6B6-49FE-A0A4-5387F76303F8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4364ADB9-8162-451D-806A-B98924E6B2CF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B53BCB42-ED61-4FCF-8068-CB467631C63C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49E0371B-FDE2-473C-AA59-47E1269D050F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"489D11EC-5A18-4F32-BC7C-AC1FCEC27222\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BC5293E-F2B4-46DC-85DA-167EA323FCFD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA022E77-6557-4A33-9A3A-D028E2DB669A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDC2F709-AFBE-48EA-A3A2-DA1134534FB6\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-naci-afr-UtjfO2D7\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.