CVE-2025-40774 (GCVE-0-2025-40774)
Vulnerability from cvelistv5 – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:03- CWE-257 - Storing Passwords in a Recoverable Format
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | SiPass integrated |
Affected:
0 , < V3.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40774",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:00:56.197262Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:03:05.943Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiPass integrated (All versions \u003c V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.\r\n\r\nSuccessful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-257",
"description": "CWE-257: Storing Passwords in a Recoverable Format",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:21.139Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-599451.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40774",
"datePublished": "2025-10-14T09:15:21.139Z",
"dateReserved": "2025-04-16T08:39:30.033Z",
"dateUpdated": "2025-10-14T19:03:05.943Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-40774\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-10-14T10:15:38.850\",\"lastModified\":\"2025-10-16T14:09:09.060\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SiPass integrated (All versions \u003c V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.\\r\\n\\r\\nSuccessful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-257\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sipass_integrated:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.00\",\"matchCriteriaId\":\"B14D3EF7-F7F6-4B14-BBB0-B5A04AB81C38\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-599451.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-40774\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-14T19:00:56.197262Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-14T19:01:02.807Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 4.4, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SiPass integrated\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-599451.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SiPass integrated (All versions \u003c V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.\\r\\n\\r\\nSuccessful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-257\", \"description\": \"CWE-257: Storing Passwords in a Recoverable Format\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-10-14T09:15:21.139Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-40774\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-14T19:03:05.943Z\", \"dateReserved\": \"2025-04-16T08:39:30.033Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2025-10-14T09:15:21.139Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
GHSA-P3W8-3XP5-28CV
Vulnerability from github – Published: 2025-10-14 12:31 – Updated: 2025-10-14 12:31A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.
Successful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.
{
"affected": [],
"aliases": [
"CVE-2025-40774"
],
"database_specific": {
"cwe_ids": [
"CWE-257"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-10-14T10:15:38Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in SiPass integrated (All versions \u003c V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.\n\nSuccessful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.",
"id": "GHSA-p3w8-3xp5-28cv",
"modified": "2025-10-14T12:31:31Z",
"published": "2025-10-14T12:31:31Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-40774"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-599451.html"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
FKIE_CVE-2025-40774
Vulnerability from fkie_nvd - Published: 2025-10-14 10:15 - Updated: 2025-10-16 14:09| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-599451.html | Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | sipass_integrated | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sipass_integrated:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B14D3EF7-F7F6-4B14-BBB0-B5A04AB81C38",
"versionEndExcluding": "3.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiPass integrated (All versions \u003c V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.\r\n\r\nSuccessful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise."
}
],
"id": "CVE-2025-40774",
"lastModified": "2025-10-16T14:09:09.060",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 3.6,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2025-10-14T10:15:38.850",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-599451.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-257"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
NCSC-2025-0309
Vulnerability from csaf_ncscnl - Published: 2025-10-14 11:22 - Updated: 2025-10-14 11:22A heap-based buffer overflow vulnerability in Accusoft ImageGear 20.1 can be exploited via a specially crafted file, leading to arbitrary code execution.
Palo Alto Networks has integrated Chromium security fixes addressing a high-severity type confusion vulnerability in the V8 JavaScript engine of Google Chrome, which allows remote attackers to perform arbitrary read/write operations via crafted HTML pages.
A vulnerability in SINEC NMS versions prior to V4.0 SP1 allows low privileged authenticated attackers to exploit SQL injection via the getTotalAndFilterCounts endpoint, potentially leading to data insertion and privilege escalation.
A vulnerability in TeleControl Server Basic V3.1 enables unauthenticated remote attackers to access user password hashes and execute authenticated database operations.
A vulnerability in SIMATIC and SIPLUS devices (versions < V2.4.24) allows unauthenticated remote attackers to access configuration data due to improper authentication of configuration connections.
A vulnerability in SiPass integrated versions prior to V3.0 allows stored Cross-Site Scripting (XSS) attacks, enabling code injection and user impersonation.
A vulnerability in SiPass integrated versions prior to V3.0 allows attackers to exploit broken access control, potentially manipulating other users' data due to insufficient server-side authorization checks.
