Action not permitted
Modal body text goes here.
CVE-2019-1612
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ykramarz@cisco.com | http://www.securityfocus.com/bid/107388 | Third Party Advisory, VDB Entry | |
ykramarz@cisco.com | https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612 | Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T18:20:28.369Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "name": "107388", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/107388" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2019-1612", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-21T19:00:06.696498Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-21T19:43:05.265Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Nexus 3000 Series Switches", "vendor": "Cisco", "versions": [ { "lessThan": "7.0(3)I4(9)", "status": "affected", "version": "unspecified", "versionType": "custom" }, { "lessThan": "7.0(3)I7(4)", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "Nexus 3500 Platform Switches", "vendor": "Cisco", "versions": [ { "lessThan": "7.0(3)I7(4)", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "Nexus 3600 Platform Switches", "vendor": "Cisco", "versions": [ { "lessThan": "7.0(3)F3(5)", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "Nexus 9000 Series Switches in Standalone NX-OS Mode", "vendor": "Cisco", "versions": [ { "lessThan": "7.0(3)I4(9)", "status": "affected", "version": "unspecified", "versionType": "custom" }, { "lessThan": "7.0(3)I7(4)", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "Nexus 9500 R-Series Line Cards and Fabric Modules", "vendor": "Cisco", "versions": [ { "lessThan": "7.0(3)F3(5)", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2019-03-06T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5)." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 4.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-03-14T09:57:01", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "name": "107388", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/107388" } ], "source": { "advisory": "cisco-sa-20190306-nxos-cmdinj-1612", "defect": [ [ "CSCvi42373", "CSCvj12009" ] ], "discovery": "INTERNAL" }, "title": "Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-03-06T16:00:00-0800", "ID": "CVE-2019-1612", "STATE": "PUBLIC", "TITLE": "Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Nexus 3000 Series Switches", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)I4(9)" }, { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)I7(4)" } ] } }, { "product_name": "Nexus 3500 Platform Switches", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)I7(4)" } ] } }, { "product_name": "Nexus 3600 Platform Switches", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)F3(5)" } ] } }, { "product_name": "Nexus 9000 Series Switches in Standalone NX-OS Mode", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)I4(9)" }, { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)I7(4)" } ] } }, { "product_name": "Nexus 9500 R-Series Line Cards and Fabric Modules", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "7.0(3)F3(5)" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5)." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "4.2", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-77" } ] } ] }, "references": { "reference_data": [ { "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "name": "107388", "refsource": "BID", "url": "http://www.securityfocus.com/bid/107388" } ] }, "source": { "advisory": "cisco-sa-20190306-nxos-cmdinj-1612", "defect": [ [ "CSCvi42373", "CSCvj12009" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2019-1612", "datePublished": "2019-03-11T22:00:00Z", "dateReserved": "2018-12-06T00:00:00", "dateUpdated": "2024-11-21T19:43:05.265Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-1612\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-03-11T21:29:00.793\",\"lastModified\":\"2019-10-09T23:47:29.797\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la CLI del software NX-OS de Cisco podr\u00eda permitir a un atacante local autenticado ejecutar comandos arbitrarios en el sistema operativo subyacente de un dispositivo afectado. La vulnerabilidad se debe a una validaci\u00f3n de argumentos insuficiente que se env\u00edan a determinados comandos CLI. Un atacante podr\u00eda explotar esta vulnerabilidad incluyendo entradas maliciosas como el argumento de un comando afectado. Un exploit con \u00e9xito podr\u00eda permitir al atacante ejecutar comandos arbitrarios en el sistema operativo subyacente con privilegios elevados. Un atacante necesitar\u00eda credenciales de administrador v\u00e1lidas para explotar esta vulnerabilidad. Los switches de Nexus 3000 Series se ven afectados en versiones de software anteriores a las 7.0(3)I4(9) y 7.0(3)I7(4). Los switches de Nexus 3500 Platform se ven afectados en versiones de software anteriores a la 7.0(3)I7(4). Los switches de Nexus 3600 Platform se ven afectados en versiones de software anteriores a la 7.0(3)F3(5). Los switches de Nexus 9000 Series en Stand se ven afectados en versiones de software anteriores a la 7.0(3)F3(5).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":4.2,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.2},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)i7\\\\(6\\\\)\",\"matchCriteriaId\":\"ED42A087-971B-4452-BCE0-A237176B5067\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8E1073F-D374-4311-8F12-AD8C72FAA293\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"10FFC5E8-CC5A-4D31-A63A-19E72EC442AB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i5\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)i7\\\\(6\\\\)\",\"matchCriteriaId\":\"8C322689-0DC6-412F-B82F-F64F0B5D68DA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)f3\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)f3\\\\(5\\\\)\",\"matchCriteriaId\":\"AB649123-3091-4A8E-A992-42E7BAE299ED\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97217080-455C-48E4-8CE1-6D5B9485864F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)f3\\\\(5\\\\)\",\"matchCriteriaId\":\"CAB74D2E-06DD-4899-9262-64AAC104A992\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8EBEBA5B-5589-417B-BF3B-976083E9FE54\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)f1\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)f3\\\\(5\\\\)\",\"matchCriteriaId\":\"5C856C77-493C-4543-8958-A9AEBBDCBBDD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63BE0266-1C00-4D6A-AD96-7F82532ABAA7\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/107388\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
cisco-sa-20190306-nxos-cmdinj-1612
Vulnerability from csaf_cisco
Notes
