CVE-2022-46680 (GCVE-0-2022-46680)
Vulnerability from cvelistv5 – Published: 2023-05-22 13:25 – Updated: 2025-01-21 15:05- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | PowerLogic ION9000 |
Affected:
Prior to 4.0.0
|
|
| Schneider Electric | PowerLogic ION7400 |
Affected:
Prior to 4.0.0
|
|
| Schneider Electric | PowerLogic PM8000 |
Affected:
Prior to 4.0.0
|
|
| Schneider Electric | PowerLogic ION8650 |
Affected:
All Versions
|
|
| Schneider Electric | PowerLogic ION8800 |
Affected:
All Versions
|
|
| Schneider Electric | Legacy ION products |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:39:38.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-21T15:05:13.390998Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-21T15:05:49.099Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION9000",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION7400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": " PowerLogic PM8000",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION8650",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION8800",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy ION products",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2023-05-09T13:18:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-22T13:25:40.615Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-46680",
"datePublished": "2023-05-22T13:25:40.615Z",
"dateReserved": "2022-12-06T21:51:38.755Z",
"dateUpdated": "2025-01-21T15:05:49.099Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-46680",
"date": "2026-05-30",
"epss": "0.00138",
"percentile": "0.33588"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.0.0\", \"matchCriteriaId\": \"50C920E5-0F21-4DBB-9D0E-424F8C1A9B85\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.0.0\", \"matchCriteriaId\": \"E43DFCA4-7ED0-4E61-872A-ECD08659A52B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.0.0\", \"matchCriteriaId\": \"4A560510-3A07-4EBB-8E2D-E473EE9B59C9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7EFB1251-11AE-4A77-AB68-26D6B58C8F33\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"46E8E79E-6DA7-4094-9622-3B91D5913493\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\"}]",
"id": "CVE-2022-46680",
"lastModified": "2024-11-21T07:30:53.443",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2023-05-22T14:15:09.433",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-319\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-46680\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-05-22T14:15:09.433\",\"lastModified\":\"2024-11-21T07:30:53.443\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"50C920E5-0F21-4DBB-9D0E-424F8C1A9B85\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"E43DFCA4-7ED0-4E61-872A-ECD08659A52B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"4A560510-3A07-4EBB-8E2D-E473EE9B59C9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EFB1251-11AE-4A77-AB68-26D6B58C8F33\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46E8E79E-6DA7-4094-9622-3B91D5913493\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:39:38.551Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-46680\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-21T15:05:13.390998Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-21T15:05:31.148Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to 4.0.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION7400\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to 4.0.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \" PowerLogic PM8000\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to 4.0.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION8650\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic ION8800\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Legacy ION products\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-05-09T13:18:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-319\", \"description\": \"CWE-319 Cleartext Transmission of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-05-22T13:25:40.615Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-46680\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-21T15:05:49.099Z\", \"dateReserved\": \"2022-12-06T21:51:38.755Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-05-22T13:25:40.615Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2023-AVI-0363
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer un problème de sécurité non spécifié par l'éditeur, une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | OPC Factory Server (OFS) versions antérieures à V3.63SP2 | ||
| N/A | N/A | Modicon X80 Module (part number BMXNOM0200) versions antérieures à V1.60 | ||
| N/A | N/A | PowerLogic PM8000 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | PowerLogic ION7400 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | EcoStruxure Power Operation versions 2022 antérieures à 2022 CU1 | ||
| N/A | N/A | EcoStruxure Power Operation versions 2021 antérieures à 2021 CU3 | ||
| N/A | N/A | Produits Legacy ION toutes versions | ||
| N/A | N/A | PowerLogic ION9000 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | Power SCADA Anywhere versions 1.1 et 1.2 antérieures à Plant SCADA Anywhere version 2023 | ||
| N/A | N/A | PowerLogic ION8650 toutes versions | ||
| N/A | N/A | Altivar 32/320 et Lexium 32 Ethernet TCP/IP communication module (VW3A3616) versions antérieures à V1.20IE01 | ||
| N/A | N/A | EcoStruxure Power SCADA Operation versions 2020 R2 | ||
