cve-2022-46680
Vulnerability from cvelistv5
Published
2023-05-22 13:25
Modified
2024-08-03 14:39
Severity ?
EPSS score ?
Summary
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could
cause disclosure of sensitive information, denial of service, or modification of data if an attacker
is able to intercept network traffic.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:39:38.551Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerLogic ION9000", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Prior to 4.0.0" } ] }, { "defaultStatus": "unaffected", "product": "PowerLogic ION7400", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Prior to 4.0.0" } ] }, { "defaultStatus": "unaffected", "product": " PowerLogic PM8000", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Prior to 4.0.0" } ] }, { "defaultStatus": "unaffected", "product": "PowerLogic ION8650", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "PowerLogic ION8800", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "Legacy ION products", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] } ], "datePublic": "2023-05-09T13:18:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n" } ], "value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-22T13:25:40.615Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-46680", "datePublished": "2023-05-22T13:25:40.615Z", "dateReserved": "2022-12-06T21:51:38.755Z", "dateUpdated": "2024-08-03T14:39:38.551Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-46680\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-05-22T14:15:09.433\",\"lastModified\":\"2023-05-27T00:54:48.257\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\\nis able to intercept network traffic. \\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"50C920E5-0F21-4DBB-9D0E-424F8C1A9B85\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"E43DFCA4-7ED0-4E61-872A-ECD08659A52B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.0.0\",\"matchCriteriaId\":\"4A560510-3A07-4EBB-8E2D-E473EE9B59C9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EFB1251-11AE-4A77-AB68-26D6B58C8F33\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46E8E79E-6DA7-4094-9622-3B91D5913493\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.