CVE-2022-34753 (GCVE-0-2022-34753)
Vulnerability from cvelistv5 – Published: 2022-07-13 21:10 – Updated: 2024-09-16 19:14- CWE-78 - OS Command Injection
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_e… | x_refsource_MISC |
| http://packetstormsecurity.com/files/167783/Schne… | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Schneider Electric | SpaceLogic C-Bus Home Controller |
Affected:
5200WHC2 , < V1.31.460
(custom)
|
guessed |
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Characteristics
Timestamps
Scope
Evidence
Type: Honeypot
Signal: In The Wild Attempts
Confidence: 70%
Source: shadowserver
Details
| 1D | 1 |
|---|---|
| Iot | yes |
| Feed | Shadowserver Foundation honeypot/exploited-vulnerabilities |
| Type | http-scan |
| Class | other-software |
| 7D Avg | 1 |
| Vendor | Schneider Electric |
| 30D Avg | 1 |
| 90D Avg | 2 |
| Product | SpaceLogic C-Bus Home Controller (5200WHC2) |
| Cisa Kev | no |
| Connections | 1 |
| Observation Date | 2026-07-19 |
| Vulnerability Class | CVSS |
| Vulnerability Score | 8.8 |
| Vulnerability Severity | High |
References
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Public Report
Signal: Successful Exploitation
Confidence: 70%
Source: kevintel
Details
| Feed | KEVIntel (kevintel.com) |
|---|---|
| Title | A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote... |
| Vendor | Schneider Electric |
| Product | SpaceLogic C-Bus Home Controller |
| Added Date | 2026-06-07T00:00:00.000Z |
| Cvss Score | 8.8 |
| Epss Score | 0.71084 |
| Cvss Severity | HIGH |
| Epss Percentile | 0.99325 |
| Used In Malware | unknown |
| Ahead Of Cisa Kev | None |
| Not Yet In Cisa Kev | True |
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:22:09.210Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SpaceLogic C-Bus Home Controller",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V1.31.460",
"status": "affected",
"version": "5200WHC2",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-07-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-21T21:06:29.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-07-12T11:00:00.000Z",
"ID": "CVE-2022-34753",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceLogic C-Bus Home Controller",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "5200WHC2",
"version_value": "V1.31.460"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf"
},
{
"name": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-34753",
"datePublished": "2022-07-13T21:10:25.007Z",
"dateReserved": "2022-06-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:14:26.516Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-34753",
"date": "2026-09-16",
"epss": "0.71284",
"percentile": "0.99379"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:spacelogic_c-bus_home_controller_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.31.460\", \"matchCriteriaId\": \"D8CF064E-89E7-4371-BD66-F64C938BE0C8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:spacelogic_c-bus_home_controller:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"061CC454-F28A-4836-A757-EB0EBE2B3B0C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)\"}, {\"lang\": \"es\", \"value\": \"Una CWE-78: Se presenta una vulnerabilidad de Neutralizaci\\u00f3n Inapropiada de Elementos Especiales usados en un Comando del Sistema Operativo (\\\"Inyecci\\u00f3n de comandos del SO\\\") que podr\\u00eda causar una explotaci\\u00f3n remota de root cuando el comando est\\u00e1 comprometido. Productos afectados: SpaceLogic C-Bus Home Controller (5200WHC2), anteriormente conocido como C-Bus Wiser Homer Controller MK2 (versiones V1.31.460 y anteriores)\"}]",
"id": "CVE-2022-34753",
"lastModified": "2024-11-21T07:10:07.153",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
"published": "2022-07-13T21:15:08.163",
"references": "[{\"url\": \"http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-34753\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-07-13T21:15:08.163\",\"lastModified\":\"2026-06-17T04:50:51.877\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-78: Se presenta una vulnerabilidad de Neutralizaci\u00f3n Inapropiada de Elementos Especiales usados en un Comando del Sistema Operativo (\\\"Inyecci\u00f3n de comandos del SO\\\") que podr\u00eda causar una explotaci\u00f3n remota de root cuando el comando est\u00e1 comprometido. Productos afectados: SpaceLogic C-Bus Home Controller (5200WHC2), anteriormente conocido como C-Bus Wiser Homer Controller MK2 (versiones V1.31.460 y anteriores)\"}],\"affected\":[{\"source\":\"cybersecurity@se.com\",\"affectedData\":[{\"vendor\":\"Schneider Electric\",\"product\":\"SpaceLogic C-Bus Home Controller\",\"versions\":[{\"version\":\"5200WHC2\",\"lessThan\":\"V1.31.460\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:spacelogic_c-bus_home_controller_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.31.460\",\"matchCriteriaId\":\"D8CF064E-89E7-4371-BD66-F64C938BE0C8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:spacelogic_c-bus_home_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"061CC454-F28A-4836-A757-EB0EBE2B3B0C\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"redhat_vex": {
"current_release_date": "2026-03-27T12:15:03+00:00",
"cve": "CVE-2022-34753",
"id": "CVE-2022-34753",
"initial_release_date": "2022-07-12T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-34753",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-34753.json",
"version": "3"
}
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.