Search criteria

9 vulnerabilities found for powerflex_manager by dell

CVE-2025-36599 (GCVE-0-2025-36599)

Vulnerability from nvd – Published: 2025-07-09 18:30 – Updated: 2025-07-09 19:19
VLAI?
Summary
Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
Dell PowerFlex Manager VM Affected: N/A , < 4.6.2.1 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-36599",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T19:19:01.008011Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-09T19:19:13.688Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerFlex Manager VM",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.6.2.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-07-07T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account."
            }
          ],
          "value": "Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-09T18:31:44.914Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000342158/dsa-2025-279-security-update-for-dell-powerflex-manager-platform-pfmp-proprietary-code-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-36599",
    "datePublished": "2025-07-09T18:30:31.566Z",
    "dateReserved": "2025-04-15T21:32:11.414Z",
    "dateUpdated": "2025-07-09T19:19:13.688Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37143 (GCVE-0-2024-37143)

Vulnerability from nvd – Published: 2024-12-10 02:25 – Updated: 2024-12-11 17:16
VLAI?
Summary
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system.
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
Vendor Product Version
Dell Dell PowerFlex appliance Affected: N/A , < 46.381.00 (semver)
Affected: N/A , < 46.376.00 (semver)
Create a notification for this product.
    Dell Dell PowerFlex rack Affected: N/A , < 3.8.1.0 (semver)
Affected: N/A , < 3.7.6.0 (semver)
Create a notification for this product.
    Dell Dell PowerFlex custom node Affected: N/A , < 4.6.1.0 (semver)
Create a notification for this product.
    Dell Dell InsightIQ Affected: N/A , < 5.1.1 (semver)
Create a notification for this product.
    Dell Dell Data Lakehouse Affected: N/A , < 1.2.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37143",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-11T17:15:39.353490Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-11T17:16:29.723Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex appliance",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "46.381.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "46.376.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex rack",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "3.8.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "3.7.6.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex custom node",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell InsightIQ",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell Data Lakehouse",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-12-09T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
            }
          ],
          "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T02:25:33.225Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFor remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dell.com/support/kbdoc/en-us/000231116\"\u003eKB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;(customer login required).\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "For remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference  KB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143 https://www.dell.com/support/kbdoc/en-us/000231116 \u00a0(customer login required)."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37143",
    "datePublished": "2024-12-10T02:25:33.225Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-12-11T17:16:29.723Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37144 (GCVE-0-2024-37144)

Vulnerability from nvd – Published: 2024-12-10 02:11 – Updated: 2024-12-10 21:27
VLAI?
Summary
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster.
CWE
  • CWE-922 - Insecure Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Dell Dell PowerFlex appliance Affected: N/A , < 46.381.00 (semver)
Affected: N/A , < 46.376.00 (semver)
Create a notification for this product.
    Dell Dell PowerFlex rack Affected: N/A , < 3.8.1.0 (semver)
Affected: N/A , < 3.7.6.0 (semver)
Create a notification for this product.
    Dell Dell PowerFlex custom node Affected: N/A , < 4.6.1.0 (semver)
Create a notification for this product.
    Dell Dell InsightIQ Affected: N/A , < 5.1.1 (semver)
Create a notification for this product.
    Dell Dell Data Lakehouse Affected: N/A , < 1.2.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37144",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-10T21:27:12.499475Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-10T21:27:23.301Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex appliance",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "46.381.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "46.376.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex rack",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "3.8.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "3.7.6.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex custom node",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell InsightIQ",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell Data Lakehouse",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-12-09T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster."
            }
          ],
          "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-922",
              "description": "CWE-922: Insecure Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T02:11:13.298Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37144",
    "datePublished": "2024-12-10T02:11:13.298Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-12-10T21:27:23.301Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

FKIE_CVE-2025-36599

Vulnerability from fkie_nvd - Published: 2025-07-09 19:15 - Updated: 2026-01-16 15:00
Summary
Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account.
Impacted products
Vendor Product Version
dell powerflex_manager *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "365B0B2C-5865-477C-938A-EC4CFFFF6E96",
              "versionEndExcluding": "4.6.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account."
    },
    {
      "lang": "es",
      "value": "Dell PowerFlex Manager VM, versiones anteriores a la 4.6.2.1, contiene una vulnerabilidad de inserci\u00f3n de informaci\u00f3n confidencial en el archivo de registro. Un atacante con pocos privilegios y acceso remoto podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda la divulgaci\u00f3n de ciertas credenciales de usuario. El atacante podr\u00eda usar las credenciales expuestas para acceder al sistema con los privilegios de la cuenta comprometida."
    }
  ],
  "id": "CVE-2025-36599",
  "lastModified": "2026-01-16T15:00:37.263",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2025-07-09T19:15:24.207",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000342158/dsa-2025-279-security-update-for-dell-powerflex-manager-platform-pfmp-proprietary-code-vulnerability"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-37144

