CVE-2023-4516
Vulnerability from cvelistv5
Published
2023-09-14 08:54
Modified
2024-08-02 07:31
Severity ?
EPSS score ?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update
Service that could allow a local attacker to change update source, potentially leading to remote
code execution when the attacker force an update containing malicious content.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:31:06.157Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "IGSS Update Service (IGSSupdateservice.exe)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "v16.0.0.23211 and prior" } ] } ], "datePublic": "2023-09-12T08:53:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n" } ], "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-14T08:54:53.673Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-4516", "datePublished": "2023-09-14T08:54:53.673Z", "dateReserved": "2023-08-24T10:47:22.919Z", "dateUpdated": "2024-08-02T07:31:06.157Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-4516\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-09-14T09:15:08.610\",\"lastModified\":\"2023-09-20T14:03:29.980\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\\nService that could allow a local attacker to change update source, potentially leading to remote\\ncode execution when the attacker force an update containing malicious content.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad \\\"CWE-306: Autenticaci\u00f3n Faltante para Funciones Cr\u00edticas\\\" en el servicio de actualizaci\u00f3n IGSS que podr\u00eda permitir a un atacante local cambiar la fuente de actualizaci\u00f3n, lo que podr\u00eda provocar la ejecuci\u00f3n remota de c\u00f3digo cuando el atacante fuerce una actualizaci\u00f3n que contenga contenido malicioso.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.0.0.23211\",\"matchCriteriaId\":\"93B0387C-D40E-446F-AD55-4214804A0B4D\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.