{ "document": { "acknowledgments": [ { "summary": "This vulnerability was found during internal security testing." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "notes": [ { "category": "summary", "text": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device.\r\n\r\nThe vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability.\r\n\r\nCisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.\r\n\r\nThis advisory is available at the following link:\r\nhttps://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612 [\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612\"]\r\n This advisory is part of the March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication, which includes 25 Cisco Security Advisories that describe 26 vulnerabilities. For a complete list of the advisories and links to them, see Cisco Event Response: March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication [\"https://sec.cloudapps.cisco.com/security/center/viewErp.x?alertId=ERP-70757\"].\r\nThis bundle contains several similar CLI command injection vulnerabilities; they differ primarily in which products and software versions are affected. See Details [\"#details\"] for more information.", "title": "Summary" }, { "category": "general", "text": "This vulnerability affects the following Cisco products if they are running a vulnerable release of Cisco NX-OS Software:\r\n\r\nNexus 3000 Series Switches\r\nNexus 3500 Platform Switches\r\nNexus 3600 Platform Switches\r\nNexus 9000 Series Switches in standalone NX-OS mode\r\nNexus 9500 R-Series Line Cards and Fabric Modules\r\n\r\nFor information about which Cisco NX-OS Software releases are vulnerable, see the Fixed Software [\"#fs\"] section of this advisory.\r\n\r\nDetermining the Cisco NX-OS Software Release\r\nAdministrators can check the release of Cisco NX-OS Software that is running on a device by using the show version command in the device CLI. The following example shows the output of this command on a device that is running Cisco NX-OS Software Release 7.0(3)I5(1):\r\n\r\n\r\nnxos-switch# show version\r\nCisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2016, Cisco and/or its affiliates. All rights reserved. The copyrights to certain works contained in this software are owned by other third parties and used and distributed under their own licenses, such as open source. This software is provided \"as is,\" and unless otherwise stated, there is no warranty, express or implied, including but not limited to warranties of merchantability and fitness for a particular purpose. Certain components of this software are licensed under the GNU General Public License (GPL) version 2.0 or GNU General Public License (GPL) version 3.0 or the GNU Lesser General Public License (LGPL) Version 2.1 or Lesser General Public License (LGPL) Version 2.0. A copy of each such license is available at http://www.opensource.org/licenses/gpl-2.0.php and http://opensource.org/licenses/gpl-3.0.html and http://www.opensource.org/licenses/lgpl-2.1.php and http://www.gnu.org/licenses/old-licenses/library.txt. Software BIOS: version 07.57 NXOS: version 7.0(3)I5(1) [build 7.0(3)I5(0.9)] BIOS compile time: 06/29/2016 NXOS image file is: bootflash:///nxos.7.0.3.I5.0.9.bin NXOS compile time: 8/1/2016 23:00:00 [08/02/2016 00:30:32] . . .", "title": "Vulnerable Products" }, { "category": "general", "text": "Only products listed in the Vulnerable Products [\"#vp\"] section of this advisory are known to be affected by this vulnerability.\r\n\r\nCisco has confirmed that this vulnerability does not affect the following Cisco products:\r\n\r\nFirepower 2100 Series Firewalls\r\nFirepower 4100 Series Next-Generation Firewalls\r\nFirepower 9300 Security Appliance\r\nMDS 9000 Series Multilayer Switches\r\nNexus 1000V Switch for Microsoft Hyper-V\r\nNexus 1000V Switch for VMware vSphere\r\nNexus 2000 Series Fabric Extenders\r\nNexus 5500 Platform Switches\r\nNexus 5600 Platform Switches\r\nNexus 6000 Series Switches\r\nNexus 7000 Series Switches\r\nNexus 7700 Series Switches\r\nNexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode\r\nUCS 6200 Series Fabric Interconnects\r\nUCS 6300 Series Fabric Interconnects\r\nUCS 6400 Series Fabric Interconnects", "title": "Products Confirmed Not Vulnerable" }, { "category": "general", "text": "This bundle contains several similar CLI command injection vulnerabilities; they differ primarily in which products and software versions are affected. This table illustrates the affected products for each vulnerability, identified by the defect ID and the CVE ID used in the security advisory title.\r\n\r\n Security Advisory FP 4100/9300 N3K/N9K N3500 N2K/N5K/N6K MDS/N7K N3600/N9500R Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1606) N/A CSCvh85760 CSCvh85760 N/A N/A N/A Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1607) N/A N/A N/A N/A CSCvi014161 N/A Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1608) N/A N/A N/A N/A CSCvi01422 N/A Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1609) N/A CSCvj63253 CSCvj63253 N/A CSCvk51388 CSCvk51387 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1610) N/A CSCvj619912 CSCvj61991 N/A N/A N/A Cisco NX-OS and FXOS Software CLI Command Injection Vulnerability (CVE-2019-1611) CSCvk65447 CSCvj65666 CSCvj65666 CSCvk65444 CSCvj63798 CSCvk65482 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612) N/A CSCvi42373 CSCvi42373 N/A N/A CSCvj12009 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1613) N/A CSCvj65654 CSCvk50906 N/A CSCvj63807 CSCvk50903 1CSCvi01416 is applicable to only the Nexus 7000 Series Switches. The MDS 9000 Series Multilayer Switches are not affected by this vulnerability.\r\n2CSCvj61991 is applicable to only the Nexus 3000 Series Switches. The Nexus 9000 Series Switches in standalone NX-OS mode are not affected by this vulnerability.", "title": "Details" }, { "category": "general", "text": "There are no workarounds that address this vulnerability.", "title": "Workarounds" }, { "category": "general", "text": "Cisco has released free software updates that address the vulnerability described in this advisory. Customers may only install and expect support for software versions and feature sets for which they have purchased a license. By installing, downloading, accessing, or otherwise using such software upgrades, customers agree to follow the terms of the Cisco software license:\r\nhttps://www.cisco.com/c/en/us/products/end-user-license-agreement.html [\"https://www.cisco.com/c/en/us/products/end-user-license-agreement.html\"]\r\n\r\nAdditionally, customers may only download software for which they have a valid license, procured from Cisco directly, or through a Cisco authorized reseller or partner. In most cases this will be a maintenance upgrade to software that was previously purchased. Free security software updates do not entitle customers to a new software license, additional software feature sets, or major revision upgrades.\r\n\r\nWhen considering software upgrades, customers are advised to regularly consult the advisories for Cisco products, which are available from the Cisco Security Advisories and Alerts page [\"https://www.cisco.com/go/psirt\"], to determine exposure and a complete upgrade solution.\r\n\r\nIn all cases, customers should ensure that the devices to be upgraded contain sufficient memory and confirm that current hardware and software configurations will continue to be supported properly by the new release. If the information is not clear, customers are advised to contact the Cisco Technical Assistance Center (TAC) or their contracted maintenance providers.\r\n Customers Without Service Contracts\r\nCustomers who purchase directly from Cisco but do not hold a Cisco service contract and customers who make purchases through third-party vendors but are unsuccessful in obtaining fixed software through their point of sale should obtain upgrades by contacting the Cisco TAC:\r\nhttps://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html [\"https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html\"]\r\n\r\nCustomers should have the product serial number available and be prepared to provide the URL of this advisory as evidence of entitlement to a free upgrade.\r\n Fixed Releases\r\n\r\nCustomers are advised to upgrade to an appropriate release [\"https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html#fixes\"] as indicated in the applicable table in this section. To help ensure a complete upgrade solution, customers should consider that this advisory is part of a bundled publication. The following page provides a complete list of bundle advisories: Cisco Event Response: March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication [\"https://sec.cloudapps.cisco.com/security/center/viewErp.x?alertId=ERP-70757\"].