cve-2022-41667
Vulnerability from cvelistv5
Published
2022-11-04 00:00
Modified
2024-08-03 12:49
Severity ?
EPSS score ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
References
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-284-01/ | Patch, Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:49:43.501Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2022-284-01/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Operator Terminal Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "Hotfix 1", "status": "affected", "version": "V3.3", "versionType": "custom" } ] }, { "product": "Pro-face BLUE", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "Hotfix 1", "status": "affected", "version": "V3.3", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior)." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-04T00:00:00", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://www.se.com/ww/en/download/document/SEVD-2022-284-01/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-41667", "datePublished": "2022-11-04T00:00:00", "dateReserved": "2022-09-27T00:00:00", "dateUpdated": "2024-08-03T12:49:43.501Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-41667\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-11-04T12:15:19.153\",\"lastModified\":\"2022-11-05T02:02:42.170\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-22: Limitaci\u00f3n Inadecuada de un Nombre de Ruta a un Directorio Restringido (\\\"Path Traversal\\\") que permite a adversarios con privilegios de usuario local cargar una DLL maliciosa que podr\u00eda conducir a la ejecuci\u00f3n de c\u00f3digo malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.0,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.0,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"5705916B-E189-4314-AD32-C8D42991DFA2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5585436E-9363-4730-9AF5-CE705093E664\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hf1:*:*:*:*:*:*\",\"matchCriteriaId\":\"1495D2CA-263C-4B9F-9C4F-A1DCA574743E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"297C4149-AA1F-4033-BD74-0FB908783399\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:pro-face_blue:3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B593005-BB3F-439A-AF38-F31AFEF6FCB9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hf1:*:*:*:*:*:*\",\"matchCriteriaId\":\"D3D36B2C-AA16-4E42-90AF-DE40D6527D23\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2022-284-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.