CVE-2023-29411
Vulnerability from cvelistv5
Published
2023-04-18 20:49
Modified
2024-08-02 14:07
Severity ?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:07:46.023Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "prior",
              "status": "affected",
              "version": "V2.5-GA-01-22320",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "prior",
              "status": "affected",
              "version": "V2.5-GS-01-22320",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-04-11T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
            }
          ],
          "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-18T20:49:34.059Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-29411",
    "datePublished": "2023-04-18T20:49:34.059Z",
    "dateReserved": "2023-04-05T20:35:41.367Z",
    "dateUpdated": "2024-08-02T14:07:46.023Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-29411\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-04-18T21:15:09.390\",\"lastModified\":\"2023-04-28T13:31:57.647\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\\nchanges to administrative credentials, leading to potential remote code execution without\\nrequiring prior authentication on the Java RMI interface. \\n\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-ga-01-22320\",\"matchCriteriaId\":\"D52617D6-0503-4B6B-A59D-441E0D1F4296\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-gs-01-22320\",\"matchCriteriaId\":\"1849E03C-445A-4225-AECD-B4A7502F5F3B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.