ICSA-24-165-04
Vulnerability from csaf_cisa
Published
2024-06-11 00:00
Modified
2024-06-11 00:00
Summary
Siemens ST7 ScadaConnect

Notes

Summary
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.



{
  "document": {
    "acknowledgments": [
      {
        "organization": "Siemens ProductCERT",
        "summary": "reporting these vulnerabilities to CISA."
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "other",
        "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
        "title": "Advisory Conversion Disclaimer"
      },
      {
        "category": "other",
        "text": "Multiple",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      }
    ],
    "publisher": {
      "category": "other",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect  before V1.1 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-341067.json"
      },
      {
        "category": "self",
        "summary": "SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect  before V1.1 - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-341067.html"
      },
      {
        "category": "self",
        "summary": "SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect  before V1.1 - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-341067.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect  before V1.1 - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-341067.txt"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-24-165-04 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-165-04.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-24-165-04 - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-04"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      }
    ],
    "title": "Siemens ST7 ScadaConnect",
    "tracking": {
      "current_release_date": "2024-06-11T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1"
        }
      },
      "id": "ICSA-24-165-04",
      "initial_release_date": "2024-06-11T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2024-06-11T00:00:00.000000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV1.1",
                "product": {
                  "name": "ST7 ScadaConnect (6NH7997-5DA10-0AA0)",
                  "product_id": "CSAFPID-0001",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6NH7997-5DA10-0AA0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "ST7 ScadaConnect (6NH7997-5DA10-0AA0)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-40303",
      "cwe": {
        "id": "CWE-190",
        "name": "Integer Overflow or Wraparound"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in libxml2 before 2.10.3. When parsing a multi-gigabyte XML document with the XML_PARSE_HUGE parser option enabled, several integer counters can overflow. This results in an attempt to access an array at a negative 2GB offset, typically leading to a segmentation fault.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2022-40303"
    },
    {
      "cve": "CVE-2022-40304",
      "cwe": {
        "id": "CWE-415",
        "name": "Double Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in libxml2 before 2.10.3. Certain invalid XML entity definitions can corrupt a hash table key, potentially leading to subsequent logic errors. In one case, a double-free can be provoked.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2022-40304"
    },
    {
      "cve": "CVE-2023-0464",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems.\r\n\r\nPolicy processing is disabled by default but can be enabled by passing the `-policy` argument to the command line utilities or by calling the `X509_VERIFY_PARAM_set1_policies()` function.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-0464"
    },
    {
      "cve": "CVE-2023-0465",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Applications that use a non-default option when verifying certificates may be\r\nvulnerable to an attack from a malicious CA to circumvent certain checks.\r\n\r\nInvalid certificate policies in leaf certificates are silently ignored by\r\nOpenSSL and other certificate policy checks are skipped for that certificate.\r\nA malicious CA could use this to deliberately assert invalid certificate policies\r\nin order to circumvent policy checking on the certificate altogether.\r\n\r\nPolicy processing is disabled by default but can be enabled by passing\r\nthe `-policy` argument to the command line utilities or by calling the\r\n`X509_VERIFY_PARAM_set1_policies()` function.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-0465"
    },
    {
      "cve": "CVE-2023-0466",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The function X509_VERIFY_PARAM_add0_policy() is documented to\nimplicitly enable the certificate policy check when doing certificate\nverification. However the implementation of the function does not\nenable the check which allows certificates with invalid or incorrect\npolicies to pass the certificate verification.\n\nAs suddenly enabling the policy check could break existing deployments it was\ndecided to keep the existing behavior of the X509_VERIFY_PARAM_add0_policy()\nfunction.\n\nInstead the applications that require OpenSSL to perform certificate\npolicy check need to use X509_VERIFY_PARAM_set1_policies() or explicitly\nenable the policy check by calling X509_VERIFY_PARAM_set_flags() with\nthe X509_V_FLAG_POLICY_CHECK flag argument.\n\nCertificate policy checks are disabled by default in OpenSSL and are not\ncommonly used by applications.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-0466"
    },
    {
      "cve": "CVE-2023-3446",
      "cwe": {
        "id": "CWE-1333",
        "name": "Inefficient Regular Expression Complexity"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Issue summary: Checking excessively long DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. The function DH_check() performs various checks on DH parameters. One of those checks confirms that the modulus (\u0027p\u0027 parameter) is not too large. Trying to use a very large modulus is slow and OpenSSL will not normally use a modulus which is over 10,000 bits in length. However the DH_check() function checks numerous aspects of the key or parameters that have been supplied. Some of those checks use the supplied modulus value even if it has already been found to be too large. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulernable to a Denial of Service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the \u0027-check\u0027 option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-3446"
    },
    {
      "cve": "CVE-2023-5678",
      "cwe": {
        "id": "CWE-754",
