CVE-2025-13845 (GCVE-0-2025-13845)
Vulnerability from cvelistv5 – Published: 2026-01-15 18:33 – Updated: 2026-01-15 18:54- CWE-416 - Use After Free
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure Power Build Rapsody |
Affected:
FR v2.8.1.0300 and prior
Affected: ESP v2.8.5.0200 and prior Affected: PT v2.8.7.0100 and prior Affected: BEL (FR) v2.8.8.0100 and prior Affected: BEL (EN) v2.8.3.0100 and prior Affected: INT (EN) v2.8.4.0300 and prior Affected: NL v2.8.2.0000 and prior |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13845",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-15T18:52:53.300481Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-15T18:54:16.308Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Build Rapsody",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "FR v2.8.1.0300 and prior"
},
{
"status": "affected",
"version": "ESP v2.8.5.0200 and prior"
},
{
"status": "affected",
"version": "PT v2.8.7.0100 and prior"
},
{
"status": "affected",
"version": "BEL (FR) v2.8.8.0100 and prior"
},
{
"status": "affected",
"version": "BEL (EN) v2.8.3.0100 and prior"
},
{
"status": "affected",
"version": "INT (EN) v2.8.4.0300 and prior"
},
{
"status": "affected",
"version": "NL v2.8.2.0000 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."
}
],
"value": "CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-15T18:33:23.235Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-13845",
"datePublished": "2026-01-15T18:33:23.235Z",
"dateReserved": "2025-12-01T19:20:04.243Z",
"dateUpdated": "2026-01-15T18:54:16.308Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-13845\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2026-01-15T19:16:02.937\",\"lastModified\":\"2026-01-16T15:55:12.257\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-13845\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-15T18:52:53.300481Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-15T18:52:56.978Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.4, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"ACTIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"EcoStruxure Power Build Rapsody\", \"versions\": [{\"status\": \"affected\", \"version\": \"FR v2.8.1.0300 and prior\"}, {\"status\": \"affected\", \"version\": \"ESP v2.8.5.0200 and prior\"}, {\"status\": \"affected\", \"version\": \"PT v2.8.7.0100 and prior\"}, {\"status\": \"affected\", \"version\": \"BEL (FR) v2.8.8.0100 and prior\"}, {\"status\": \"affected\", \"version\": \"BEL (EN) v2.8.3.0100 and prior\"}, {\"status\": \"affected\", \"version\": \"INT (EN) v2.8.4.0300 and prior\"}, {\"status\": \"affected\", \"version\": \"NL v2.8.2.0000 and prior\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-416\", \"description\": \"CWE-416 Use After Free\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2026-01-15T18:33:23.235Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-13845\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-15T18:54:16.308Z\", \"dateReserved\": \"2025-12-01T19:20:04.243Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2026-01-15T18:33:23.235Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
FKIE_CVE-2025-13845
Vulnerability from fkie_nvd - Published: 2026-01-15 19:16 - Updated: 2026-01-16 15:55| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."
},
{
"lang": "es",
"value": "CWE-416: Vulnerabilidad Use After Free que podr\u00eda causar ejecuci\u00f3n remota de c\u00f3digo cuando el usuario final importa el archivo de proyecto malicioso (archivo SSD) en Rapsody."