\r\n\r\nIn the following tables, the left column lists releases of Cisco FXOS Software or Cisco NX-OS Software. The center column indicates whether a release is affected by the vulnerability described in this advisory and the first release that includes the fix for this vulnerability. The right column indicates whether a release is affected by all the vulnerabilities described in this bundle and which release includes fixes for those vulnerabilities.\r\n\r\n\r\n\r\nAlthough the releases listed in the right column of each table include fixes for the vulnerabilities, the fix related to the Cisco NX-OS Software Image Signature Verification Vulnerability [\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-sig-verif\"] requires a BIOS upgrade as part of the software upgrade. Customers who are upgrading the software for any of the following products are advised to refer to this advisory for further details about the BIOS upgrade and affected product IDs and BIOS versions:\r\n\r\nNexus 3000 Series Switches\r\nNexus 9000 Series Fabric Switches in ACI mode\r\nNexus 9000 Series Switches in standalone NX-OS mode\r\nNexus 9500 R-Series Line Cards and Fabric Modules\r\n\r\n Nexus 3000 Series Switches: CSCvi42373 [\"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvi42373\"]\r\n\r\n Cisco NX-OS Software Release First Fixed Release for This Vulnerability First Fixed Release for All Vulnerabilities Described in the Bundle of Advisories Prior to 7.0(3)I4 7.0(3)I4(9) 7.0(3)I7(6)\r\n 7.0(3)I4 7.0(3)I4(9) 7.0(3)I7(6)\r\n 7.0(3)I5 7.0(3)I7(4) 7.0(3)I7(6)\r\n 7.0(3)I6 7.0(3)I7(4) 7.0(3)I7(6)\r\n 7.0(3)I7 7.0(3)I7(4) 7.0(3)I7(6)\r\n 9.2 Not vulnerable 9.2(2)\r\n\r\nNexus 3500 Platform Switches: CSCvi42373 [\"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvi42373\"]\r\n\r\n Cisco NX-OS Software Release First Fixed Release for This Vulnerability First Fixed Release for All Vulnerabilities Described in the Bundle of Advisories Prior to 6.0(2)A8 Not vulnerable 6.0(2)A8(11)\r\n 6.0(2)A8 Not vulnerable 6.0(2)A8(11)\r\n 7.0(3) 7.0(3)I7(4) 7.0(3)I7(6)\r\n 9.2 Not vulnerable 9.2(2)\r\n\r\nNexus 3600 Platform Switches: CSCvj12009 [\"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvj12009\"]\r\n\r\n Cisco NX-OS Software Release First Fixed Release for This Vulnerability First Fixed Release for All Vulnerabilities Described in the Bundle of Advisories 7.0(3)F3 7.0(3)F3(3c)1 7.0(3)F3(5)\r\n 9.2 Not vulnerable 9.2(2)\r\n 1This vulnerability is not fixed in 7.0(3)F3(4) but is fixed in 7.0(3)F3(5).\r\n\r\nNexus 9000 Series Switches in Standalone NX-OS Mode: CSCvi42373 [\"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvi42373\"]\r\n\r\n Cisco NX-OS Software Release First Fixed Release for This Vulnerability First Fixed Release for All Vulnerabilities Described in the Bundle of Advisories Prior to 7.0(3)I4 7.0(3)I4(9) 7.0(3)I4(9)\r\n 7.0(3)I4 7.0(3)I4(9) 7.0(3)I7(6)\r\n 7.0(3)I5 7.0(3)I7(4) 7.0(3)I7(6)\r\n 7.0(3)I6 7.0(3)I7(4) 7.0(3)I7(6)\r\n 7.0(3)I7 7.0(3)I7(4) 7.0(3)I7(6)\r\n 9.2 Not vulnerable 9.2(2)\r\n\r\nNexus 9500 R-Series Line Cards and Fabric Modules: CSCvj12009 [\"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvj12009\"]\r\n\r\n Cisco NX-OS Software Release First Fixed Release for This Vulnerability First Fixed Release for All Vulnerabilities Described in the Bundle of Advisories 7.0(3)F1 7.0(3)F3(3c)1 7.0(3)F3(5)\r\n 7.0(3)F2 7.0(3)F3(3c)1 7.0(3)F3(5)\r\n 7.0(3)F3 7.0(3)F3(3c)1 7.0(3)F3(5)\r\n 9.2 Not vulnerable 9.2(2)\r\n 1This vulnerability is not fixed in 7.0(3)F3(4) but is fixed in 7.0(3)F3(5).\r\nAdditional Resources\r\nFor help determining the best Cisco NX-OS Software release for a Cisco Nexus Switch, administrators can refer to the following Recommended Releases documents. If a security advisory recommends a later release, Cisco recommends following the advisory guidance.\r\n\r\n\r\nCisco MDS Series Switches [\"https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/b_MDS_NX-OS_Recommended_Releases.html\"]\r\nCisco Nexus 1000V for VMware Switch [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/recommended_releases/b_Cisco_N1KV_VMware_MinRecommendedReleases.html\"]\r\nCisco Nexus 3000 Series and 3500 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus3000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_3000_Series_Switches.html\"]\r\nCisco Nexus 5000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/release/recommended_releases/recommended_nx-os_releases.html\"]\r\nCisco Nexus 5500 Platform Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5500/sw/release/recommended_releases/n5500_recommended_nx-os_releases.html\"]\r\nCisco Nexus 6000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus6000/sw/release/recommended_releases/recommended_nx-os_releases.html\"]\r\nCisco Nexus 7000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/recommended_releases/recommended_nx-os_releases.html\"]\r\nCisco Nexus 9000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_9000_Series_Switches.html\"]\r\nCisco Nexus 9000 Series ACI-Mode Switches [\"https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/recommended-release/b_Recommended_Cisco_ACI_Releases.html\"]\r\n For help determining the best Cisco NX-OS Software release for Cisco UCS, refer to the Recommended Releases documents in the release notes for the device.", "title": "Fixed Software" }, { "category": "general", "text": "To learn about Cisco security vulnerability disclosure policies and publications, see the Security Vulnerability Policy [\"https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html\"]. This document also contains instructions for obtaining fixed software and receiving security vulnerability information from Cisco.", "title": "Vulnerability Policy" }, { "category": "general", "text": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.", "title": "Exploitation and Public Announcements" }, { "category": "general", "text": "This vulnerability was found during internal security testing.", "title": "Source" }, { "category": "legal_disclaimer", "text": "THIS DOCUMENT IS PROVIDED ON AN \"AS IS\" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. YOUR USE OF THE INFORMATION ON THE DOCUMENT OR MATERIALS LINKED FROM THE DOCUMENT IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS DOCUMENT AT ANY TIME.\r\n\r\nA standalone copy or paraphrase of the text of this document that omits the distribution URL is an uncontrolled copy and may lack important information or contain factual errors. The information in this document is intended for end users of Cisco products.", "title": "Legal Disclaimer" } ], "publisher": { "category": "vendor", "contact_details": "Emergency Support:\r\n+1 877 228 7302 (toll-free within North America)\r\n+1 408 525 6532 (International direct-dial)\r\nNon-emergency Support:\r\nEmail: psirt@cisco.com\r\nSupport requests that are received via e-mail are typically acknowledged within 48 hours.", "issuing_authority": "Cisco product security incident response is the responsibility of the Cisco Product Security Incident Response Team (PSIRT). The Cisco PSIRT is a dedicated, global team that manages the receipt, investigation, and public reporting of security vulnerability information that is related to Cisco products and networks. The on-call Cisco PSIRT works 24x7 with Cisco customers, independent security researchers, consultants, industry organizations, and other vendors to identify possible security issues with Cisco products and networks.