CVE-2026-33892 (GCVE-0-2026-33892)
Vulnerability from cvelistv5 – Published: 2026-04-14 08:40 – Updated: 2026-04-14 13:46
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.
This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.
Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.
Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-04-14 13:46 UTC
CWE
- CWE-305 - Authentication Bypass by Primary Weakness
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | Industrial Edge Management Pro V1 |
Affected:
V1.7.6 , < V1.15.17
(custom)
|
guessed | |
| Siemens | Industrial Edge Management Pro V2 |
Affected:
V2.0.0 , < V2.1.1
(custom)
|
guessed | |
| Siemens | Industrial Edge Management Virtual |
Affected:
V2.2.0 , < V2.8.0
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-33892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T13:46:06.348573Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T13:46:34.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Pro V1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.15.17",
"status": "affected",
"version": "V1.7.6",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Pro V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.1.1",
"status": "affected",
"version": "V2.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Virtual",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.8.0",
"status": "affected",
"version": "V2.2.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\r\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\r\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\r\n\r\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305: Authentication Bypass by Primary Weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T08:40:46.807Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-609469.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-33892",
"datePublished": "2026-04-14T08:40:46.807Z",
"dateReserved": "2026-03-24T15:32:19.390Z",
"dateUpdated": "2026-04-14T13:46:34.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-33892",
"date": "2026-10-26",
"epss": "0.00209",
"percentile": "0.10994"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Pro V1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.15.17",
"status": "affected",
"version": "V1.7.6",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Pro V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.1.1",
"status": "affected",
"version": "V2.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Virtual",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.8.0",
"status": "affected",
"version": "V2.2.0",
"versionType": "custom"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\r\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\r\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\r\n\r\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Industrial Edge Management Pro V1 (Todas las versiones \u003e= V1.7.6 anterior a V1.15.17), Industrial Edge Management Pro V2 (Todas las versiones \u003e= V2.0.0 anterior a V2.1.1), Industrial Edge Management Virtual (Todas las versiones \u003e= V2.2.0 anterior a V2.8.0). Los sistemas de gesti\u00f3n afectados no aplican correctamente la autenticaci\u00f3n de usuario en las conexiones remotas a dispositivos.\nEsto podr\u00eda facilitar que un atacante remoto no autenticado eluda la autenticaci\u00f3n e suplante a un usuario leg\u00edtimo.\nLa explotaci\u00f3n exitosa requiere que el atacante haya identificado el encabezado y el puerto utilizados para las conexiones remotas a dispositivos y que la funci\u00f3n de conexi\u00f3n remota est\u00e9 habilitada para el dispositivo. La explotaci\u00f3n permite al atacante tunelizar al dispositivo. Las caracter\u00edsticas de seguridad en este propio dispositivo (por ejemplo, autenticaci\u00f3n espec\u00edfica de la aplicaci\u00f3n) no se ven afectadas."
}
],
"id": "CVE-2026-33892",
"lastModified": "2026-10-24T13:10:00.147",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.7,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-33892",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T13:46:06.348573Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-04-14T09:16:36.097",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-609469.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-305"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-06-05T19:31:30+00:00",
"cve": "CVE-2026-33892",
"id": "CVE-2026-33892",
"initial_release_date": "2026-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2026-33892",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-33892.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-33892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T13:46:06.348573Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T13:46:31.635Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Pro V1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.15.17",
"status": "affected",
"version": "V1.7.6",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Pro V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.1.1",
"status": "affected",
"version": "V2.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Virtual",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.8.0",
"status": "affected",
"version": "V2.2.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\r\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\r\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\r\n\r\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305: Authentication Bypass by Primary Weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T08:40:46.807Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-609469.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-33892",
"datePublished": "2026-04-14T08:40:46.807Z",
"dateReserved": "2026-03-24T15:32:19.390Z",
"dateUpdated": "2026-04-14T13:46:34.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.