}
],
"id": "CVE-2025-13845",
"lastModified": "2026-01-16T15:55:12.257",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2026-01-15T19:16:02.937",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Undergoing Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
SEVD-2026-013-04
Vulnerability from csaf_se - Published: 2026-01-13 08:00 - Updated: 2026-03-10 07:00CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CWE-416: Use After Free vulnerability exists that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its EcoStruxure Power Build Rapsody software. The [EcoStruxure Power Build Rapsody](https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309) is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components. \n\nFailure to apply the mitigations/remediations provided below may risk memory corruption, heap-based buffer overflow, stack-based buffer overflow, which could result in local attackers being able to exploit these issues to potentially execute arbitrary code.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u0027s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Multiple Vulnerabilities on EcoStruxure Power Build Rapsody - SEVD-2026-013-04 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
},
{
"category": "self",
"summary": "Multiple Vulnerabilities on EcoStruxure Power Build Rapsody - SEVD-2026-013-04 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2026-013-04.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/ww/en/download/document/7EN52-0390/"
}
],
"title": "Multiple Vulnerabilities on EcoStruxure Power Build Rapsody",
"tracking": {
"current_release_date": "2026-03-10T07:00:00.000Z",
"generator": {
"date": "2026-03-09T19:05:35.339Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2026-013-04",
"initial_release_date": "2026-01-13T08:00:00.000Z",
"revision_history": [
{
"date": "2026-01-13T08:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2026-03-10T07:00:00.000Z",
"number": "2.0.0",
"summary": "Removed the link to the fix for Rapsody Belgium version, which was privately communicated to impacted users"
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.1 FR",
"product": {
"name": "EcoStruxure Power Build Rapsody software FR 2.8.1 and prior",
"product_id": "1"
}
},
{
"category": "product_version",
"name": "2.8.1.0401 FR",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version FR 2.8.1.0401",
"product_id": "2"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.6 INT",
"product": {
"name": "EcoStruxure Power Build Rapsody software INT 2.8.6 and prior",
"product_id": "3"
}
},
{
"category": "product_version",
"name": "2.8.6.200 INT",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version INT 2.8.6.200",
"product_id": "4"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.5 ES",
"product": {
"name": "EcoStruxure Power Build Rapsody software ES 2.8.5 and prior",
"product_id": "5"
}
},
{
"category": "product_version",
"name": "2.8.5.0301 ES",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version ES 2.8.5.0301",
"product_id": "6"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.3 BEL(NL)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(NL) 2.8.3 and prior",
"product_id": "7"
}
},
{
"category": "product_version",
"name": "2.8.3.0201 BEL(NL)",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version BEL(NL) 2.8.3.0201",
"product_id": "8"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.8 BEL(FR)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8 and prior",
"product_id": "9"
}
},
{
"category": "product_version",
"name": "2.8.8.0201 BEL(FR)",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version BEL(FR) 2.8.8.0201",
"product_id": "10"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.1.0300 FR",
"product": {
"name": "EcoStruxure Power Build Rapsody software FR 2.8.1.0300 and prior",
"product_id": "11"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.5.0200 ES",
"product": {
"name": "EcoStruxure Power Build Rapsody software ES 2.8.5.0200 and prior",
"product_id": "12"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.7.0100 PT",
"product": {
"name": "EcoStruxure Power Build Rapsody software PT 2.8.7.0100 and prior",
"product_id": "13"
}
},
{
"category": "product_version",
"name": "2.8.7.0101 PT",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version PT 2.8.7.0101",
"product_id": "14"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.8.0100 BEL(FR)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8.0100 and prior",
"product_id": "15"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.3.0100 BEL(EN)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(EN) 2.8.3.0100 and prior",
"product_id": "16"
}
},
{
"category": "product_version",
"name": "2.8.3.0201 BEL(EN)",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version BEL(EN) 2.8.3.0201",
"product_id": "17"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.4.0300 INT(EN)",
"product": {
"name": "EcoStruxure Power Build Rapsody software INT(EN) 2.8.4.0300 and prior",
"product_id": "18"
}
},
{
"category": "product_version",
"name": "2.8.4.0401 INT(EN)",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version INT(EN) 2.8.4.0401",
"product_id": "19"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.2.0000 NL",
"product": {
"name": "EcoStruxure Power Build Rapsody software NL 2.8.2.0000 and prior",
"product_id": "20"
}
},
{
"category": "product_version",
