cve-2023-24555
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:03:19.248Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge SE2022",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V222.0MP12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge SE2023",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V223.0Update2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:31:22.404Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-24555",
    "datePublished": "2023-02-14T10:36:32.550Z",
    "dateReserved": "2023-01-26T14:06:35.400Z",
    "dateUpdated": "2024-08-02T11:03:19.248Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-24555\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-02-14T11:15:15.393\",\"lastModified\":\"2024-02-13T18:02:07.630\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge SE2022 (Todas las versiones \u0026lt; V222.0MP12), Solid Edge SE2023 (Todas las versiones \u0026lt; V223.0Update2). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos PAR especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"22C0D3BE-0640-49C8-86F1-52966CABA2E2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE12CBDF-222E-4DE9-927A-3BDDBFFF1E1A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EEFAAAE5-52B1-48EA-98E1-98A854CBE65A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D5AFCFBB-ED56-4DDB-89D8-B47A20821AB8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"087A9E78-9E5C-4D94-A251-02F9AB160F54\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68EE0588-FE7F-4581-9484-52404DB5B99A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F72318F-0E9C-4AB1-9CA2-6527513AE0F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_8:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63C93992-17F7-4499-BC57-BD67E8A6C508\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7180CEA7-150A-4B1D-BDFD-61C320A33148\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0244EE5-BF22-491A-A7DE-48F44E2A17FC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3A583AAD-5B13-4822-AA24-AA7D16305FE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2210.0002.004\",\"matchCriteriaId\":\"0C855788-002F-41E5-BC01-8597E66EDE1C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...