| N/A | N/A | PowerLogic ION8800 toutes versions |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "OPC Factory Server (OFS) versions ant\u00e9rieures \u00e0 V3.63SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon X80 Module (part number BMXNOM0200) versions ant\u00e9rieures \u00e0 V1.60",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic PM8000 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION7400 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Operation versions 2022 ant\u00e9rieures \u00e0 2022 CU1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Operation versions 2021 ant\u00e9rieures \u00e0 2021 CU3",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Produits Legacy ION toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION9000 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Power SCADA Anywhere versions 1.1 et 1.2 ant\u00e9rieures \u00e0 Plant SCADA Anywhere version 2023",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION8650 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Altivar 32/320 et Lexium 32 Ethernet TCP/IP communication module (VW3A3616) versions ant\u00e9rieures \u00e0 V1.20IE01",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power SCADA Operation versions 2020 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION8800 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-23854",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23854"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-46680",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46680"
},
{
"name": "CVE-2021-31401",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31401"
},
{
"name": "CVE-2021-3711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3711"
},
{
"name": "CVE-2021-31400",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31400"
},
{
"name": "CVE-2023-1256",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1256"
},
{
"name": "CVE-2020-35685",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35685"
},
{
"name": "CVE-2020-35683",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35683"
},
{
"name": "CVE-2020-35684",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35684"
},
{
"name": "CVE-2020-11022",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11022"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2023-2161",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2161"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0363",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-05-09T00:00:00.000000"
},
{
"description": "Ajout des num\u00e9ros de CVE manquants",
"revision_date": "2023-05-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer un probl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur, une\nex\u00e9cution de code arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-01 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-217-01 du 05 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-217-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-217-01_NicheStack_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-03 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-04 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-02 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
}
]
}
CERTFR-2023-AVI-0363
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer un problème de sécurité non spécifié par l'éditeur, une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | OPC Factory Server (OFS) versions antérieures à V3.63SP2 | ||
| N/A | N/A | Modicon X80 Module (part number BMXNOM0200) versions antérieures à V1.60 | ||
| N/A | N/A | PowerLogic PM8000 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | PowerLogic ION7400 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | EcoStruxure Power Operation versions 2022 antérieures à 2022 CU1 | ||
| N/A | N/A | EcoStruxure Power Operation versions 2021 antérieures à 2021 CU3 | ||
| N/A | N/A | Produits Legacy ION toutes versions | ||
| N/A | N/A | PowerLogic ION9000 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | Power SCADA Anywhere versions 1.1 et 1.2 antérieures à Plant SCADA Anywhere version 2023 | ||
| N/A | N/A | PowerLogic ION8650 toutes versions | ||
| N/A | N/A | Altivar 32/320 et Lexium 32 Ethernet TCP/IP communication module (VW3A3616) versions antérieures à V1.20IE01 | ||
| N/A | N/A | EcoStruxure Power SCADA Operation versions 2020 R2 | ||
| N/A | N/A | PowerLogic ION8800 toutes versions |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "OPC Factory Server (OFS) versions ant\u00e9rieures \u00e0 V3.63SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon X80 Module (part number BMXNOM0200) versions ant\u00e9rieures \u00e0 V1.60",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic PM8000 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION7400 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Operation versions 2022 ant\u00e9rieures \u00e0 2022 CU1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Operation versions 2021 ant\u00e9rieures \u00e0 2021 CU3",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Produits Legacy ION toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION9000 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Power SCADA Anywhere versions 1.1 et 1.2 ant\u00e9rieures \u00e0 Plant SCADA Anywhere version 2023",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION8650 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Altivar 32/320 et Lexium 32 Ethernet TCP/IP communication module (VW3A3616) versions ant\u00e9rieures \u00e0 V1.20IE01",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power SCADA Operation versions 2020 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION8800 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-23854",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23854"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-46680",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46680"
},
{
"name": "CVE-2021-31401",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31401"
},
{
"name": "CVE-2021-3711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3711"
},
{
"name": "CVE-2021-31400",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31400"
},
{
"name": "CVE-2023-1256",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1256"
},
{
"name": "CVE-2020-35685",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35685"
},
{
"name": "CVE-2020-35683",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35683"
},
{
"name": "CVE-2020-35684",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35684"
},
{
"name": "CVE-2020-11022",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11022"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2023-2161",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2161"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0363",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-05-09T00:00:00.000000"