"name": "2.8.2.000 NL",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version NL 2.8.2.000",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Build Rapsody software"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Michael Heinzl"
]
}
],
"cve": "CVE-2025-13844",
"cwe": {
"id": "CWE-415",
"name": "Double Free"
},
"notes": [
{
"category": "description",
"text": "CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user \r\nimports a malicious project file (SSD file) shared by the attacker into Rapsody.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 4.6 | Medium | [CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L)",
"title": "CVSS 4.0 Score"
}
],
"product_status": {
"fixed": [
"2",
"4",
"6",
"8",
"10"
],
"known_affected": [
"1",
"3",
"5",
"7",
"9"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Versions FR V2.8.1.0401, INT V2.8.6.200, and ES V2.8.5.0301 of EcoStruxure\u2122 Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309 \n\nPlease restart the service after installing the new version. ",
"product_ids": [
"1",
"3",
"5"
],
"restart_required": {
"category": "service"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309"
},
{
"category": "vendor_fix",
"details": "Versions BEL(NL) V2.8.3.0201 and BEL(FR) V2.8.8.0201 of EcoStruxure\u2122 Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability, please reach out to the Schneider Electric Customer Care Center for assistance. ",
"product_ids": [
"7",
"9"
],
"restart_required": {
"category": "service"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: For CVE-2025-13844: - Only open projects from trusted sources - Ensure use of Malware scans before opening any externally created Project",
"product_ids": [
"1",
"3",
"5",
"7",
"9"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"3",
"5",
"7",
"9"
]
}
],
"title": "CVE-2025-13844"
},
{
"acknowledgments": [
{
"organization": "ZDI"
}
],
"cve": "CVE-2025-13845",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "CWE-416: Use After Free vulnerability exists that could cause remote code execution when the end user \r\nimports the malicious project file (SSD file) into Rapsody.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 8.4 | High | [CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)",
"title": "CVSS 4.0 Score"
}
],
"product_status": {
"fixed": [
"2",
"6",
"14",
"10",
"17",
"19",
"21"
],
"known_affected": [
"11",
"12",
"13",
"15",
"16",
"18",
"20"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Versions FR V2.8.1.0401, ESP V2.8.5.0301, PT V2.8.7.0101, INT(EN) V2.8.4.0401, and NL V2.8.2.000 of EcoStruxure\u2122 Power Build Rapsody includes a fix for the CVE-2025-13845 vulnerability and are available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309 \n\nPlease restart the service after installing the new version.",
"product_ids": [
"11",
"12",
"13",
"18",
"20"
],
"restart_required": {
"category": "service"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309"
},
{
"category": "vendor_fix",
"details": "Versions BEL(NL)V2.8.3.0201 and BEL(FR) V2.8.8.0201 of EcoStruxure\u2122 Power Build Rapsody includes a fix for the CVE-2025-13845 vulnerability, please reach out to the Schneider Electric Customer Care Center for assistance.",
"product_ids": [
"15",
"16"
],
"restart_required": {
"category": "service"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: For CVE-2025-13845: - Only open projects from trusted sources - Ensure use of Malware scans before opening any externally created Project",
"product_ids": [
"11",
"12",
"13",
"15",
"16",
"18",
"20"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"11",
"12",
"13",
"15",
"16",
"18",
"20"
]
}
],
"title": "CVE-2025-13845"
}
]
}
CERTFR-2026-AVI-0033
Vulnerability from certfr_avis - Published: 2026-01-14 - Updated: 2026-01-14
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.2.0000 NL | ||
| Schneider Electric | EcoStruxure | EcoStruxure Process Expert versions antérieures à 2025 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.6 INT | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.5 ES | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.7.0100 PT | ||
| Schneider Electric | EcoStruxure | EcoStruxure Process Expert toutes versions pour la vulnérabilité CVE-2025-13905 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.8 BEL(FR) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.3.0100 BEL(EN) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.1.0300 FR | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.1 FR | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.5.0200 ES | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.8.0100 BEL(FR) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.4.0300 INT(EN) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.3 BEL(NL) |
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.2.0000 NL",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert versions ant\u00e9rieures \u00e0 2025",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.6 INT",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.5 ES",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.7.0100 PT",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-13905",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.8 BEL(FR)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.3.0100 BEL(EN)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.1.0300 FR",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.1 FR",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.5.0200 ES",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.8.0100 BEL(FR)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.4.0300 INT(EN)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.3 BEL(NL)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-13845",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13845"