CWE-639 - Authorization Bypass Through User-Controlled KeyA vulnerability in SiPass integrated versions prior to V3.0 allows administrative users to access decryption keys for encrypted passwords, posing a risk of unauthorized access.
A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds write when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute arbitrary code.
A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds write when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute arbitrary code.
A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds read when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute code.
A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds read when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute code.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Siemens heeft kwetsbaarheden verholpen in diverse producten als SIMATIC, SINEC, SIPLUS en Solid Edge.",
"title": "Feiten"
},
{
"category": "description",
"text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- Omzeilen van een beveiligingsmaatregel\n- Omzeilen van authenticatie\n- (Remote) code execution (root/admin rechten)\n- Toegang tot systeemgegevens\n- Verhogen van rechten\n- Spoofing\n\nDe kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "high",
"title": "Schade"
},
{
"category": "general",
"text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"title": "CWE-79"
},
{
"category": "general",
"text": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"title": "CWE-89"
},
{
"category": "general",
"text": "Improper Restriction of Operations within the Bounds of a Memory Buffer",
"title": "CWE-119"
},
{
"category": "general",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "general",
"text": "Storing Passwords in a Recoverable Format",
"title": "CWE-257"
},
{
"category": "general",
"text": "Missing Authentication for Critical Function",
"title": "CWE-306"
},
{
"category": "general",
"text": "Authorization Bypass Through User-Controlled Key",
"title": "CWE-639"
},
{
"category": "general",
"text": "Out-of-bounds Write",
"title": "CWE-787"
},
{
"category": "general",
"text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"title": "CWE-843"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-062309.pdf"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-318832.pdf"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365200.pdf"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-486936.pdf"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-541582.pdf"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599451.pdf"
}
],
"title": "Kwetsbaarheden verholpen in Siemens producten",
"tracking": {
"current_release_date": "2025-10-14T11:22:10.254089Z",
"generator": {
"date": "2025-08-04T16:30:00Z",
"engine": {
"name": "V.A.",
"version": "1.3"
}
},
"id": "NCSC-2025-0309",
"initial_release_date": "2025-10-14T11:22:10.254089Z",
"revision_history": [
{
"date": "2025-10-14T11:22:10.254089Z",
"number": "1.0.0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-1"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1542SP-1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-2"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1542SP-1 IRC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-3"
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1543SP-1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-4"
}
}
],
"category": "product_name",
"name": "SINEC NMS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-5"
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-6"
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP CP 1543SP-1 ISEC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-7"
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-8"
}
}
],
"category": "product_name",
"name": "SiPass integrated"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-9"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2024"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-10"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2025"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-11"
}
}
],
"category": "product_name",
"name": "TeleControl Server Basic V3.1"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-35002",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "other",
"text": "Improper Restriction of Operations within the Bounds of a Memory Buffer",
"title": "CWE-119"
},
{
"category": "description",
"text": "A heap-based buffer overflow vulnerability in Accusoft ImageGear 20.1 can be exploited via a specially crafted file, leading to arbitrary code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2023-35002 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2023/cve-2023-35002.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2023-35002"
},
{
"cve": "CVE-2025-6554",
"cwe": {
"id": "CWE-843",
"name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
},
"notes": [
{
"category": "other",
"text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"title": "CWE-843"
},
{
"category": "description",
"text": "Palo Alto Networks has integrated Chromium security fixes addressing a high-severity type confusion vulnerability in the V8 JavaScript engine of Google Chrome, which allows remote attackers to perform arbitrary read/write operations via crafted HTML pages.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:A/AU:N/R:U/V:D/RE:M/U:Amber",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-6554 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-6554.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-6554"
},
{
"cve": "CVE-2025-40755",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"title": "CWE-89"
},
{
"category": "description",
"text": "A vulnerability in SINEC NMS versions prior to V4.0 SP1 allows low privileged authenticated attackers to exploit SQL injection via the getTotalAndFilterCounts endpoint, potentially leading to data insertion and privilege escalation.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40755 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40755.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40755"
},
{
"cve": "CVE-2025-40765",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "other",
"text": "Missing Authentication for Critical Function",
"title": "CWE-306"
},
{
"category": "description",
"text": "A vulnerability in TeleControl Server Basic V3.1 enables unauthenticated remote attackers to access user password hashes and execute authenticated database operations.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40765 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40765.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40765"
