CVE-2019-1895 (GCVE-0-2019-1895)
Vulnerability from cvelistv5 – Published: 2019-08-07 20:55 – Updated: 2024-11-19 19:02
VLAI?
Summary
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
Severity ?
9.8 (Critical)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cisco | Cisco Enterprise NFV Infrastructure Software |
Affected:
unspecified , < 3.12.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T18:35:52.025Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-1895",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-19T17:21:13.837538Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-19T19:02:07.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Enterprise NFV Infrastructure Software",
"vendor": "Cisco",
"versions": [
{
"lessThan": "3.12.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-07T20:55:11",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass"
}
],
"source": {
"advisory": "cisco-sa-20190807-nfvis-vnc-authbypass",
"defect": [
[
"CSCvm75496",
"CSCvp00281"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-08-07T16:00:00-0700",
"ID": "CVE-2019-1895",
"STATE": "PUBLIC",
"TITLE": "Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Enterprise NFV Infrastructure Software",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "3.12.1"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "9.8",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass"
}
]
},
"source": {
"advisory": "cisco-sa-20190807-nfvis-vnc-authbypass",
"defect": [
[
"CSCvm75496",
"CSCvp00281"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-1895",
"datePublished": "2019-08-07T20:55:11.724228Z",
"dateReserved": "2018-12-06T00:00:00",
"dateUpdated": "2024-11-19T19:02:07.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:enterprise_network_function_virtualization_infrastructure:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.12.1\", \"matchCriteriaId\": \"F45F3AF9-2BE5-452D-AABD-259182A37789\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la implementaci\\u00f3n de la consola de Virtual Network Computing (VNC) de Enterprise NFV Infrastructure Software (NFVIS) de Cisco, podr\\u00eda permitir a un atacante remoto no autenticado acceder a la sesi\\u00f3n de consola VNC de un usuario administrativo en un dispositivo afectado. La vulnerabilidad es debido a un mecanismo de autenticaci\\u00f3n insuficiente utilizado para establecer una sesi\\u00f3n VNC. Un atacante podr\\u00eda explotar esta vulnerabilidad mediante la intercepci\\u00f3n de una petici\\u00f3n de sesi\\u00f3n VNC de administrador antes de iniciar sesi\\u00f3n. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante visualizar la sesi\\u00f3n de la consola del administrador o interactuar con ella, permitiendo el acceso del administrador al dispositivo afectado.\"}]",
"id": "CVE-2019-1895",
"lastModified": "2024-11-21T04:37:38.183",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-08-07T21:15:11.283",
"references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-1895\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2019-08-07T21:15:11.283\",\"lastModified\":\"2024-11-21T04:37:38.183\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la implementaci\u00f3n de la consola de Virtual Network Computing (VNC) de Enterprise NFV Infrastructure Software (NFVIS) de Cisco, podr\u00eda permitir a un atacante remoto no autenticado acceder a la sesi\u00f3n de consola VNC de un usuario administrativo en un dispositivo afectado. La vulnerabilidad es debido a un mecanismo de autenticaci\u00f3n insuficiente utilizado para establecer una sesi\u00f3n VNC. Un atacante podr\u00eda explotar esta vulnerabilidad mediante la intercepci\u00f3n de una petici\u00f3n de sesi\u00f3n VNC de administrador antes de iniciar sesi\u00f3n. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante visualizar la sesi\u00f3n de la consola del administrador o interactuar con ella, permitiendo el acceso del administrador al dispositivo afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:enterprise_network_function_virtualization_infrastructure:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.12.1\",\"matchCriteriaId\":\"F45F3AF9-2BE5-452D-AABD-259182A37789\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\", \"name\": \"20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T18:35:52.025Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2019-1895\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-19T17:21:13.837538Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-19T17:21:48.285Z\"}}], \"cna\": {\"title\": \"Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability\", \"source\": {\"defect\": [[\"CSCvm75496\", \"CSCvp00281\"]], \"advisory\": \"cisco-sa-20190807-nfvis-vnc-authbypass\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"UNCHANGED\", \"version\": \"3.0\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco Enterprise NFV Infrastructure Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"lessThan\": \"3.12.1\", \"versionType\": \"custom\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2019-08-07T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\", \"name\": \"20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2019-08-07T20:55:11\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"9.8\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\"}}, \"source\": {\"defect\": [[\"CSCvm75496\", \"CSCvp00281\"]], \"advisory\": \"cisco-sa-20190807-nfvis-vnc-authbypass\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"affected\": \"\u003c\", \"version_value\": \"3.12.1\", \"version_affected\": \"\u003c\"}]}, \"product_name\": \"Cisco Enterprise NFV Infrastructure Software\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\", \"name\": \"20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-306\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2019-1895\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2019-08-07T16:00:00-0700\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2019-1895\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-19T19:02:07.688Z\", \"dateReserved\": \"2018-12-06T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2019-08-07T20:55:11.724228Z\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…