},
{
"name": "CVE-2025-13844",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13844"
},
{
"name": "CVE-2025-13905",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13905"
}
],
"initial_release_date": "2026-01-14T00:00:00",
"last_revision_date": "2026-01-14T00:00:00",
"links": [],
"reference": "CERTFR-2026-AVI-0033",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2026-01-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2026-01-13",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2026-013-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
},
{
"published_at": "2026-01-13",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2026-013-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-02.pdf"
}
]
}
CERTFR-2026-AVI-0033
Vulnerability from certfr_avis - Published: 2026-01-14 - Updated: 2026-01-14
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.2.0000 NL | ||
| Schneider Electric | EcoStruxure | EcoStruxure Process Expert versions antérieures à 2025 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.6 INT | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.5 ES | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.7.0100 PT | ||
| Schneider Electric | EcoStruxure | EcoStruxure Process Expert toutes versions pour la vulnérabilité CVE-2025-13905 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.8 BEL(FR) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.3.0100 BEL(EN) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.1.0300 FR | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.1 FR | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.5.0200 ES | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.8.0100 BEL(FR) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.4.0300 INT(EN) | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Build Rapsody software vers:generic/ versions antérieures ou égales à 2.8.3 BEL(NL) |
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.2.0000 NL",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert versions ant\u00e9rieures \u00e0 2025",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.6 INT",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.5 ES",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.7.0100 PT",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-13905",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.8 BEL(FR)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.3.0100 BEL(EN)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.1.0300 FR",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.1 FR",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.5.0200 ES",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.8.0100 BEL(FR)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.4.0300 INT(EN)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build Rapsody software vers:generic/ versions ant\u00e9rieures ou \u00e9gales \u00e0 2.8.3 BEL(NL)",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-13845",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13845"
},
{
"name": "CVE-2025-13844",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13844"
},
{
"name": "CVE-2025-13905",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13905"
}
],
"initial_release_date": "2026-01-14T00:00:00",
"last_revision_date": "2026-01-14T00:00:00",
"links": [],
"reference": "CERTFR-2026-AVI-0033",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2026-01-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2026-01-13",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2026-013-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
},
{
"published_at": "2026-01-13",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2026-013-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-02.pdf"
}
]
}
GHSA-Q993-4V6G-M56M
Vulnerability from github – Published: 2026-01-15 21:31 – Updated: 2026-01-15 21:31CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
{
"affected": [],
"aliases": [
"CVE-2025-13845"
],
"database_specific": {
"cwe_ids": [
"CWE-416"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2026-01-15T19:16:02Z",
"severity": "HIGH"
},
"details": "CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.",
"id": "GHSA-q993-4v6g-m56m",
"modified": "2026-01-15T21:31:47Z",
"published": "2026-01-15T21:31:47Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-13845"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-26-015-10
Vulnerability from csaf_cisa - Published: 2026-01-13 08:00 - Updated: 2026-03-17 06:00A double-free vulnerability may lead to heap memory corruption when an end user imports a malicious SSD project file shared by an attacker into Rapsody.
A use-after-free vulnerability may allow remote code execution when an end user imports a malicious SSD project file into Rapsody.
{
"document": {
"acknowledgments": [
{
"names": [
"Rocco Calvi"
],
"organization": "in collaboration with Trend Zero Day Initiative (ZDI)",
"summary": "independently reported these vulnerabilities to CISA."
