GSD-2023-29411
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow
changes to administrative credentials, leading to potential remote code execution without
requiring prior authentication on the Java RMI interface.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-29411",
"id": "GSD-2023-29411"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-29411"
],
"details": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n",
"id": "GSD-2023-29411",
"modified": "2023-12-13T01:20:56.927418Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2023-29411",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V2.5-GA-01-22320",
"version_value": "prior"
}
]
}
},
{
"product_name": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V2.5-GS-01-22320",
"version_value": "prior"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-306",
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2023-29411"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf",
"refsource": "MISC",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-04-28T13:31Z",
"publishedDate": "2023-04-18T21:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…