},
{
"description": "Ajout des num\u00e9ros de CVE manquants",
"revision_date": "2023-05-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer un probl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur, une\nex\u00e9cution de code arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-01 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-217-01 du 05 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-217-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-217-01_NicheStack_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-03 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-04 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-02 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
}
]
}
{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (PowerLogic ION8800), \u0434\u043e 4.0.0 (PowerLogic ION9000), \u0434\u043e 4.0.0 (PowerLogic ION7400), \u0434\u043e 4.0.0 (PowerLogic PM8000), - (PowerLogic ION8650)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0443;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0440\u0430\u0437\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0432 \u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u043e\u0439 \u0441\u0440\u0435\u0434\u0435;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0443 \u0438\u0437 \u0432\u043d\u0435\u0448\u043d\u0438\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u0435\u0434\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u0445 USB-\u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN).\n\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\n\u0414\u043b\u044f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432 Schneider Electric:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "09.05.2023",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "28.06.2023",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "28.06.2023",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2023-03465",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-46680",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "PowerLogic ION8800, PowerLogic ION9000, PowerLogic ION7400, PowerLogic PM8000, PowerLogic ION8650",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u0435\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u0447\u0435\u0442\u0447\u0438\u043a\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 Schneider Electric PowerLogic ION9000, PowerLogic ION7400, PowerLogic PM8000, PowerLogic ION8650, PowerLogic ION8800, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435\u0439 \u0434\u0430\u043d\u043d\u044b\u0445 \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u0438\u0434\u0435, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u043c\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u0441\u0435\u043a\u0440\u0435\u0442\u043d\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u0432 \u0432\u0438\u0434\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u0433\u043e \u0442\u0435\u043a\u0441\u0442\u0430 (CWE-319)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u0435\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u0447\u0435\u0442\u0447\u0438\u043a\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 Schneider Electric PowerLogic ION9000, PowerLogic ION7400, PowerLogic PM8000, PowerLogic ION8650, PowerLogic ION8800 \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435\u0439 \u0434\u0430\u043d\u043d\u044b\u0445 \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u0438\u0434\u0435. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u043c\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0441\u0431\u043e\u0440 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-319",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 10)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 8,8)"
}
FKIE_CVE-2022-46680
Vulnerability from fkie_nvd - Published: 2023-05-22 14:15 - Updated: 2024-11-21 07:309.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "50C920E5-0F21-4DBB-9D0E-424F8C1A9B85",
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E43DFCA4-7ED0-4E61-872A-ECD08659A52B",
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4A560510-3A07-4EBB-8E2D-E473EE9B59C9",
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFB1251-11AE-4A77-AB68-26D6B58C8F33",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"id": "CVE-2022-46680",
"lastModified": "2024-11-21T07:30:53.443",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-05-22T14:15:09.433",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-FHXW-QVV7-C595
Vulnerability from github – Published: 2023-05-22 15:30 – Updated: 2024-04-04 04:16A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
{
"affected": [],
"aliases": [
"CVE-2022-46680"
],
"database_specific": {
"cwe_ids": [
"CWE-319"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-05-22T14:15:09Z",
"severity": "CRITICAL"
},
"details": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n",
"id": "GHSA-fhxw-qvv7-c595",
"modified": "2024-04-04T04:16:20Z",
"published": "2023-05-22T15:30:20Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-46680"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2022-46680
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-46680",
"id": "GSD-2022-46680"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-46680"
],
"details": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n",
"id": "GSD-2022-46680",
"modified": "2023-12-13T01:19:37.984484Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-46680",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerLogic ION9000",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Prior to 4.0.0"
}
]
}
},
{
"product_name": "PowerLogic ION7400",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Prior to 4.0.0"
}
]
}
},
{
"product_name": " PowerLogic PM8000",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Prior to 4.0.0"
}
]
}
},
{
"product_name": "PowerLogic ION8650",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "PowerLogic ION8800",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "Legacy ION products",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-319",