},
{
"cve": "CVE-2025-40771",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "other",
"text": "Missing Authentication for Critical Function",
"title": "CWE-306"
},
{
"category": "description",
"text": "A vulnerability in SIMATIC and SIPLUS devices (versions \u003c V2.4.24) allows unauthenticated remote attackers to access configuration data due to improper authentication of configuration connections.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40771 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40771.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40771"
},
{
"cve": "CVE-2025-40772",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"title": "CWE-79"
},
{
"category": "description",
"text": "A vulnerability in SiPass integrated versions prior to V3.0 allows stored Cross-Site Scripting (XSS) attacks, enabling code injection and user impersonation.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40772 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40772.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40772"
},
{
"cve": "CVE-2025-40773",
"cwe": {
"id": "CWE-639",
"name": "Authorization Bypass Through User-Controlled Key"
},
"notes": [
{
"category": "other",
"text": "Authorization Bypass Through User-Controlled Key",
"title": "CWE-639"
},
{
"category": "description",
"text": "A vulnerability in SiPass integrated versions prior to V3.0 allows attackers to exploit broken access control, potentially manipulating other users\u0027 data due to insufficient server-side authorization checks.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40773 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40773.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40773"
},
{
"cve": "CVE-2025-40774",
"cwe": {
"id": "CWE-257",
"name": "Storing Passwords in a Recoverable Format"
},
"notes": [
{
"category": "other",
"text": "Storing Passwords in a Recoverable Format",
"title": "CWE-257"
},
{
"category": "description",
"text": "A vulnerability in SiPass integrated versions prior to V3.0 allows administrative users to access decryption keys for encrypted passwords, posing a risk of unauthorized access.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40774 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40774.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40774"
},
{
"cve": "CVE-2025-40809",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Write",
"title": "CWE-787"
},
{
"category": "description",
"text": "A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds write when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute arbitrary code.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40809 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40809.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40809"
},
{
"cve": "CVE-2025-40810",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Write",
"title": "CWE-787"
},
{
"category": "description",
"text": "A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds write when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute arbitrary code.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40810 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40810.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40810"
},
{
"cve": "CVE-2025-40811",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "description",
"text": "A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds read when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute code.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40811 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40811.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40811"
},
{
"cve": "CVE-2025-40812",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "description",
"text": "A vulnerability in Solid Edge SE2024 and SE2025 allows for an out of bounds read when parsing specially crafted PRT files, potentially enabling an attacker to crash the application or execute code.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40812 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40812.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11"
]
}
],
"title": "CVE-2025-40812"
}
]
}
ICSA-25-289-06
Vulnerability from csaf_cisa - Published: 2025-10-14 00:00 - Updated: 2026-02-12 07:00| URL | Category | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"document": {
"acknowledgments": [
{
"names": [
"Thomas Wache",
"Yann Breut"
],
"organization": "Airbus Defence and Space - Cyber Program",
"summary": "reporting to Siemens"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SiPass integrated contains multiple vulnerabilities that could allow an unauthenticated remote attacker to exploit user accounts, manipulate data, impersonate users, or achieve arbitrary code execution on the SiPass integrated server.\n\nSiemens has released a new version for SiPass integrated and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-599451 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Commercial Facilities",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-599451: Multiple Vulnerabilities in SiPass integrated - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-599451.json"
},
{
"category": "self",
"summary": "SSA-599451: Multiple Vulnerabilities in SiPass integrated - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-599451.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-289-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-289-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-289-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-289-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens SiPass Integrated",
"tracking": {
"current_release_date": "2026-02-12T07:00:00.000000Z",
"generator": {
"date": "2026-02-11T23:15:53.910733Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-25-289-06",
"initial_release_date": "2025-10-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2025-10-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2026-02-10T00:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "Added fix version V2.95 IR23 for CVE-2023-35002"
},
{
"date": "2026-02-12T07:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "3",
"summary": "CISA Republication update based on Siemens ProductCERT SSA-599451 advisory"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0",
"product": {
