SSA-148078
Vulnerability from csaf_siemens - Published: 2017-10-12 00:00 - Updated: 2022-06-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
APOGEE PXC Compact (BACnet)
Siemens / APOGEE PXC Compact (BACnet)
|
< V3.5 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
APOGEE PXC Compact (P2 Ethernet)
Siemens / APOGEE PXC Compact (P2 Ethernet)
|
vers:all/* |
Mitigation
No Fix Planned
Mitigation
Mitigation
|
|
|
APOGEE PXC Modular (BACnet)
Siemens / APOGEE PXC Modular (BACnet)
|
< V3.5 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
APOGEE PXC Modular (P2 Ethernet)
Siemens / APOGEE PXC Modular (P2 Ethernet)
|
vers:all/* |
Mitigation
No Fix Planned
Mitigation
Mitigation
|
|
|
TALON TC Compact (BACnet)
Siemens / TALON TC Compact (BACnet)
|
< V3.5 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
TALON TC Modular (BACnet)
Siemens / TALON TC Modular (BACnet)
|
< V3.5 |
Vendor Fix
fix
Mitigation
Mitigation
|
{
"document": {
"acknowledgments": [
{
"organization": "RoseSecurity",
"summary": "reporting the vulnerabilities for APOGEE PXC Series (P2 Ethernet) devices."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Multiple vulnerabilities in the APOGEE PXC and TALON TC series of products could allow unauthenticated attackers to download sensitive information through the integrated webserver.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-148078: Multiple Vulnerabilities in APOGEE/TALON Field Panels - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
},
{
"category": "self",
"summary": "SSA-148078: Multiple Vulnerabilities in APOGEE/TALON Field Panels - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-148078.txt"
},
{
"category": "self",
"summary": "SSA-148078: Multiple Vulnerabilities in APOGEE/TALON Field Panels - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-148078.json"
}
],
"title": "SSA-148078: Multiple Vulnerabilities in APOGEE/TALON Field Panels",
"tracking": {
"current_release_date": "2022-06-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-148078",
"initial_release_date": "2017-10-12T00:00:00Z",
"revision_history": [
{
"date": "2017-10-12T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added APOGEE PXC Series (P2 Ethernet) devices"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.5",
"product": {
"name": "APOGEE PXC Compact (BACnet)",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "APOGEE PXC Compact (BACnet)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "APOGEE PXC Compact (P2 Ethernet)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "APOGEE PXC Compact (P2 Ethernet)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.5",
"product": {
"name": "APOGEE PXC Modular (BACnet)",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "APOGEE PXC Modular (BACnet)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "APOGEE PXC Modular (P2 Ethernet)",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "APOGEE PXC Modular (P2 Ethernet)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.5",
"product": {
"name": "TALON TC Compact (BACnet)",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "TALON TC Compact (BACnet)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.5",
"product": {
"name": "TALON TC Modular (BACnet)",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "TALON TC Modular (BACnet)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-9946",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2017-9946 - APOGEE PXC Compact (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9946 - APOGEE PXC Modular (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9946 - TALON TC Compact (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9946 - TALON TC Modular (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9946 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2017-9946.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.5 or later version",
"product_ids": [
"1",
"3",
"5",
"6"
],
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"category": "mitigation",
"details": "Disable the integrated webserver",
"product_ids": [
"2",
"4"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"2",
"4"
]
},
{
"category": "mitigation",
"details": "Siemens recommends to disable the integrated webserver when not in use",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "mitigation",
"details": "Please contact your local Siemens office for additional support",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2017-9946"
},
{
"cve": "CVE-2017-9947",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2017-9947 - APOGEE PXC Compact (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9947 - APOGEE PXC Modular (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9947 - TALON TC Compact (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9947 - TALON TC Modular (BACnet)",
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"summary": "CVE-2017-9947 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2017-9947.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.5 or later version",
"product_ids": [
"1",
"3",
"5",
"6"
],
"url": "https://partnerportal.extranet.dc.siemens.com/"
},
{
"category": "mitigation",
"details": "Disable the integrated webserver",
"product_ids": [
"2",
"4"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"2",
"4"
]
},
{
"category": "mitigation",
"details": "Siemens recommends to disable the integrated webserver when not in use",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "mitigation",
"details": "Please contact your local Siemens office for additional support",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2017-9947"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.