CVE-2026-33892 (GCVE-0-2026-33892)

Vulnerability from cvelistv5 – Published: 2026-04-14 08:40 – Updated: 2026-04-14 13:46
VLAI?
Summary
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.
CWE
  • CWE-305 - Authentication Bypass by Primary Weakness
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-33892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T13:46:06.348573Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T13:46:34.636Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Industrial Edge Management Pro V1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.15.17",
              "status": "affected",
              "version": "V1.7.6",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Industrial Edge Management Pro V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.1.1",
              "status": "affected",
              "version": "V2.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Industrial Edge Management Virtual",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.0",
              "status": "affected",
              "version": "V2.2.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\r\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\r\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\r\n\r\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-305",
              "description": "CWE-305: Authentication Bypass by Primary Weakness",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T08:40:46.807Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-609469.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-33892",
    "datePublished": "2026-04-14T08:40:46.807Z",
    "dateReserved": "2026-03-24T15:32:19.390Z",
    "dateUpdated": "2026-04-14T13:46:34.636Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-33892",
      "date": "2026-04-14",
      "epss": "0.00069",
      "percentile": "0.21061"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-33892\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2026-04-14T09:16:36.097\",\"lastModified\":\"2026-04-14T09:16:36.097\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\\r\\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\\r\\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\\r\\n\\r\\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"LOW\",\"subIntegrityImpact\":\"LOW\",\"subAvailabilityImpact\":\"LOW\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.7}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-305\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-609469.html\",\"source\":\"productcert@siemens.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-33892\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-14T13:46:06.348573Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-14T13:46:31.635Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.1, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Industrial Edge Management Pro V1\", \"versions\": [{\"status\": \"affected\", \"version\": \"V1.7.6\", \"lessThan\": \"V1.15.17\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Industrial Edge Management Pro V2\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.0.0\", \"lessThan\": \"V2.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Industrial Edge Management Virtual\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.2.0\", \"lessThan\": \"V2.8.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-609469.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\\r\\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\\r\\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\\r\\n\\r\\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-305\", \"description\": \"CWE-305: Authentication Bypass by Primary Weakness\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2026-04-14T08:40:46.807Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-33892\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-14T13:46:34.636Z\", \"dateReserved\": \"2026-03-24T15:32:19.390Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2026-04-14T08:40:46.807Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…