icsa-21-238-03
Vulnerability from csaf_cisa
Published
2021-08-26 00:00
Modified
2022-03-22 00:00
Summary
Delta Electronics DIAEnergie (Update C)
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to retrieve passwords in cleartext, remotely execute code, cause a user to carry out an action unintentionally, or log in and use the device with administrative privileges.
Critical infrastructure sectors
Critical Manufacturing
Countries/areas deployed
Worldwide
Company headquarters location
Taiwan
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to retrieve passwords in cleartext, remotely execute code, cause a user to carry out an action unintentionally, or log in and use the device with administrative privileges.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Taiwan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-238-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-238-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-238-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-238-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams_0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" } ], "title": "Delta Electronics DIAEnergie (Update C)", "tracking": { "current_release_date": "2022-03-22T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-238-03", "initial_release_date": "2021-08-26T00:00:00.000000Z", "revision_history": [ { "date": "2021-08-26T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-238-03 Delta Electronics DIAEnergie" }, { "date": "2021-12-16T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-21-238-03 Delta Electronics DIAEnergie (Update A)" }, { "date": "2022-03-22T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-21-238-03 Delta Electronics DIAEnergie (Update B)" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 1.9", "product": { "name": "DIAEnergie: All versions prior to 1.9", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "DIAEnergie" } ], "category": "vendor", "name": "Delta Electronics" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-33003", "cwe": { "id": "CWE-916", "name": "Use of Password Hash With Insufficient Computational Effort" }, "notes": [ { "category": "summary", "text": "The affected product may allow an attacker to retrieve passwords in cleartext due to a weak hashing algorithm. CVE-2021-33003 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-33003" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32967", "cwe": { "id": "CWE-288", "name": "Authentication Bypass Using an Alternate Path or Channel" }, "notes": [ { "category": "summary", "text": "The affected product may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges. CVE-2021-32967 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32967" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32955", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "The affected product allows unrestricted file uploads, which may allow an attacker to remotely execute code. CVE-2021-32955 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32955" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32983", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\\MSSQLSERVER. CVE-2021-32983 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32983" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-38390", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\\MSSQLSERVER. CVE-2021-38390has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-38390" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-38391", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A Blind SQL injection vulnerability exists in the /DataHandler/AM/AM_Handler.ashx endpoint. The application does not properly validate the user-controlled value supplied through the parameter type before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\\MSSQLSERVER. CVE-2021-38391has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-38391" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-38393", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\\MSSQLSERVER. CVE-2021-38393has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-38393" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32991", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to cross-site request forgery, which may allow an attacker to cause a user to carry out an action unintentionally. CVE-2021-32991 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32991" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-23228", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to a reflected cross-site scripting attack through error pages that are returned by .NET Request.QueryString. CVE-2021-23228 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-23228" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-44544", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to multiple cross-site scripting vulnerabilities when arbitrary code is injected into the parameter name of the script HandlerEnergyType.ashx. CVE-2021-44544 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44544" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-31558", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter descr of the script DIAE_hierarchyHandler.ashx. CVE-2021-31558 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31558" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-44471", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter name of the script DIAE_HandlerAlarmGroup.ashx. CVE-2021-44471 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44471" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-0988", "cwe": { "id": "CWE-319", "name": "Cleartext Transmission of Sensitive Information" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product. CVE-2022-0988 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0988" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta Electronics has fixed the reported vulnerabilities and recommends users upgrade to version 1.9 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026q=DIAEnergie%20V1.9\u0026sort_expr=cdate\u0026sort_dir=DESC" } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.