Vulnerability from fkie_nvd - Published: 2024-12-10 03:15 - Updated: 2026-01-22 16:16
Summary
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:data_lakehouse:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80278A58-A1BB-4CD1-93B7-2BEC2D227FCC",
              "versionEndExcluding": "1.2.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:insightiq:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0544C44D-29E4-45AB-A12B-B05F0A2ECC14",
              "versionEndExcluding": "5.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_appliance_intelligent_catalog:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "680FAFDC-0CF1-4B01-B0AF-6775389B33A4",
              "versionEndExcluding": "46.376.00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44B7F933-3F65-4B22-9EC6-323B4ED600A1",
              "versionEndExcluding": "4.6.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_rack_release_certification_matrix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "427C3C57-3812-4951-A6F6-2D598391B633",
              "versionEndExcluding": "3.7.6.0",
              "versionStartIncluding": "3.7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_rack_release_certification_matrix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3A561D-15B4-47E4-B578-F21DA37D3830",
              "versionEndExcluding": "3.8.1.0",
              "versionStartIncluding": "3.8.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster."
    },
    {
      "lang": "es",
      "value": "Las versiones del dispositivo Dell PowerFlex anteriores a IC 46.381.00 e IC 46.376.00, las versiones del rack Dell PowerFlex anteriores a RCM 3.8.1.0 (para el tren RCM 3.8.x) y anteriores a RCM 3.7.6.0 (para el tren RCM 3.7.x), el nodo personalizado Dell PowerFlex que utiliza versiones de PowerFlex Manager anteriores a 4.6.1.0, las versiones de Dell InsightIQ anteriores a 5.1.1 y las versiones de Dell Data Lakehouse anteriores a 1.2.0.0 contienen una vulnerabilidad de almacenamiento inseguro de informaci\u00f3n confidencial. Un atacante con privilegios elevados y acceso local podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda la divulgaci\u00f3n de informaci\u00f3n. El atacante podr\u00eda utilizar la informaci\u00f3n divulgada para obtener acceso no autorizado a los pods dentro del cl\u00faster."
    }
  ],
  "id": "CVE-2024-37144",
  "lastModified": "2026-01-22T16:16:45.403",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.5,
        "impactScore": 6.0,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-12-10T03:15:05.730",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-922"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-37143

Vulnerability from fkie_nvd - Published: 2024-12-10 03:15 - Updated: 2026-01-22 16:24
Summary
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:data_lakehouse:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80278A58-A1BB-4CD1-93B7-2BEC2D227FCC",
              "versionEndExcluding": "1.2.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:insightiq:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0544C44D-29E4-45AB-A12B-B05F0A2ECC14",
              "versionEndExcluding": "5.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_appliance_intelligent_catalog:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "680FAFDC-0CF1-4B01-B0AF-6775389B33A4",
              "versionEndExcluding": "46.376.00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44B7F933-3F65-4B22-9EC6-323B4ED600A1",
              "versionEndExcluding": "4.6.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_rack_release_certification_matrix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "427C3C57-3812-4951-A6F6-2D598391B633",
              "versionEndExcluding": "3.7.6.0",
              "versionStartIncluding": "3.7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:powerflex_rack_release_certification_matrix:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3A561D-15B4-47E4-B578-F21DA37D3830",
              "versionEndExcluding": "3.8.1.0",
              "versionStartIncluding": "3.8.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
    },
    {
      "lang": "es",
      "value": "Las versiones del dispositivo Dell PowerFlex anteriores a IC 46.381.00 e IC 46.376.00, las versiones de bastidor de Dell PowerFlex anteriores a RCM 3.8.1.0 (para el tren RCM 3.8.x) y anteriores a RCM 3.7.6.0 (para el tren RCM 3.7.x), el nodo personalizado de Dell PowerFlex que utiliza versiones de PowerFlex Manager anteriores a 4.6.1.0, las versiones de Dell InsightIQ anteriores a 5.1.1 y las versiones de Dell Data Lakehouse anteriores a 1.2.0.0 contienen una vulnerabilidad de resoluci\u00f3n de v\u00ednculo incorrecta antes del acceso a archivos. Un atacante no autenticado con acceso remoto podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario en el sistema."
    }
  ],
  "id": "CVE-2024-37143",
  "lastModified": "2026-01-22T16:24:36.057",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-12-10T03:15:05.573",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-59"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    }
  ]
}