\r\nMore information can be found in Cisco Security Vulnerability Policy available at https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html", "name": "Cisco", "namespace": "https://wwww.cisco.com" }, "references": [ { "category": "self", "summary": "Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "category": "external", "summary": "Cisco Event Response: March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication", "url": "https://sec.cloudapps.cisco.com/security/center/viewErp.x?alertId=ERP-70757" }, { "category": "external", "summary": "Cisco Security Vulnerability Policy", "url": "https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html" }, { "category": "external", "summary": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "category": "external", "summary": "Cisco Event Response: March 2019 Cisco FXOS and NX-OS Software Security Advisory Bundled Publication", "url": "https://sec.cloudapps.cisco.com/security/center/viewErp.x?alertId=ERP-70757" }, { "category": "external", "summary": "https://www.cisco.com/c/en/us/products/end-user-license-agreement.html", "url": "https://www.cisco.com/c/en/us/products/end-user-license-agreement.html" }, { "category": "external", "summary": "Cisco Security Advisories and Alerts page", "url": "https://www.cisco.com/go/psirt" }, { "category": "external", "summary": "https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html", "url": "https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html" }, { "category": "external", "summary": "upgrade to an appropriate release", "url": "https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html#fixes" }, { "category": "external", "summary": "Cisco\u0026nbsp;Event Response: March 2019 Cisco\u0026nbsp;FXOS and NX-OS Software Security Advisory Bundled Publication", "url": "https://sec.cloudapps.cisco.com/security/center/viewErp.x?alertId=ERP-70757" }, { "category": "external", "summary": "Cisco NX-OS Software Image Signature Verification Vulnerability", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-sig-verif" }, { "category": "external", "summary": "CSCvi42373", "url": "https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvi42373" }, { "category": "external", "summary": "CSCvi42373", "url": "https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvi42373" }, { "category": "external", "summary": "CSCvj12009", "url": "https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvj12009" }, { "category": "external", "summary": "CSCvi42373", "url": "https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvi42373" }, { "category": "external", "summary": "CSCvj12009", "url": "https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvj12009" }, { "category": "external", "summary": "Cisco MDS Series Switches", "url": "https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/b_MDS_NX-OS_Recommended_Releases.html" }, { "category": "external", "summary": "Cisco Nexus 1000V for VMware Switch", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/recommended_releases/b_Cisco_N1KV_VMware_MinRecommendedReleases.html" }, { "category": "external", "summary": "Cisco Nexus 3000 Series and 3500 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus3000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_3000_Series_Switches.html" }, { "category": "external", "summary": "Cisco Nexus 5000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/release/recommended_releases/recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 5500 Platform Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5500/sw/release/recommended_releases/n5500_recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 6000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus6000/sw/release/recommended_releases/recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 7000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/recommended_releases/recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 9000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_9000_Series_Switches.html" }, { "category": "external", "summary": "Cisco Nexus 9000 Series ACI-Mode Switches", "url": "https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/recommended-release/b_Recommended_Cisco_ACI_Releases.html" }, { "category": "external", "summary": "Security Vulnerability Policy", "url": "https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html" } ], "title": "Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "tracking": { "current_release_date": "2019-03-06T16:00:00+00:00", "generator": { "date": "2022-09-03T03:17:10+00:00", "engine": { "name": "TVCE" } }, "id": "cisco-sa-20190306-nxos-cmdinj-1612", "initial_release_date": "2019-03-06T16:00:00+00:00", "revision_history": [ { "date": "2019-03-06T15:31:21+00:00", "number": "1.0.0", "summary": "Initial public release." } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "branches": [ { "category": "service_pack", "name": "5.0(3)U1(1)", "product": { "name": "5.0(3)U1(1)", "product_id": "CSAFPID-191391" } }, { "category": "service_pack", "name": "5.0(3)U1(1a)", "product": { "name": "5.0(3)U1(1a)", "product_id": "CSAFPID-191392" } }, { "category": "service_pack", "name": "5.0(3)U1(1b)", "product": { "name": "5.0(3)U1(1b)", "product_id": "CSAFPID-191393" } }, { "category": "service_pack", "name": "5.0(3)U1(1d)", "product": { "name": "5.0(3)U1(1d)", "product_id": "CSAFPID-191466" } }, { "category": "service_pack", "name": "5.0(3)U1(2)", "product": { "name": "5.0(3)U1(2)", "product_id": "CSAFPID-191467" } }, { "category": "service_pack", "name": "5.0(3)U1(2a)", "product": { "name": "5.0(3)U1(2a)", "product_id": "CSAFPID-191468" } }, { "category": "service_pack", "name": "5.0(3)U1(1c)", "product": { "name": "5.0(3)U1(1c)", "product_id": "CSAFPID-239513" } } ], "category": "product_version", "name": "5.0(3)U1" }, { "branches": [ { "category": "service_pack", "name": "5.0(3)U2(1)", "product": { "name": "5.0(3)U2(1)", "product_id": "CSAFPID-191469" } }, { "category": "service_pack", "name": "5.0(3)U2(2)", "product": { "name": "5.0(3)U2(2)", "product_id": "CSAFPID-191470" } }, { "category": "service_pack", "name": "5.0(3)U2(2a)", "product": { "name": "5.0(3)U2(2a)", "product_id": "CSAFPID-191471" } }, { "category": "service_pack", "name": "5.0(3)U2(2b)", "product": { "name": "5.0(3)U2(2b)", "product_id": "CSAFPID-191472" } }, { "category": "service_pack", "name": "5.0(3)U2(2c)", "product": { "name": "5.0(3)U2(2c)", "product_id": "CSAFPID-191473" } }, { "category": "service_pack", "name": "5.0(3)U2(2d)", "product": { "name": "5.0(3)U2(2d)", "product_id": "CSAFPID-191474" } } ], "category": "product_version", "name": "5.0(3)U2" }, { "branches": [ { "category": "service_pack", "name": "5.0(3)U3(1)", "product": { "name": "5.0(3)U3(1)", "product_id": "CSAFPID-191475" } }, { "category": "service_pack", "name": "5.0(3)U3(2)", "product": { "name": "5.0(3)U3(2)", "product_id": "CSAFPID-191476" } }, { "category": "service_pack", "name": "5.0(3)U3(2a)", "product": { "name": "5.0(3)U3(2a)", "product_id": "CSAFPID-191477" } }, { "category": "service_pack", "name": "5.0(3)U3(2b)", "product": { "name": "5.0(3)U3(2b)", "product_id": "CSAFPID-191478" } } ], "category": "product_version", "name": "5.0(3)U3" }, { "branches": [ { "category": "service_pack", "name": "5.0(3)U4(1)", "product": { "name": "5.0(3)U4(1)", "product_id": "CSAFPID-191479" } } ], "category": "product_version", "name": "5.0(3)U4" }, { "branches": [ { "category": "service_pack", "name": "5.0(3)U5(1)", "product": { "name": "5.0(3)U5(1)", "product_id": "CSAFPID-191480" } }, { "category": "service_pack", "name": "5.0(3)U5(1a)", "product": { "name": "5.0(3)U5(1a)", "product_id": "CSAFPID-191481" } }, { "category": "service_pack", "name": "5.0(3)U5(1b)", "product": { "name": "5.0(3)U5(1b)", "product_id": "CSAFPID-191482" } }, { "category": "service_pack", "name": "5.0(3)U5(1c)", "product": { "name": "5.0(3)U5(1c)", "product_id": "CSAFPID-191483" } }, { "category": "service_pack", "name": "5.0(3)U5(1d)", "product": { "name": "5.0(3)U5(1d)", "product_id": "CSAFPID-191484" } }, { "category": "service_pack", "name": "5.0(3)U5(1e)", "product": { "name": "5.0(3)U5(1e)", "product_id": "CSAFPID-191485" } }, { "category": "service_pack", "name": "5.0(3)U5(1f)", "product": { "name": "5.0(3)U5(1f)", "product_id": "CSAFPID-196613" } }, { "category": "service_pack", "name": "5.0(3)U5(1g)", "product": { "name": "5.0(3)U5(1g)", "product_id": "CSAFPID-196614" } }, { "category": "service_pack", "name": "5.0(3)U5(1h)", "product": { "name": "5.0(3)U5(1h)", "product_id": "CSAFPID-196615" } }, { "category": "service_pack", "name": "5.0(3)U5(1i)", "product": { "name": "5.0(3)U5(1i)", "product_id": "CSAFPID-239530" } }, { "category": "service_pack", "name": "5.0(3)U5(1j)", "product": { "name": "5.0(3)U5(1j)", "product_id": "CSAFPID-239531" } } ], "category": "product_version", "name": "5.0(3)U5" }, { "branches": [ { "category": "service_pack", "name": "6.0(2)U1(1)", "product": { "name": "6.0(2)U1(1)", "product_id": "CSAFPID-194693" } }, { "category": "service_pack", "name": "6.0(2)U1(2)", "product": { "name": "6.0(2)U1(2)", "product_id": "CSAFPID-194694" } }, { "category": "service_pack", "name": "6.0(2)U1(1a)", "product": { "name": "6.0(2)U1(1a)", "product_id": "CSAFPID-196616" } }, { "category": "service_pack", "name": "6.0(2)U1(3)", "product": { "name": "6.0(2)U1(3)", "product_id": "CSAFPID-196617" } }, { "category": "service_pack", "name": "6.0(2)U1(4)", "product": { "name": "6.0(2)U1(4)", "product_id": "CSAFPID-205076" } } ], "category": "product_version", "name": "6.0(2)U1" }, { "branches": [ { "category": "service_pack", "name": "6.0(2)U2(1)", "product": { "name": "6.0(2)U2(1)", "product_id": "CSAFPID-205077" } }, { "category": "service_pack", "name": "6.0(2)U2(2)", "product": { "name": "6.0(2)U2(2)", "product_id": "CSAFPID-205078" } }, { "category": "service_pack", "name": "6.0(2)U2(3)", "product": { "name": "6.0(2)U2(3)", "product_id": "CSAFPID-205079" } }, { "category": "service_pack", "name": "6.0(2)U2(4)", "product": { "name": "6.0(2)U2(4)", "product_id": "CSAFPID-205080" } }, { "category": "service_pack", "name": "6.0(2)U2(5)", "product": { "name": "6.0(2)U2(5)", "product_id": "CSAFPID-205081" } }, { "category": "service_pack", "name": "6.0(2)U2(6)", "product": { "name": "6.0(2)U2(6)", "product_id": "CSAFPID-205082" } } ], "category": "product_version", "name": "6.0(2)U2" }, { "branches": [ { "category": "service_pack", "name": "6.0(2)U3(1)", "product": { "name": "6.0(2)U3(1)", "product_id": "CSAFPID-205083" } }, { "category": "service_pack", "name": "6.0(2)U3(2)", "product": { "name": "6.0(2)U3(2)", "product_id": "CSAFPID-205084" } }, { "category": "service_pack", "name": "6.0(2)U3(3)", "product": { "name": "6.0(2)U3(3)", "product_id": "CSAFPID-205085" } }, { "category": "service_pack", "name": "6.0(2)U3(4)", "product": { "name": "6.0(2)U3(4)", "product_id": "CSAFPID-205086" } }, { "category": "service_pack", "name": "6.0(2)U3(5)", "product": { "name": "6.0(2)U3(5)", "product_id": "CSAFPID-205087" } }, { "category": "service_pack", "name": "6.0(2)U3(6)", "product": { "name": "6.0(2)U3(6)", "product_id": "CSAFPID-239536" } }, { "category": "service_pack", "name": "6.0(2)U3(7)", "product": { "name": "6.0(2)U3(7)", "product_id": "CSAFPID-239537" } }, { "category": "service_pack", "name": "6.0(2)U3(8)", "product": { "name": "6.0(2)U3(8)", "product_id": "CSAFPID-239538" } }, { "category": "service_pack", "name": "6.0(2)U3(9)", "product": { "name": "6.0(2)U3(9)", "product_id": "CSAFPID-239539" } } ], "category": "product_version", "name": "6.0(2)U3" }, { "branches": [ { "category": "service_pack", "name": "6.0(2)U4(1)", "product": { "name": "6.0(2)U4(1)", "product_id": "CSAFPID-203349" } }, { "category": "service_pack", "name": "6.0(2)U4(2)", "product": { "name": "6.0(2)U4(2)", "product_id": "CSAFPID-205088" } }, { "category": "service_pack", "name": "6.0(2)U4(3)", "product": { "name": "6.0(2)U4(3)", "product_id": "CSAFPID-205089" } }, { "category": "service_pack", "name": "6.0(2)U4(4)", "product": { "name": "6.0(2)U4(4)", "product_id": "CSAFPID-239545" } } ], "category": "product_version", "name": "6.0(2)U4" }, { "branches": [ { "category": "service_pack", "name": "6.0(2)U5(1)", "product": { "name": "6.0(2)U5(1)", "product_id": "CSAFPID-205090" } }, { "category": "service_pack", "name": "6.0(2)U5(2)", "product": { "name": "6.0(2)U5(2)", "product_id": "CSAFPID-220702" } }, { "category": "service_pack", "name": "6.0(2)U5(3)", "product": { "name": "6.0(2)U5(3)", "product_id": "CSAFPID-220703" } }, { "category": "service_pack", "name": "6.0(2)U5(4)", "product": { "name": "6.0(2)U5(4)", "product_id": "CSAFPID-220704" } } ], "category": "product_version", "name": "6.0(2)U5" }, { "branches": [ { "category": "service_pack", "name": "6.0(2)U6(1)", "product": { "name": "6.0(2)U6(1)", "product_id": "CSAFPID-213569" } }, { "category": "service_pack", "name": "6.0(2)U6(2)", "product": { "name": "6.0(2)U6(2)", "product_id": "CSAFPID-213570" } }, { "category": "service_pack", "name": "6.0(2)U6(3)", "product": { "name": "6.0(2)U6(3)", "product_id": "CSAFPID-213571" } }, { "category": "service_pack", "name": "6.0(2)U6(4)", "product": { "name": "6.0(2)U6(4)", "product_id": "CSAFPID-213572" } }, { "category": "service_pack", "name": "6.0(2)U6(5)", "product": { "name": "6.0(2)U6(5)", "product_id": "CSAFPID-213573" } }, { "category": "service_pack", "name": "6.0(2)U6(6)", "product": { "name": "6.0(2)U6(6)", "product_id": "CSAFPID-220699" } }, { "category": "service_pack", "name": "6.0(2)U6(7)", "product": { "name": "6.0(2)U6(7)", "product_id": "CSAFPID-220700" } }, { "category": "service_pack", "name": "6.0(2)U6(8)", "product": { "name": "6.0(2)U6(8)", "product_id": "CSAFPID-220701" } }, { "category": "service_pack", "name": "6.0(2)U6(1a)", "product": { "name": "6.0(2)U6(1a)", "product_id": "CSAFPID-239546" } }, { "category": "service_pack", "name": "6.0(2)U6(2a)", "product": { "name": "6.0(2)U6(2a)", "product_id": "CSAFPID-239547" } }, { "category": "service_pack", "name": "6.0(2)U6(3a)", "product": { "name": "6.0(2)U6(3a)", "product_id": "CSAFPID-239548" } }, { "category": "service_pack", "name": "6.0(2)U6(4a)", "product": { "name": "6.0(2)U6(4a)", "product_id": "CSAFPID-239549" } }, { "category": "service_pack", "name": "6.0(2)U6(5a)", "product": { "name": "6.0(2)U6(5a)", "product_id": "CSAFPID-239550" } }, { "category": "service_pack", "name": "6.0(2)U6(5b)", "product": { "name": "6.0(2)U6(5b)", "product_id": "CSAFPID-239551" } }, { "category": "service_pack", "name": "6.0(2)U6(5c)", "product": { "name": "6.0(2)U6(5c)", "product_id": "CSAFPID-239552" } }, { "category": "service_pack", "name": "6.0(2)U6(9)", "product": { "name": "6.0(2)U6(9)", "product_id": "CSAFPID-239553" } }, { "category": "service_pack", "name": "6.0(2)U6(10)", "product": { "name": "6.0(2)U6(10)", "product_id": "CSAFPID-239554" } } ], "category": "product_version", "name": "6.0(2)U6" }, { "branches": [ { "category": "service_pack", "name": "6.1(2)I2(2a)", "product": { "name": "6.1(2)I2(2a)", "product_id": "CSAFPID-201606" } }, { "category": "service_pack", "name": "6.1(2)I2(2b)", "product": { "name": "6.1(2)I2(2b)", "product_id": "CSAFPID-202737" } } ], "category": "product_version", "name": "6.1(2)I2" }, { "branches": [ { "category": "service_pack", "name": "6.1(2)I3(1)", "product": { "name": "6.1(2)I3(1)", "product_id": "CSAFPID-205091" } }, { "category": "service_pack", "name": "6.1(2)I3(2)", "product": { "name": "6.1(2)I3(2)", "product_id": "CSAFPID-205092" } }, { "category": "service_pack", "name": "6.1(2)I3(3)", "product": { "name": "6.1(2)I3(3)", "product_id": "CSAFPID-205093" } }, { "category": "service_pack", "name": "6.1(2)I3(3.78)", "product": { "name": "6.1(2)I3(3.78)", "product_id": "CSAFPID-208867" } }, { "category": "service_pack", "name": "6.1(2)I3(4)", "product": { "name": "6.1(2)I3(4)", "product_id": "CSAFPID-210263" } }, { "category": "service_pack", "name": "6.1(2)I3(3a)", "product": { "name": "6.1(2)I3(3a)", "product_id": "CSAFPID-239451" } }, { "category": "service_pack", "name": "6.1(2)I3(4a)", "product": { "name": "6.1(2)I3(4a)", "product_id": "CSAFPID-239452" } }, { "category": "service_pack", "name": "6.1(2)I3(4b)", "product": { "name": "6.1(2)I3(4b)", "product_id": "CSAFPID-239453" } }, { "category": "service_pack", "name": "6.1(2)I3(4c)", "product": { "name": "6.1(2)I3(4c)", "product_id": "CSAFPID-239454" } }, { "category": "service_pack", "name": "6.1(2)I3(4d)", "product": { "name": "6.1(2)I3(4d)", "product_id": "CSAFPID-239455" } }, { "category": "service_pack", "name": "6.1(2)I3(4e)", "product": { "name": "6.1(2)I3(4e)", "product_id": "CSAFPID-239456" } }, { "category": "service_pack", "name": "6.1(2)I3(5)", "product": { "name": "6.1(2)I3(5)", "product_id": "CSAFPID-239457" } }, { "category": "service_pack", "name": "6.1(2)I3(5a)", "product": { "name": "6.1(2)I3(5a)", "product_id": "CSAFPID-239458" } }, { "category": "service_pack", "name": "6.1(2)I3(5b)", "product": { "name": "6.1(2)I3(5b)", "product_id": "CSAFPID-239459" } } ], "category": "product_version", "name": "6.1(2)I3" }, { "branches": [ { "category": "service_pack", "name": "7.0(2)I2(2c)", "product": { "name": "7.0(2)I2(2c)", "product_id": "CSAFPID-239460" } } ], "category": "product_version", "name": "7.0(2)I2" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)F1(1)", "product": { "name": "7.0(3)F1(1)", "product_id": "CSAFPID-239805" } } ], "category": "product_version", "name": "7.0(3)F1" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)F2(1)", "product": { "name": "7.0(3)F2(1)", "product_id": "CSAFPID-239806" } }, { "category": "service_pack", "name": "7.0(3)F2(2)", "product": { "name": "7.0(3)F2(2)", "product_id": "CSAFPID-239807" } } ], "category": "product_version", "name": "7.0(3)F2" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)F3(1)", "product": { "name": "7.0(3)F3(1)", "product_id": "CSAFPID-239632" } }, { "category": "service_pack", "name": "7.0(3)F3(2)", "product": { "name": "7.0(3)F3(2)", "product_id": "CSAFPID-239633" } }, { "category": "service_pack", "name": "7.0(3)F3(3)", "product": { "name": "7.0(3)F3(3)", "product_id": "CSAFPID-239634" } }, { "category": "service_pack", "name": "7.0(3)F3(3a)", "product": { "name": "7.0(3)F3(3a)", "product_id": "CSAFPID-239635" } }, { "category": "service_pack", "name": "7.0(3)F3(4)", "product": { "name": "7.0(3)F3(4)", "product_id": "CSAFPID-239636" } }, { "category": "service_pack", "name": "7.0(3)F3(3b)", "product": { "name": "7.0(3)F3(3b)", "product_id": "CSAFPID-256141" } } ], "category": "product_version", "name": "7.0(3)F3" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I1(1)", "product": { "name": "7.0(3)I1(1)", "product_id": "CSAFPID-208580" } }, { "category": "service_pack", "name": "7.0(3)I1(1a)", "product": { "name": "7.0(3)I1(1a)", "product_id": "CSAFPID-208581" } }, { "category": "service_pack", "name": "7.0(3)I1(1b)", "product": { "name": "7.0(3)I1(1b)", "product_id": "CSAFPID-208582" } }, { "category": "service_pack", "name": "7.0(3)I1(2)", "product": { "name": "7.0(3)I1(2)", "product_id": "CSAFPID-208583" } }, { "category": "service_pack", "name": "7.0(3)I1(3)", "product": { "name": "7.0(3)I1(3)", "product_id": "CSAFPID-220738" } }, { "category": "service_pack", "name": "7.0(3)I1(3a)", "product": { "name": "7.0(3)I1(3a)", "product_id": "CSAFPID-220739" } }, { "category": "service_pack", "name": "7.0(3)I1(3b)", "product": { "name": "7.0(3)I1(3b)", "product_id": "CSAFPID-220740" } } ], "category": "product_version", "name": "7.0(3)I1" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I2(2a)", "product": { "name": "7.0(3)I2(2a)", "product_id": "CSAFPID-220741" } }, { "category": "service_pack", "name": "7.0(3)I2(2b)", "product": { "name": "7.0(3)I2(2b)", "product_id": "CSAFPID-220742" } }, { "category": "service_pack", "name": "7.0(3)I2(2c)", "product": { "name": "7.0(3)I2(2c)", "product_id": "CSAFPID-220743" } }, { "category": "service_pack", "name": "7.0(3)I2(2d)", "product": { "name": "7.0(3)I2(2d)", "product_id": "CSAFPID-220744" } }, { "category": "service_pack", "name": "7.0(3)I2(2e)", "product": { "name": "7.0(3)I2(2e)", "product_id": "CSAFPID-220745" } }, { "category": "service_pack", "name": "7.0(3)I2(3)", "product": { "name": "7.0(3)I2(3)", "product_id": "CSAFPID-220746" } }, { "category": "service_pack", "name": "7.0(3)I2(4)", "product": { "name": "7.0(3)I2(4)", "product_id": "CSAFPID-220747" } }, { "category": "service_pack", "name": "7.0(3)I2(5)", "product": { "name": "7.0(3)I2(5)", "product_id": "CSAFPID-230554" } }, { "category": "service_pack", "name": "7.0(3)I2(1)", "product": { "name": "7.0(3)I2(1)", "product_id": "CSAFPID-230567" } } ], "category": "product_version", "name": "7.0(3)I2" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I3(1)", "product": { "name": "7.0(3)I3(1)", "product_id": "CSAFPID-220748" } } ], "category": "product_version", "name": "7.0(3)I3" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I4(1)", "product": { "name": "7.0(3)I4(1)", "product_id": "CSAFPID-220749" } }, { "category": "service_pack", "name": "7.0(3)I4(2)", "product": { "name": "7.0(3)I4(2)", "product_id": "CSAFPID-220750" } }, { "category": "service_pack", "name": "7.0(3)I4(3)", "product": { "name": "7.0(3)I4(3)", "product_id": "CSAFPID-220751" } }, { "category": "service_pack", "name": "7.0(3)I4(4)", "product": { "name": "7.0(3)I4(4)", "product_id": "CSAFPID-230530" } }, { "category": "service_pack", "name": "7.0(3)I4(5)", "product": { "name": "7.0(3)I4(5)", "product_id": "CSAFPID-230531" } }, { "category": "service_pack", "name": "7.0(3)I4(6)", "product": { "name": "7.0(3)I4(6)", "product_id": "CSAFPID-230532" } }, { "category": "service_pack", "name": "7.0(3)I4(7)", "product": { "name": "7.0(3)I4(7)", "product_id": "CSAFPID-230534" } }, { "category": "service_pack", "name": "7.0(3)I4(8)", "product": { "name": "7.0(3)I4(8)", "product_id": "CSAFPID-239472" } }, { "category": "service_pack", "name": "7.0(3)I4(8a)", "product": { "name": "7.0(3)I4(8a)", "product_id": "CSAFPID-256872" } }, { "category": "service_pack", "name": "7.0(3)I4(8b)", "product": { "name": "7.0(3)I4(8b)", "product_id": "CSAFPID-256873" } }, { "category": "service_pack", "name": "7.0(3)I4(8z)", "product": { "name": "7.0(3)I4(8z)", "product_id": "CSAFPID-256874" } } ], "category": "product_version", "name": "7.0(3)I4" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I5(1)", "product": { "name": "7.0(3)I5(1)", "product_id": "CSAFPID-230535" } }, { "category": "service_pack", "name": "7.0(3)I5(2)", "product": { "name": "7.0(3)I5(2)", "product_id": "CSAFPID-230536" } } ], "category": "product_version", "name": "7.0(3)I5" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I6(1)", "product": { "name": "7.0(3)I6(1)", "product_id": "CSAFPID-230541" } }, { "category": "service_pack", "name": "7.0(3)I6(2)", "product": { "name": "7.0(3)I6(2)", "product_id": "CSAFPID-239476" } } ], "category": "product_version", "name": "7.0(3)I6" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I7(1)", "product": { "name": "7.0(3)I7(1)", "product_id": "CSAFPID-230542" } }, { "category": "service_pack", "name": "7.0(3)I7(2)", "product": { "name": "7.0(3)I7(2)", "product_id": "CSAFPID-239478" } }, { "category": "service_pack", "name": "7.0(3)I7(3)", "product": { "name": "7.0(3)I7(3)", "product_id": "CSAFPID-239479" } } ], "category": "product_version", "name": "7.0(3)I7" } ], "category": "product_family", "name": "Cisco NX-OS Software" } ], "category": "vendor", "name": "Cisco" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-1612", "ids": [ { "system_name": "Cisco Bug ID", "text": "CSCvi42373" }, { "system_name": "Cisco Bug ID", "text": "CSCvj12009" } ], "notes": [ { "category": "other", "text": "Complete.", "title": "Affected Product Comprehensiveness" } ], "product_status": { "known_affected": [ "CSAFPID-191391", "CSAFPID-191392", "CSAFPID-191393", "CSAFPID-191466", "CSAFPID-191467", "CSAFPID-191468", "CSAFPID-191469", "CSAFPID-191470", "CSAFPID-191471", "CSAFPID-191472", "CSAFPID-191473", "CSAFPID-191474", "CSAFPID-191475", "CSAFPID-191476", "CSAFPID-191477", "CSAFPID-191478", "CSAFPID-191479", "CSAFPID-191480", "CSAFPID-191481", "CSAFPID-191482", "CSAFPID-191483", "CSAFPID-191484", "CSAFPID-191485", "CSAFPID-194693", "CSAFPID-194694", "CSAFPID-196613", "CSAFPID-196614", "CSAFPID-196615", "CSAFPID-196616", "CSAFPID-196617", "CSAFPID-201606", "CSAFPID-202737", "CSAFPID-203349", "CSAFPID-205076", "CSAFPID-205077", "CSAFPID-205078", "CSAFPID-205079", "CSAFPID-205080", "CSAFPID-205081", "CSAFPID-205082", "CSAFPID-205083", "CSAFPID-205084", "CSAFPID-205085", "CSAFPID-205086", "CSAFPID-205087", "CSAFPID-205088", "CSAFPID-205089", "CSAFPID-205090", "CSAFPID-205091", "CSAFPID-205092", "CSAFPID-205093", "CSAFPID-208580", "CSAFPID-208581", "CSAFPID-208582", "CSAFPID-208583", "CSAFPID-208867", "CSAFPID-210263", "CSAFPID-213569", "CSAFPID-213570", "CSAFPID-213571", "CSAFPID-213572", "CSAFPID-213573", "CSAFPID-220699", "CSAFPID-220700", "CSAFPID-220701", "CSAFPID-220702", "CSAFPID-220703", "CSAFPID-220704", "CSAFPID-220738", "CSAFPID-220739", "CSAFPID-220740", "CSAFPID-220741", "CSAFPID-220742", "CSAFPID-220743", "CSAFPID-220744", "CSAFPID-220745", "CSAFPID-220746", "CSAFPID-220747", "CSAFPID-220748", "CSAFPID-220749", "CSAFPID-220750", "CSAFPID-220751", "CSAFPID-230530", "CSAFPID-230531", "CSAFPID-230532", "CSAFPID-230534", "CSAFPID-230535", "CSAFPID-230536", "CSAFPID-230541", "CSAFPID-230542", "CSAFPID-230554", "CSAFPID-230567", "CSAFPID-239451", "CSAFPID-239452", "CSAFPID-239453", "CSAFPID-239454", "CSAFPID-239455", "CSAFPID-239456", "CSAFPID-239457", "CSAFPID-239458", "CSAFPID-239459", "CSAFPID-239460", "CSAFPID-239472", "CSAFPID-239476", "CSAFPID-239478", "CSAFPID-239479", "CSAFPID-239513", "CSAFPID-239530", "CSAFPID-239531", "CSAFPID-239536", "CSAFPID-239537", "CSAFPID-239538", "CSAFPID-239539", "CSAFPID-239545", "CSAFPID-239546", "CSAFPID-239547", "CSAFPID-239548", "CSAFPID-239549", "CSAFPID-239550", "CSAFPID-239551", "CSAFPID-239552", "CSAFPID-239553", "CSAFPID-239554", "CSAFPID-239632", "CSAFPID-239633", "CSAFPID-239634", "CSAFPID-239635", "CSAFPID-239636", "CSAFPID-239805", "CSAFPID-239806", "CSAFPID-239807", "CSAFPID-256141", "CSAFPID-256872", "CSAFPID-256873", "CSAFPID-256874" ] }, "release_date": "2019-03-06T16:00:00+00:00", "remediations": [ { "category": "vendor_fix", "details": "Cisco has released software updates that address this vulnerability.", "product_ids": [ "CSAFPID-191391", "CSAFPID-191392", "CSAFPID-191393", "CSAFPID-191466", "CSAFPID-191467", "CSAFPID-191468", "CSAFPID-191469", "CSAFPID-191470", "CSAFPID-191471", "CSAFPID-191472", "CSAFPID-191473", "CSAFPID-191474", "CSAFPID-191475", "CSAFPID-191476", "CSAFPID-191477", "CSAFPID-191478", "CSAFPID-191479", "CSAFPID-191480", "CSAFPID-191481", "CSAFPID-191482", "CSAFPID-191483", "CSAFPID-191484", "CSAFPID-191485", "CSAFPID-194693", "CSAFPID-194694", "CSAFPID-196613", "CSAFPID-196614", "CSAFPID-196615", "CSAFPID-196616", "CSAFPID-196617", "CSAFPID-201606", "CSAFPID-202737", "CSAFPID-203349", "CSAFPID-205076", "CSAFPID-205077", "CSAFPID-205078", "CSAFPID-205079", "CSAFPID-205080", "CSAFPID-205081", "CSAFPID-205082", "CSAFPID-205083", "CSAFPID-205084", "CSAFPID-205085", "CSAFPID-205086", "CSAFPID-205087", "CSAFPID-205088", "CSAFPID-205089", "CSAFPID-205090", "CSAFPID-205091", "CSAFPID-205092", "CSAFPID-205093", "CSAFPID-208580", "CSAFPID-208581", "CSAFPID-208582", "CSAFPID-208583", "CSAFPID-208867", "CSAFPID-210263", "CSAFPID-213569", "CSAFPID-213570", "CSAFPID-213571", "CSAFPID-213572", "CSAFPID-213573", "CSAFPID-220699", "CSAFPID-220700", "CSAFPID-220701", "CSAFPID-220702", "CSAFPID-220703", "CSAFPID-220704", "CSAFPID-220738", "CSAFPID-220739", "CSAFPID-220740", "CSAFPID-220741", "CSAFPID-220742", "CSAFPID-220743", "CSAFPID-220744", "CSAFPID-220745", "CSAFPID-220746", "CSAFPID-220747", "CSAFPID-220748", "CSAFPID-220749", "CSAFPID-220750", "CSAFPID-220751", "CSAFPID-230530", "CSAFPID-230531", "CSAFPID-230532", "CSAFPID-230534", "CSAFPID-230535", "CSAFPID-230536", "CSAFPID-230541", "CSAFPID-230542", "CSAFPID-230554", "CSAFPID-230567", "CSAFPID-239451", "CSAFPID-239452", "CSAFPID-239453", "CSAFPID-239454", "CSAFPID-239455", "CSAFPID-239456", "CSAFPID-239457", "CSAFPID-239458", "CSAFPID-239459", "CSAFPID-239460", "CSAFPID-239472", "CSAFPID-239476", "CSAFPID-239478", "CSAFPID-239479", "CSAFPID-239513", "CSAFPID-239530", "CSAFPID-239531", "CSAFPID-239536", "CSAFPID-239537", "CSAFPID-239538", "CSAFPID-239539", "CSAFPID-239545", "CSAFPID-239546", "CSAFPID-239547", "CSAFPID-239548", "CSAFPID-239549", "CSAFPID-239550", "CSAFPID-239551", "CSAFPID-239552", "CSAFPID-239553", "CSAFPID-239554", "CSAFPID-239632", "CSAFPID-239633", "CSAFPID-239634", "CSAFPID-239635", "CSAFPID-239636", "CSAFPID-239805", "CSAFPID-239806", "CSAFPID-239807", "CSAFPID-256141", "CSAFPID-256872", "CSAFPID-256873", "CSAFPID-256874" ], "url": "https://software.cisco.com" } ], "scores": [ { "cvss_v3": { "baseScore": 4.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-191391", "CSAFPID-191392", "CSAFPID-191393", "CSAFPID-191466", "CSAFPID-191467", "CSAFPID-191468", "CSAFPID-191469", "CSAFPID-191470", "CSAFPID-191471", "CSAFPID-191472", "CSAFPID-191473", "CSAFPID-191474", "CSAFPID-191475", "CSAFPID-191476", "CSAFPID-191477", "CSAFPID-191478", "CSAFPID-191479", "CSAFPID-191480", "CSAFPID-191481", "CSAFPID-191482", "CSAFPID-191483", "CSAFPID-191484", "CSAFPID-191485", "CSAFPID-194693", "CSAFPID-194694", "CSAFPID-196613", "CSAFPID-196614", "CSAFPID-196615", "CSAFPID-196616", "CSAFPID-196617", "CSAFPID-201606", "CSAFPID-202737", "CSAFPID-203349", "CSAFPID-205076", "CSAFPID-205077", "CSAFPID-205078", "CSAFPID-205079", "CSAFPID-205080", "CSAFPID-205081", "CSAFPID-205082", "CSAFPID-205083", "CSAFPID-205084", "CSAFPID-205085", "CSAFPID-205086", "CSAFPID-205087", "CSAFPID-205088", "CSAFPID-205089", "CSAFPID-205090", "CSAFPID-205091", "CSAFPID-205092", "CSAFPID-205093", "CSAFPID-208580", "CSAFPID-208581", "CSAFPID-208582", "CSAFPID-208583", "CSAFPID-208867", "CSAFPID-210263", "CSAFPID-213569", "CSAFPID-213570", "CSAFPID-213571", "CSAFPID-213572", "CSAFPID-213573", "CSAFPID-220699", "CSAFPID-220700", "CSAFPID-220701", "CSAFPID-220702", "CSAFPID-220703", "CSAFPID-220704", "CSAFPID-220738", "CSAFPID-220739", "CSAFPID-220740", "CSAFPID-220741", "CSAFPID-220742", "CSAFPID-220743", "CSAFPID-220744", "CSAFPID-220745", "CSAFPID-220746", "CSAFPID-220747", "CSAFPID-220748", "CSAFPID-220749", "CSAFPID-220750", "CSAFPID-220751", "CSAFPID-230530", "CSAFPID-230531", "CSAFPID-230532", "CSAFPID-230534", "CSAFPID-230535", "CSAFPID-230536", "CSAFPID-230541", "CSAFPID-230542", "CSAFPID-230554", "CSAFPID-230567", "CSAFPID-239451", "CSAFPID-239452", "CSAFPID-239453", "CSAFPID-239454", "CSAFPID-239455", "CSAFPID-239456", "CSAFPID-239457", "CSAFPID-239458", "CSAFPID-239459", "CSAFPID-239460", "CSAFPID-239472", "CSAFPID-239476", "CSAFPID-239478", "CSAFPID-239479", "CSAFPID-239513", "CSAFPID-239530", "CSAFPID-239531", "CSAFPID-239536", "CSAFPID-239537", "CSAFPID-239538", "CSAFPID-239539", "CSAFPID-239545", "CSAFPID-239546", "CSAFPID-239547", "CSAFPID-239548", "CSAFPID-239549", "CSAFPID-239550", "CSAFPID-239551", "CSAFPID-239552", "CSAFPID-239553", "CSAFPID-239554", "CSAFPID-239632", "CSAFPID-239633", "CSAFPID-239634", "CSAFPID-239635", "CSAFPID-239636", "CSAFPID-239805", "CSAFPID-239806", "CSAFPID-239807", "CSAFPID-256141", "CSAFPID-256872", "CSAFPID-256873", "CSAFPID-256874" ] } ], "title": "Cisco NX-OS System Software CLI Command Injection Vulnerability (CVE-2019-xxxx7)" } ] }
ghsa-rcvx-84w9-r9x5
Vulnerability from github
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).