        "name": "Improper Check for Unusual or Exceptional Conditions"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Issue summary: Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn\u0027t make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn\u0027t check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial of Service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the \"-pubcheck\" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-5678"
    },
    {
      "cve": "CVE-2023-21808",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-21808"
    },
    {
      "cve": "CVE-2023-24895",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET, .NET Framework, and Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-24895"
    },
    {
      "cve": "CVE-2023-24897",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET, .NET Framework, and Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-24897"
    },
    {
      "cve": "CVE-2023-24936",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET, .NET Framework, and Visual Studio Elevation of Privilege Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-24936"
    },
    {
      "cve": "CVE-2023-28260",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET DLL Hijacking Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-28260"
    },
    {
      "cve": "CVE-2023-28484",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In libxml2 before 2.10.4, parsing of certain invalid XSD schemas can lead to a NULL pointer dereference and subsequently a segfault. This occurs in xmlSchemaFixupComplexType in xmlschemas.c.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-28484"
    },
    {
      "cve": "CVE-2023-29331",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET, .NET Framework, and Visual Studio Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-29331"
    },
    {
      "cve": "CVE-2023-29469",
      "cwe": {
        "id": "CWE-415",
        "name": "Double Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in libxml2 before 2.10.4. When hashing empty dict strings in a crafted XML document, xmlDictComputeFastKey in dict.c can produce non-deterministic values, leading to various logic and memory errors, such as a double free. This behavior occurs because there is an attempt to use the first byte of an empty string, and any value is possible (not solely the \u0027\\0\u0027 value).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-29469"
    },
    {
      "cve": "CVE-2023-32032",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Elevation of Privilege Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-32032"
    },
    {
      "cve": "CVE-2023-33126",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-33126"
    },
    {
      "cve": "CVE-2023-33127",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Elevation of Privilege Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-33127"
    },
    {
      "cve": "CVE-2023-33128",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-33128"
    },
    {
      "cve": "CVE-2023-33135",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Elevation of Privilege Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-33135"
    },
    {
      "cve": "CVE-2023-33170",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "ASP.NET and Visual Studio Security Feature Bypass Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-33170"
    },
    {
      "cve": "CVE-2023-35390",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-35390"
    },
    {
      "cve": "CVE-2023-35391",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "ASP.NET Core SignalR and Visual Studio Information Disclosure Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-35391"
    },
    {
      "cve": "CVE-2023-36038",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "ASP.NET Core Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36038"
    },
    {
      "cve": "CVE-2023-36049",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET, .NET Framework, and Visual Studio Elevation of Privilege Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36049"
    },
    {
      "cve": "CVE-2023-36435",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Microsoft QUIC Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36435"
    },
    {
      "cve": "CVE-2023-36558",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "ASP.NET Core - Security Feature Bypass Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36558"
    },
    {
      "cve": "CVE-2023-36792",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36792"
    },
    {
      "cve": "CVE-2023-36793",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36793"
    },
    {
      "cve": "CVE-2023-36794",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36794"
    },
    {
      "cve": "CVE-2023-36796",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Visual Studio Remote Code Execution Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36796"
    },
    {
      "cve": "CVE-2023-36799",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET Core and Visual Studio Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-36799"
    },
    {
      "cve": "CVE-2023-38171",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Microsoft QUIC Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-38171"
    },
    {
      "cve": "CVE-2023-38178",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET Core and Visual Studio Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-38178"
    },
    {
      "cve": "CVE-2023-38180",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": ".NET and Visual Studio Denial of Service Vulnerability",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-38180"
    },
    {
      "cve": "CVE-2023-39615",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Xmlsoft Libxml2 v2.11.0 was discovered to contain an out-of-bounds read via the xmlSAX2StartElement() function at /libxml2/SAX2.c. This vulnerability allows attackers to cause a Denial of Service (DoS) via supplying a crafted XML file. NOTE: the vendor\u0027s position is that the product does not support the legacy SAX1 interface with custom callbacks; there is a crash even without crafted input.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-39615"
    },
    {
      "cve": "CVE-2023-44487",
      "cwe": {
        "id": "CWE-400",
        "name": "Uncontrolled Resource Consumption"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109955597/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ],
      "title": "CVE-2023-44487"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.