"lang": "eng",
"value": "CWE-319 Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-46680"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-05-27T00:54Z",
"publishedDate": "2023-05-22T14:15Z"
}
}
}
ICSA-23-229-03
Vulnerability from csaf_cisa - Published: 2023-08-17 06:00 - Updated: 2023-08-17 06:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
PowerLogic ION9000: < 4.0.0
Schneider Electric / PowerLogic ION9000
|
< 4.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
PowerLogic ION7400: < 4.0.0
Schneider Electric / PowerLogic ION7400
|
< 4.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
PowerLogic PM8000: < 4.0.0
Schneider Electric / PowerLogic PM8000
|
< 4.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
PowerLogic ION8650: *
Schneider Electric / PowerLogic ION8650
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
PowerLogic ION8800: *
Schneider Electric / PowerLogic ION8800
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
Legacy ION products: *
Schneider Electric / Legacy ION products
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
{
"document": {
"acknowledgments": [
{
"names": [
"Jos Wetzels"
],
"organization": "Forescout Technologies",
"summary": "reporting these vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an attacker to cause a disclosure of sensitive information, a denial of service, or modification of data if an attacker is able to intercept network traffic. ",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-23-229-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-229-03.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-23-229-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-229-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 Power Meters",
"tracking": {
"current_release_date": "2023-08-17T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-229-03",
"initial_release_date": "2023-08-17T06:00:00.000000Z",
"revision_history": [
{
"date": "2023-08-17T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 4.0.0",
"product": {
"name": "PowerLogic ION9000: \u003c 4.0.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "PowerLogic ION9000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 4.0.0",
"product": {
"name": "PowerLogic ION7400: \u003c 4.0.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "PowerLogic ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 4.0.0",
"product": {
"name": "PowerLogic PM8000: \u003c 4.0.0",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "PowerLogic PM8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "PowerLogic ION8650: *",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "PowerLogic ION8650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "PowerLogic ION8800: *",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "PowerLogic ION8800"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Legacy ION products: *",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Legacy ION products"
}
],
"category": "vendor",
"name": "Schneider Electric "
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-46680",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "A cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. ",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46680"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released the following remediations for users to implement:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Update affected components to current firmware versions for available vulnerability fixes:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "vendor_fix",
"details": "PowerLogic ION9000: Version 4.0.0 is available for download.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range/64241-powerlogic-ion9000/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "PowerLogic ION7400: Version 4.0.0 is available for download.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "PowerLogic PM8000: Version 4.0.0 is available for download.",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/#software-and-firmware"
},
{
"category": "mitigation",
"details": "Users should use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends using backups and evaluating the impact of these patches in a \"testing and development environment\" or on an offline infrastructure.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Users should contact Schneider Electric for assistance in removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that users ensure devices supporting ION protocol are not exposed to the internet or other untrusted networks. Users should apply the best practices for network hardening as documented in the product user guide and the Schneider Electric Recommended Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "Additional configuration steps and supporting software are required to utilize the secure ION feature. Please refer to the relevant product documentation or contact customer care for additional details and support.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "vendor_fix",
"details": "PowerLogic ION9000: Version 4.0.0 is available for download.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range/64241-powerlogic-ion9000/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "PowerLogic ION7400: Version 4.0.0 is available for download.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "PowerLogic PM8000: Version 4.0.0 is available for download.",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/#software-and-firmware"
},
{
"category": "mitigation",