"name": "SiPass integrated",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SiPass integrated"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.95.3.23",
"product": {
"name": "SiPass integrated V2.95",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SiPass integrated V2.95"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-35002",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the pictwread functionality of Accusoft ImageGear 20.1. A specially crafted, malformed file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35002"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.95.3.23 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109827049/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2023-35002"
},
{
"cve": "CVE-2025-40772",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected server applications are vulnerable to stored cross-site scripting (XSS), which allows an attacker to inject malicious code that can be executed by other users when they visit the affected page. Successful exploitation enables an attacker to impersonate other users within the application and steal their session data. This could enable unauthorized access to accounts and potentially lead to privilege escalation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-40772"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/79.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995331/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-40772"
},
{
"cve": "CVE-2025-40773",
"cwe": {
"id": "CWE-639",
"name": "Authorization Bypass Through User-Controlled Key"
},
"notes": [
{
"category": "summary",
"text": "Affected server applications contain a broken access control vulnerability. The authorization mechanisms lack sufficient server-side checks, which allows an attacker to execute specific API requests. Successful exploitation may allow an attacker to manipulate data belonging to other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-40773"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/639.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995331/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-40773"
},
{
"cve": "CVE-2025-40774",
"cwe": {
"id": "CWE-257",
"name": "Storing Passwords in a Recoverable Format"
},
"notes": [
{
"category": "summary",
"text": "Affected server applications store user passwords in an encrypted format in their databases. Decryption keys are accessible to users with administrative privileges, which allows them to recover passwords. Successful exploitation of this vulnerability enables an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-40774"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/257.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995331/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-40774"
}
]
}
SSA-599451
Vulnerability from csaf_siemens - Published: 2025-10-14 00:00 - Updated: 2026-02-10 00:00{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SiPass integrated contains multiple vulnerabilities that could allow an unauthenticated remote attacker to exploit user accounts, manipulate data, impersonate users, or achieve arbitrary code execution on the SiPass integrated server.\n\nSiemens has released a new version for SiPass integrated and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-599451: Multiple Vulnerabilities in SiPass integrated - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-599451.html"
},
{
"category": "self",
"summary": "SSA-599451: Multiple Vulnerabilities in SiPass integrated - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-599451.json"
}
],
"title": "SSA-599451: Multiple Vulnerabilities in SiPass integrated",
"tracking": {
"current_release_date": "2026-02-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-599451",
"initial_release_date": "2025-10-14T00:00:00Z",
"revision_history": [
{
"date": "2025-10-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2026-02-10T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix version V2.95 IR23 for CVE-2023-35002"
}
],
"status": "interim",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0",
"product": {
"name": "SiPass integrated",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SiPass integrated"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.95.3.23",
"product": {
"name": "SiPass integrated V2.95",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SiPass integrated V2.95"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-35002",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability exists in the pictwread functionality of Accusoft ImageGear 20.1. A specially crafted malformed file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.95.3.23 or later version",
"product_ids": [
"2"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109827049/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2023-35002"
},
{
"cve": "CVE-2025-40772",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected server applications are vulnerable to stored Cross-Site Scripting (XSS), allowing an attacker to inject malicious code that can be executed by other users when they visit the affected page.\r\n\r\nSuccessful exploitation allows an attacker to impersonate other users within the application and steal their session data. This could enable unauthorized access to accounts and potentially lead to privilege escalation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995331/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40772"
},
{
"cve": "CVE-2025-40773",
"cwe": {
"id": "CWE-639",
"name": "Authorization Bypass Through User-Controlled Key"
},
"notes": [
{
"category": "summary",
"text": "Affected server applications contains a broken access control vulnerability. The authorization mechanism lacks sufficient server-side checks, allowing an attacker to execute a specific API request.\r\n\r\nSuccessful exploitation allows an attacker to potentially manipulate data belonging to other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995331/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40773"
},
{
"cve": "CVE-2025-40774",
"cwe": {
"id": "CWE-257",
"name": "Storing Passwords in a Recoverable Format"
},
"notes": [
{
"category": "summary",
"text": "Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.\r\n\r\nSuccessful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to authorized and trusted personal only",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995331/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40774"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.