CVE-2019-14891
Vulnerability from cvelistv5
Published
2019-11-25 10:31
Modified
2024-08-05 00:26
Summary
A flaw was found in cri-o, as a result of all pod-related processes being placed in the same memory cgroup. This can result in container management (conmon) processes being killed if a workload process triggers an out-of-memory (OOM) condition for the cgroup. An attacker could abuse this flaw to get host network access on an cri-o host.
References
Impacted products
n/acri-o
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:26:39.148Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14891"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cri-o",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw was found in cri-o, as a result of all pod-related processes being placed in the same memory cgroup. This can result in container management (conmon) processes being killed if a workload process triggers an out-of-memory (OOM) condition for the cgroup. An attacker could abuse this flaw to get host network access on an cri-o host."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-460",
              "description": "CWE-460",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-25T10:31:17",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14891"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2019-14891",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cri-o",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A flaw was found in cri-o, as a result of all pod-related processes being placed in the same memory cgroup. This can result in container management (conmon) processes being killed if a workload process triggers an out-of-memory (OOM) condition for the cgroup. An attacker could abuse this flaw to get host network access on an cri-o host."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "5/CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-460"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14891",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14891"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2019-14891",
    "datePublished": "2019-11-25T10:31:17",
    "dateReserved": "2019-08-10T00:00:00",
    "dateUpdated": "2024-08-05T00:26:39.148Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-14891\",\"sourceIdentifier\":\"secalert@redhat.com\",\"published\":\"2019-11-25T11:15:11.430\",\"lastModified\":\"2020-02-28T18:10:54.500\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A flaw was found in cri-o, as a result of all pod-related processes being placed in the same memory cgroup. This can result in container management (conmon) processes being killed if a workload process triggers an out-of-memory (OOM) condition for the cgroup. An attacker could abuse this flaw to get host network access on an cri-o host.\"},{\"lang\":\"es\",\"value\":\"Se encontr\u00f3 un fallo en cri-o, como un resultado de que todos los procesos relacionados con pod est\u00e1n colocados en el mismo grupo de memoria. Esto puede resultar en que se eliminen los procesos de administraci\u00f3n de contenedores (conmon) si un proceso de carga de trabajo desencadena una condici\u00f3n de falta de memoria (OOM) para el cgroup. Un atacante podr\u00eda abusar de este fallo para conseguir acceso a la red del host en un host de cri-o.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.6,\"impactScore\":3.4}],\"cvssMetricV30\":[{\"source\":\"secalert@redhat.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.6,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]},{\"source\":\"secalert@redhat.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-460\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:kubernetes:cri-o:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.16.1\",\"matchCriteriaId\":\"FCFB0237-0650-4471-BAB1-4DF834BCD269\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fedoraproject:fedora:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D3FEADDA-2AEE-4F65-9401-971B585664A8\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:redhat:openshift_container_platform:3.11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F87326E-0B56-4356-A889-73D026DB1D4B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:redhat:openshift_container_platform:4.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"064E7BDD-4EF0-4A0D-A38D-8C75BAFEDCEF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:redhat:openshift_container_platform:4.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C85A84D-A70F-4B02-9E5D-CD9660ABF048\"}]}]}],\"references\":[{\"url\":\"https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14891\",\"source\":\"secalert@redhat.com\",\"tags\":[\"Issue Tracking\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.