CVE-2025-36599 (GCVE-0-2025-36599)

Vulnerability from cvelistv5 – Published: 2025-07-09 18:30 – Updated: 2025-07-09 19:19
VLAI?
Summary
Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
Dell PowerFlex Manager VM Affected: N/A , < 4.6.2.1 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-36599",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T19:19:01.008011Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-09T19:19:13.688Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerFlex Manager VM",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.6.2.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-07-07T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account."
            }
          ],
          "value": "Dell PowerFlex Manager VM, versions prior to 4.6.2.1, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-09T18:31:44.914Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000342158/dsa-2025-279-security-update-for-dell-powerflex-manager-platform-pfmp-proprietary-code-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-36599",
    "datePublished": "2025-07-09T18:30:31.566Z",
    "dateReserved": "2025-04-15T21:32:11.414Z",
    "dateUpdated": "2025-07-09T19:19:13.688Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37143 (GCVE-0-2024-37143)

Vulnerability from cvelistv5 – Published: 2024-12-10 02:25 – Updated: 2024-12-11 17:16
VLAI?
Summary
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system.
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
Vendor Product Version
Dell Dell PowerFlex appliance Affected: N/A , < 46.381.00 (semver)
Affected: N/A , < 46.376.00 (semver)
Create a notification for this product.
    Dell Dell PowerFlex rack Affected: N/A , < 3.8.1.0 (semver)
Affected: N/A , < 3.7.6.0 (semver)
Create a notification for this product.
    Dell Dell PowerFlex custom node Affected: N/A , < 4.6.1.0 (semver)
Create a notification for this product.
    Dell Dell InsightIQ Affected: N/A , < 5.1.1 (semver)
Create a notification for this product.
    Dell Dell Data Lakehouse Affected: N/A , < 1.2.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37143",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-11T17:15:39.353490Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-11T17:16:29.723Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex appliance",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "46.381.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "46.376.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex rack",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "3.8.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "3.7.6.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex custom node",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell InsightIQ",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell Data Lakehouse",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-12-09T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
            }
          ],
          "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T02:25:33.225Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFor remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dell.com/support/kbdoc/en-us/000231116\"\u003eKB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;(customer login required).\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "For remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference  KB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143 https://www.dell.com/support/kbdoc/en-us/000231116 \u00a0(customer login required)."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37143",
    "datePublished": "2024-12-10T02:25:33.225Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-12-11T17:16:29.723Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37144 (GCVE-0-2024-37144)

Vulnerability from cvelistv5 – Published: 2024-12-10 02:11 – Updated: 2024-12-10 21:27
VLAI?
Summary
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster.
CWE
  • CWE-922 - Insecure Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Dell Dell PowerFlex appliance Affected: N/A , < 46.381.00 (semver)
Affected: N/A , < 46.376.00 (semver)
Create a notification for this product.
    Dell Dell PowerFlex rack Affected: N/A , < 3.8.1.0 (semver)
Affected: N/A , < 3.7.6.0 (semver)
Create a notification for this product.
    Dell Dell PowerFlex custom node Affected: N/A , < 4.6.1.0 (semver)
Create a notification for this product.
    Dell Dell InsightIQ Affected: N/A , < 5.1.1 (semver)
Create a notification for this product.
    Dell Dell Data Lakehouse Affected: N/A , < 1.2.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37144",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-10T21:27:12.499475Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-10T21:27:23.301Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex appliance",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "46.381.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "46.376.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex rack",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "3.8.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "3.7.6.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell PowerFlex custom node",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell InsightIQ",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell Data Lakehouse",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-12-09T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster."
            }
          ],
          "value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-922",
              "description": "CWE-922: Insecure Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T02:11:13.298Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37144",
    "datePublished": "2024-12-10T02:11:13.298Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-12-10T21:27:23.301Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}