"details": "Users should use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends using backups and evaluating the impact of these patches in a \"testing and development environment\" or on an offline infrastructure.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Users should contact Schneider Electric for assistance in removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that users ensure devices supporting ION protocol are not exposed to the internet or other untrusted networks. Users should apply the best practices for network hardening as documented in the product user guide and the Schneider Electric Recommended Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "Additional configuration steps and supporting software are required to utilize the secure ION feature. Please refer to the relevant product documentation or contact customer care for additional details and support.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric\u0027s security advisory SEVD-2023-129-03.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends the following industry cybersecurity best practices:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \"Program\" mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
]
}
]
}
SEVD-2023-129-03
Vulnerability from csaf_se - Published: 2023-05-09 16:02 - Updated: 2023-05-09 16:02A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric PowerLogic ION9000 versions prior to 4.0.0
Schneider Electric / PowerLogic ION9000
|
<4.0.0 |
Vendor Fix
fix
|
|
|
Schneider Electric PowerLogic PM8000 versions prior to 4.0.0
Schneider Electric / PowerLogic PM8000
|
<4.0.0 |
Vendor Fix
fix
|
|
|
Schneider Electric PowerLogic ION7400 versions prior to 4.0.0
Schneider Electric / PowerLogic ION7400
|
<4.0.0 |
Vendor Fix
fix
|
|
|
Schneider Electric PowerLogic ION8650 All Versions
Schneider Electric / PowerLogic ION8650
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric PowerLogic ION8800 All Versions
Schneider Electric / PowerLogic ION8800
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Legacy ION products All Versions
Schneider Electric / Legacy ION products
|
vers:all/* |
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric PowerLogic ION9000 version 4.0.0
Schneider Electric / PowerLogic ION9000
|
4.0.0 | ||
|
Schneider Electric PowerLogic ION7400 version 4.0.0
Schneider Electric / PowerLogic ION7400
|
4.0.0 | ||
|
Schneider Electric PowerLogic PM8000 version 4.0.0
Schneider Electric / PowerLogic PM8000
|
4.0.0 |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of the use of an unsecure protocol in its PowerLogic ION9000, \r\nPowerLogic ION7400, PowerLogic PM8000, PowerLogic ION8650, PowerLogic ION8800 and \r\nall legacy ION products. \r\nThe PowerLogic ION9000, PowerLogic ION7400, PowerLogic PM8000, PowerLogic ION8650\r\nand PowerLogic ION8800 are energy and power quality meters. \r\nThis disclosure announces the new secure ION protocol feature for the PowerLogic ION9000, \r\nION7400 and PM8000 products. Secure ION enhances the security of the ION protocol by using\r\na Transport Layer Security (TLS) encrypted tunnel between the device and other systems or \r\nsoftware",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "PowerLogic ION7400 / PM8000 / ION9000 Power Meters - SEVD-2023-129-03 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
},
{
"category": "self",
"summary": "PowerLogic ION7400 / PM8000 / ION9000 Power Meters - SEVD-2023-129-03 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2023-129-03.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "PowerLogic ION7400 / PM8000 / ION9000 Power Meters",
"tracking": {
"current_release_date": "2023-05-09T16:02:26.000Z",
"generator": {
"date": "2023-05-07T16:26:16Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2023-129-03",
"initial_release_date": "2023-05-09T16:02:26.000Z",
"revision_history": [
{
"date": "2023-05-09T16:02:26.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION9000 versions prior to 4.0.0",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "PowerLogic ION9000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.0.0",
"product": {
"name": "Schneider Electric PowerLogic PM8000 versions prior to 4.0.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "PowerLogic PM8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION7400 versions prior to 4.0.0",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "PowerLogic ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric PowerLogic ION8650 All Versions",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "PowerLogic ION8650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric PowerLogic ION8800 All Versions",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "PowerLogic ION8800"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Legacy ION products All Versions",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Legacy ION products"
},
{
"branches": [
{
"category": "product_version",
"name": "4.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION9000 version 4.0.0",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "PowerLogic ION9000"
},
{
"branches": [
{
"category": "product_version",
"name": "4.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION7400 version 4.0.0",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "PowerLogic ION7400"
},
{
"branches": [
{
"category": "product_version",
"name": "4.0.0",
"product": {
"name": "Schneider Electric PowerLogic PM8000 version 4.0.0",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "PowerLogic PM8000"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Jos Wetzels"
],
"organization": "Forescout Technologies"
}
],
"cve": "CVE-2022-46680",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "description",
"text": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 4.0.0 and newer of the PowerLogic ION9000 firmware\r\nincludes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/64241-powerlogic\u0002ion9000/#software-and-firmware \r\nAdditional configuration steps and supporting software are required \r\nto utilize the secure ION feature. Please refer to the relevant product \r\ndocumentation or contact customer care for additional details and \r\nsupport.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/64241-powerlogic-ion9000/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 4.0.0 and newer of the PowerLogic ION7400 firmware includes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/#software-and-firmware\r\nAdditional configuration steps and supporting software are required to utilize the secure ION feature. Please refer to the relevant product documentation or contact customer care for additional details and support.",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 4.0.0 and newer of the PowerLogic PM8000 includes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/#software-and-firmware\r\nAdditional configuration steps and supporting software are required to utilize the secure ION feature. Please refer to the relevant product documentation or contact customer care for additional details and support.",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/#software-and-firmware"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Ensure devices that support ION protocol are not exposed to the Internet or other untrusted networks. Apply the best practices for network hardening documented in product user guide and the Schneider Electric Recommended Cybersecurity Best Practices\r\n\u2022 To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp",
