CVE-2020-7548 (GCVE-0-2020-7548)

Vulnerability from cvelistv5 – Published: 2020-12-01 14:45 – Updated: 2024-08-04 09:33
VLAI
Summary
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.
Severity
No CVSS data available.
CWE
  • CWE-330 - - Use of Insufficiently Random Values
Assigner
References
Impacted products
Vendor Product Version
n/a Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) Affected: Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330 - Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:45:23.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7548",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-330 - Use of Insufficiently Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7548",
    "datePublished": "2020-12-01T14:45:23.000Z",
    "dateReserved": "2020-01-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:33:19.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-7548",
      "date": "2026-05-28",
      "epss": "0.00591",
      "percentile": "0.69519"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:acti9_smartlink_si_d_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"002.004.002\", \"matchCriteriaId\": \"53A4A356-8F64-4D1C-8CCB-28803D59BB5B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:acti9_smartlink_si_d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B2CA2A7D-C3AB-49BE-B4B8-61177D64B2C8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:acti9_smartlink_si_b_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"002.004.002\", \"matchCriteriaId\": \"B72CD29E-2E3E-4E96-A614-355AC1BF348B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:acti9_smartlink_si_b:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CB18AC59-6752-410B-987F-428D074C9B6A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:acti9_powertag_link_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"001.008.007\", \"matchCriteriaId\": \"ED821AB9-402E-47E0-9ACB-C7E97653AF28\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:acti9_powertag_link:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"572B9253-6A4A-456B-B052-A9FB97578BC8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:acti9_powertag_link_hd_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"001.008.007\", \"matchCriteriaId\": \"9D5E8701-CC1C-423D-BC5F-CB9E586F784A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:acti9_powertag_link_hd:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"383B1CB5-BEE7-4387-9B42-925F9F9CC345\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:acti9_smartlink_el_b_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.2.1\", \"matchCriteriaId\": \"424EBA8F-CCF4-49A2-8128-94C0D40C50AE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:acti9_smartlink_el_b:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1C7D7CC7-F949-4EC4-BCA7-B52CD9FF2524\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:wiser_link_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.5.0\", \"matchCriteriaId\": \"15224AF4-3090-45CA-9149-0A7C00E4F917\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:wiser_link:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"808ED268-575E-49A1-9F0A-C68ADC677A1F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:wiser_energy_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.5.0\", \"matchCriteriaId\": \"89706F01-2369-4941-B0FA-793B8D828023\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:wiser_energy:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"84DAFA0A-0CBF-46B2-BB91-2BD44DF23040\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.\"}, {\"lang\": \"es\", \"value\": \"Una CWE-330: Se presenta una vulnerabilidad uso de Valores Insuficientemente Aleatorios en Gateways Serie Smartlink, PowerTag y Wiser (v\\u00e9ase la notificaci\\u00f3n de seguridad para la informaci\\u00f3n de la versi\\u00f3n) que podr\\u00eda permitir a usuarios no autorizados iniciar sesi\\u00f3n\"}]",
      "id": "CVE-2020-7548",
      "lastModified": "2024-11-21T05:37:21.567",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2020-12-01T15:15:12.720",
      "references": "[{\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-287-03/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-287-03/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-330\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-7548\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-12-01T15:15:12.720\",\"lastModified\":\"2024-11-21T05:37:21.567\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.\"},{\"lang\":\"es\",\"value\":\"Una CWE-330: Se presenta una vulnerabilidad uso de Valores Insuficientemente Aleatorios en Gateways Serie Smartlink, PowerTag y Wiser (v\u00e9ase la notificaci\u00f3n de seguridad para la informaci\u00f3n de la versi\u00f3n) que podr\u00eda permitir a usuarios no autorizados iniciar sesi\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-330\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:acti9_smartlink_si_d_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"002.004.002\",\"matchCriteriaId\":\"53A4A356-8F64-4D1C-8CCB-28803D59BB5B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:acti9_smartlink_si_d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2CA2A7D-C3AB-49BE-B4B8-61177D64B2C8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:acti9_smartlink_si_b_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"002.004.002\",\"matchCriteriaId\":\"B72CD29E-2E3E-4E96-A614-355AC1BF348B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:acti9_smartlink_si_b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB18AC59-6752-410B-987F-428D074C9B6A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:acti9_powertag_link_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"001.008.007\",\"matchCriteriaId\":\"ED821AB9-402E-47E0-9ACB-C7E97653AF28\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:acti9_powertag_link:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"572B9253-6A4A-456B-B052-A9FB97578BC8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:acti9_powertag_link_hd_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"001.008.007\",\"matchCriteriaId\":\"9D5E8701-CC1C-423D-BC5F-CB9E586F784A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:acti9_powertag_link_hd:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"383B1CB5-BEE7-4387-9B42-925F9F9CC345\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:acti9_smartlink_el_b_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.1\",\"matchCriteriaId\":\"424EBA8F-CCF4-49A2-8128-94C0D40C50AE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:acti9_smartlink_el_b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C7D7CC7-F949-4EC4-BCA7-B52CD9FF2524\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:wiser_link_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.5.0\",\"matchCriteriaId\":\"15224AF4-3090-45CA-9149-0A7C00E4F917\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:wiser_link:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"808ED268-575E-49A1-9F0A-C68ADC677A1F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:wiser_energy_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.5.0\",\"matchCriteriaId\":\"89706F01-2369-4941-B0FA-793B8D828023\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:wiser_energy:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84DAFA0A-0CBF-46B2-BB91-2BD44DF23040\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-287-03/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-287-03/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…