{ "affected": [], "aliases": [ "CVE-2019-1612" ], "database_specific": { "cwe_ids": [ "CWE-78" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-03-11T21:29:00Z", "severity": "HIGH" }, "details": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).", "id": "GHSA-rcvx-84w9-r9x5", "modified": "2022-05-13T01:31:31Z", "published": "2022-05-13T01:31:31Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-1612" }, { "type": "WEB", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/107388" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
gsd-2019-1612
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-1612", "description": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).", "id": "GSD-2019-1612" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-1612" ], "details": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).", "id": "GSD-2019-1612", "modified": "2023-12-13T01:23:52.230151Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-03-06T16:00:00-0800", "ID": "CVE-2019-1612", "STATE": "PUBLIC", "TITLE": "Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Nexus 3000 Series Switches", "version": { "version_data": [ { "affected": "\u003c", "version_value": "7.0(3)I4(9)" }, { "affected": "\u003c", "version_value": "7.0(3)I7(4)" } ] } }, { "product_name": "Nexus 3500 Platform Switches", "version": { "version_data": [ { "affected": "\u003c", "version_value": "7.0(3)I7(4)" } ] } }, { "product_name": "Nexus 3600 Platform Switches", "version": { "version_data": [ { "affected": "\u003c", "version_value": "7.0(3)F3(5)" } ] } }, { "product_name": "Nexus 9000 Series Switches in Standalone NX-OS Mode", "version": { "version_data": [ { "affected": "\u003c", "version_value": "7.0(3)I4(9)" }, { "affected": "\u003c", "version_value": "7.0(3)I7(4)" } ] } }, { "product_name": "Nexus 9500 R-Series Line Cards and Fabric Modules", "version": { "version_data": [ { "affected": "\u003c", "version_value": "7.0(3)F3(5)" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5)." } ] }, "exploit": [ { "lang": "eng", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. " } ], "impact": { "cvss": { "baseScore": "4.2", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L ", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-77" } ] } ] }, "references": { "reference_data": [ { "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "name": "107388", "refsource": "BID", "url": "http://www.securityfocus.com/bid/107388" } ] }, "source": { "advisory": "cisco-sa-20190306-nxos-cmdinj-1612", "defect": [ [ "CSCvi42373", "CSCvj12009" ] ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(6\\)", "versionStartIncluding": "7.0\\(3\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_3500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(6\\)", "versionStartIncluding": "7.0\\(3\\)i5", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_3000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)", "versionStartIncluding": "7.0\\(3\\)f3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_3600:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)", "versionStartIncluding": "7.0\\(3\\)f1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2019-1612" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-78" } ] } ] }, "references": { "reference_data": [ { "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1612)", "refsource": "CISCO", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "name": "107388", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/107388" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.8, "impactScore": 5.9 } }, "lastModifiedDate": "2019-10-09T23:47Z", "publishedDate": "2019-03-11T21:29Z" } } }
var-201903-0545
Vulnerability from variot
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5). Cisco NX-OS The software includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Cisco Nexus 9500 R-Series Line Cards and Fabric Modules are all products of Cisco. Cisco Nexus 9500 R-Series Line Cards and Fabric Modules is a 9500R series line card module. Cisco NX-OS Software is a set of data center-level operating system software used by switches. Cisco NX-OS is prone to a local command-injection vulnerability. This issue is being tracked by Cisco Bug ID CSCvi42373 and CSCvj12009
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201903-0545", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i5" }, { "model": "nx-os", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i7\\(6\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)f3" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)" }, { "model": "nx-os", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)f3\\(5\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)f1" }, { "model": "nx-os", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "nexus series switche", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "3000" }, { "model": "nexus platform switches", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "3500" }, { "model": "nexus r-series line cards and fabric modules", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "9500" }, { "model": "nexus platform switches", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "3600" }, { "model": "nexus series switches in standalone nx-os mode", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "9000" }, { "model": "nx-os", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "9.2" }, { "model": "nx-os 7.0 i7", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 i6", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 i5", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 i4", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 f3", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 f2", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 f1", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "7.0(3)" }, { "model": "nx-os 6.0 a8", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nexus r-series line cards and fabric modules", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "95000" }, { "model": "nexus series switches in standalone nx-os mode", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "90000" }, { "model": "nexus platform switches", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "36000" }, { "model": "nexus platform switches", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "35000" }, { "model": "nexus series switches", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "30000" }, { "model": "nx-os", "scope": "ne", "trust": 0.3, "vendor": "cisco", "version": "9.2(2)" }, { "model": "nx-os 7.0 i7", "scope": "ne", "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 i4", "scope": "ne", "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 7.0 f3", "scope": "ne", "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os 6.0 a8", "scope": "ne", "trust": 0.3, "vendor": "cisco", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "BID", "id": "107388" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "NVD", "id": "CVE-2019-1612" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(6\\)", "versionStartIncluding": "7.0\\(3\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_3500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(6\\)", "versionStartIncluding": "7.0\\(3\\)i5", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_3000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)", "versionStartIncluding": "7.0\\(3\\)f3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_3600:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)", "versionStartIncluding": "7.0\\(3\\)f1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-1612" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.,vendor ?? ??", "sources": [ { "db": "CNNVD", "id": "CNNVD-201903-149" } ], "trust": 0.6 }, "cve": "CVE-2019-1612", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2019-1612", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2020-47610", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "VHN-148234", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ykramarz@cisco.com", "availabilityImpact": "LOW", "baseScore": 4.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 0.8, "impactScore": 3.4, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-1612", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-1612", "trust": 1.8, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2019-1612", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2020-47610", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201903-149", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-148234", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "VULHUB", "id": "VHN-148234" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "NVD", "id": "CVE-2019-1612" }, { "db": "NVD", "id": "CVE-2019-1612" }, { "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5). Cisco NX-OS The software includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Cisco Nexus 9500 R-Series Line Cards and Fabric Modules are all products of Cisco. Cisco Nexus 9500 R-Series Line Cards and Fabric Modules is a 9500R series line card module. Cisco NX-OS Software is a set of data center-level operating system software used by switches. Cisco NX-OS is prone to a local command-injection vulnerability. \nThis issue is being tracked by Cisco Bug ID CSCvi42373 and CSCvj12009", "sources": [ { "db": "NVD", "id": "CVE-2019-1612" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "BID", "id": "107388" }, { "db": "VULHUB", "id": "VHN-148234" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-1612", "trust": 3.4 }, { "db": "BID", "id": "107388", "trust": 1.4 }, { "db": "JVNDB", "id": "JVNDB-2019-002427", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201903-149", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2020-47610", "trust": 0.6 }, { "db": "NSFOCUS", "id": "42884", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.0699.2", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-148234", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "VULHUB", "id": "VHN-148234" }, { "db": "BID", "id": "107388" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "NVD", "id": "CVE-2019-1612" }, { "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "id": "VAR-201903-0545", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "VULHUB", "id": "VHN-148234" } ], "trust": 1.246026272 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" } ] }, "last_update_date": "2023-12-18T12:00:27.341000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20190306-nxos-cmdinj-1612", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "title": "Patch for Cisco NX-OS Software CLI command injection vulnerability (CNVD-2020-47610)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/231481" }, { "title": "Cisco NX-OS Software Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=89829" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-148234" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "NVD", "id": "CVE-2019-1612" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190306-nxos-cmdinj-1612" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-1612" }, { "trust": 1.1, "url": "http://www.securityfocus.com/bid/107388" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-1612" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/76574" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/42884" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/cisco-nx-os-nexus-multiple-vulnerabilities-28681" }, { "trust": 0.3, "url": "http://www.cisco.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "VULHUB", "id": "VHN-148234" }, { "db": "BID", "id": "107388" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "NVD", "id": "CVE-2019-1612" }, { "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-47610" }, { "db": "VULHUB", "id": "VHN-148234" }, { "db": "BID", "id": "107388" }, { "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "db": "NVD", "id": "CVE-2019-1612" }, { "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-24T00:00:00", "db": "CNVD", "id": "CNVD-2020-47610" }, { "date": "2019-03-11T00:00:00", "db": "VULHUB", "id": "VHN-148234" }, { "date": "2019-03-06T00:00:00", "db": "BID", "id": "107388" }, { "date": "2019-04-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "date": "2019-03-11T21:29:00.793000", "db": "NVD", "id": "CVE-2019-1612" }, { "date": "2019-03-06T00:00:00", "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-24T00:00:00", "db": "CNVD", "id": "CNVD-2020-47610" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-148234" }, { "date": "2019-03-06T00:00:00", "db": "BID", "id": "107388" }, { "date": "2019-04-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-002427" }, { "date": "2019-10-09T23:47:29.797000", "db": "NVD", "id": "CVE-2019-1612" }, { "date": "2019-03-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201903-149" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "BID", "id": "107388" }, { "db": "CNNVD", "id": "CNNVD-201903-149" } ], "trust": 0.9 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco NX-OS In software OS Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-002427" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-201903-149" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.