A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 19:52 UTC
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Impacted products
Vendor Product Version CPE status
Schneider Electric APC Easy UPS Online Monitoring Software Affected: Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA (custom)
guessed Create a notification for this product.
Schneider Electric APC Easy UPS Online Monitoring Software Affected: (Windows 11, Windows Server 2019, 2022 , < V2.5-GA-01-22261 (custom)
guessed Create a notification for this product.
Schneider Electric Schneider Electric Easy UPS Online Monitoring Software Affected: Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GS (custom)
guessed Create a notification for this product.
Schneider Electric Schneider Electric Easy UPS Online Monitoring Software Affected: Windows 11, Windows Server 2019, 2022 , < V2.5-GS-01-22261 (custom)
guessed Create a notification for this product.
Date Public
2022-12-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:19:05.534Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-42972",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T19:52:18.807602Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:06:37.394Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APC Easy UPS Online Monitoring Software",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V2.5-GA",
              "status": "affected",
              "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "APC Easy UPS Online Monitoring Software",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V2.5-GA-01-22261",
              "status": "affected",
              "version": "(Windows 11, Windows Server 2019, 2022",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Schneider Electric Easy UPS Online Monitoring Software",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V2.5-GS",
              "status": "affected",
              "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Schneider Electric Easy UPS Online Monitoring Software",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V2.5-GS-01-22261",
              "status": "affected",
              "version": "Windows 11, Windows Server 2019, 2022",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-12-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-01T00:00:00.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-42972",
    "datePublished": "2023-02-01T00:00:00.000Z",
    "dateReserved": "2022-10-17T00:00:00.000Z",
    "dateUpdated": "2025-02-05T20:06:37.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-42972",
      "date": "2026-09-17",
      "epss": "0.00177",
      "percentile": "0.07548"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741",
                  "versionEndExcluding": "2.5-ga-01-22320",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                  "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952",
                  "versionEndExcluding": "2.5-gs-01-22320",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                  "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1",
                  "versionEndExcluding": "2.5-ga",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
                  "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                  "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B",
                  "versionEndExcluding": "2.5-gs",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
                  "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                  "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
        }
      ],
      "id": "CVE-2022-42972",
      "lastModified": "2024-11-21T07:25:42.930",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2023-02-01T04:15:09.023",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-732"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "APC Easy UPS Online Monitoring Software",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V2.5-GA",
                    "status": "affected",
                    "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "APC Easy UPS Online Monitoring Software",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V2.5-GA-01-22261",
                    "status": "affected",
                    "version": "(Windows 11, Windows Server 2019, 2022",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "Schneider Electric Easy UPS Online Monitoring Software",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V2.5-GS",
                    "status": "affected",
                    "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "Schneider Electric Easy UPS Online Monitoring Software",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V2.5-GS-01-22261",
                    "status": "affected",
                    "version": "Windows 11, Windows Server 2019, 2022",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cybersecurity@se.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741",
                    "versionEndExcluding": "2.5-ga-01-22320",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                    "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952",
                    "versionEndExcluding": "2.5-gs-01-22320",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                    "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1",
                    "versionEndExcluding": "2.5-ga",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
                    "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                    "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B",
                    "versionEndExcluding": "2.5-gs",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
                    "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
                    "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
          }
        ],
        "id": "CVE-2022-42972",
        "lastModified": "2026-06-17T05:05:41.797",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "cybersecurity@se.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-42972",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T19:52:18.807602Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-02-01T04:15:09.023",
        "references": [
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
          }
        ],
        "sourceIdentifier": "cybersecurity@se.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-732"
              }
            ],
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T13:19:05.534Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-42972",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:52:18.807602Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T19:52:20.364Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "APC Easy UPS Online Monitoring Software",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V2.5-GA",
                  "status": "affected",
                  "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "APC Easy UPS Online Monitoring Software",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V2.5-GA-01-22261",
                  "status": "affected",
                  "version": "(Windows 11, Windows Server 2019, 2022",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Schneider Electric Easy UPS Online Monitoring Software",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V2.5-GS",
                  "status": "affected",
                  "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Schneider Electric Easy UPS Online Monitoring Software",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V2.5-GS-01-22261",
                  "status": "affected",
                  "version": "Windows 11, Windows Server 2019, 2022",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-12-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-01T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-42972",
        "datePublished": "2023-02-01T00:00:00.000Z",
        "dateReserved": "2022-10-17T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:37.394Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…