"product_ids": [
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2022-46680"
}
]
}
VAR-202305-2074
Vulnerability from variot - Updated: 2024-06-02 23:03A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. Schneider Electric Provided by the company PowerLogic The product contains the following vulnerabilities: * Plain text transmission of important information (CWE-319) - CVE-2022-46680If the vulnerability is exploited, it may be affected as follows. It was * Sensitive information may be stolen by a remote third party, or service may be disrupted ( DoS ) or have data tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202305-2074",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "powerlogic ion9000",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "4.0.0"
},
{
"model": "powerlogic pm8000",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "4.0.0"
},
{
"model": "powerlogic ion8800",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic ion7400",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "4.0.0"
},
{
"model": "powerlogic ion8650",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": null
},
{
"model": "legacy ion",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic ion7400",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic ion9000",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic pm8000",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic ion8800",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic ion8650",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"cve": "CVE-2022-46680",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cybersecurity@se.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-46680",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-46680",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "cybersecurity@se.com",
"id": "CVE-2022-46680",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202305-1969",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. Schneider Electric Provided by the company PowerLogic The product contains the following vulnerabilities: * Plain text transmission of important information (CWE-319) - CVE-2022-46680If the vulnerability is exploited, it may be affected as follows. It was * Sensitive information may be stolen by a remote third party, or service may be disrupted ( DoS ) or have data tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-46680"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "VULMON",
"id": "CVE-2022-46680"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-46680",
"trust": 3.3
},
{
"db": "SCHNEIDER",
"id": "SEVD-2023-129-03",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-23-229-03",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU93627577",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002903",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1969",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-46680",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-46680"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"id": "VAR-202305-2074",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 1.0
},
"last_update_date": "2024-06-02T23:03:59.712000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Schneider\u00a0Electric\u00a0Security\u00a0Notification\u00a0PowerLogic\u00a0ION7400\u00a0/\u00a0PM8000\u00a0/\u00a0ION9000\u00a0Power\u00a0Meters (( PDF )",
"trust": 0.8,
"url": "https://www.se.com/us/en/download/document/7en52-0390/"
},
{
"title": "Schneider Electric PowerLogic Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=239320"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-319",
"trust": 1.0
},
{
"problemtype": "Sending important information in clear text (CWE-319) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-129-03\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-129-03.pdf"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu93627577/index.html"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-46680"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-229-03"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-46680/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/319.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-46680"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2022-46680"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
},
{
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-22T00:00:00",
"db": "VULMON",
"id": "CVE-2022-46680"
},
{
"date": "2023-08-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"date": "2023-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202305-1969"
},
{
"date": "2023-05-22T14:15:09.433000",
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-22T00:00:00",
"db": "VULMON",
"id": "CVE-2022-46680"
},
{
"date": "2024-05-29T08:48:00",
"db": "JVNDB",
"id": "JVNDB-2023-002903"
},
{
"date": "2023-05-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202305-1969"
},
{
"date": "2023-05-27T00:54:48.257000",
"db": "NVD",
"id": "CVE-2022-46680"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider\u00a0Electric\u00a0 Made \u00a0PowerLogic\u00a0 Vulnerability of Plain Text Transmission of Sensitive Information in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002903"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202305-1969"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.