},
{
"names": [
"Michael Heinzl"
],
"summary": "independently reported these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "Schneider Electric strongly recommends the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in sustainability and efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our users.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our users and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its EcoStruxure Power Build Rapsody software. The [EcoStruxure Power Build Rapsody](https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309) is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components. \n\nFailure to apply the mitigations/remediations provided below may risk memory corruption, heap-based buffer overflow, stack-based buffer overflow, which could result in local attackers being able to exploit these issues to potentially execute arbitrary code.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the temporal and environmental metrics. Schneider Electric recommends that users score the CVSS environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a usmer\u0027s environment."
},
{
"category": "other",
"text": "Users should employ appropriate patching methodologies when applying these patches to their systems. Schneider Electric strongly recommends the use of back-ups and evaluating the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center at [https://www.se.com/us/en/work/support/contacts.jsp](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a republication of Schneider Electric SEVD-2026-013-04 from a direct conversion of the vendor\u0027s common security advisory framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Energy, Critical Manufacturing, Commercial Facilities",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "Multiple Vulnerabilities on EcoStruxure Power Build Rapsody - SEVD-2026-013-04 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2026-013-04.json"
},
{
"category": "self",
"summary": "Multiple Vulnerabilities on EcoStruxure Power Build Rapsody - SEVD-2026-013-04 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/ww/en/download/document/7EN52-0390/"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-015-10 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-015-10.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-015-10 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-10"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Schneider Electric EcoStruxure Power Build Rapsody (Update A)",
"tracking": {
"current_release_date": "2026-03-17T06:00:00.000000Z",
"generator": {
"date": "2026-03-16T18:55:02.983970Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-26-015-10",
"initial_release_date": "2026-01-13T08:00:00.000000Z",
"revision_history": [
{
"date": "2026-01-13T08:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Original Release"
},
{
"date": "2026-01-14T22:35:43.622072Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "CISA Republication - Initial Republication of Schneider Electric SEVD-2026-013-04 advisory"
},
{
"date": "2026-03-10T07:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "Removed the link to the fix for Rapsody Belgium version, which was privately communicated to impacted users"
},
{
"date": "2026-03-17T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "4",
"summary": "Update A - Removed link to the fix for Rapsody Belgium version"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.1_FR",
"product": {
"name": "EcoStruxure Power Build Rapsody software FR 2.8.1 and prior",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version",
"name": "2.8.1.0401_FR",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version FR 2.8.1.0401",
"product_id": "CSAFPID-0002"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.6_INT",
"product": {
"name": "EcoStruxure Power Build Rapsody software INT 2.8.6 and prior",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version",
"name": "2.8.6.200_INT",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version INT 2.8.6.200",
"product_id": "CSAFPID-0004"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.5_ES",
"product": {
"name": "EcoStruxure Power Build Rapsody software ES 2.8.5 and prior",
"product_id": "CSAFPID-0005"
}
},
{
"category": "product_version",
"name": "2.8.5.0301_ES",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version ES 2.8.5.0301",
"product_id": "CSAFPID-0006"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.3_BEL(NL)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(NL) 2.8.3 and prior",
"product_id": "CSAFPID-0007"
}
},
{
"category": "product_version",
"name": "2.8.3.0201_BELNL",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version BEL(NL) 2.8.3.0201",
"product_id": "CSAFPID-0008"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.8_BEL(FR)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8 and prior",
"product_id": "CSAFPID-0009"
}
},
{
"category": "product_version",
"name": "2.8.8.0201_BELFR",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version BEL(FR) 2.8.8.0201",
"product_id": "CSAFPID-0010"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.1.0300_FR",
"product": {
"name": "EcoStruxure Power Build Rapsody software FR 2.8.1.0300 and prior",
"product_id": "CSAFPID-0011"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.5.0200_ES",
"product": {
"name": "EcoStruxure Power Build Rapsody software ES 2.8.5.0200 and prior",
"product_id": "CSAFPID-0012"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.7.0100_PT",
"product": {
"name": "EcoStruxure Power Build Rapsody software PT 2.8.7.0100 and prior",
"product_id": "CSAFPID-0013"
}
},
{
"category": "product_version",
"name": "2.8.7.0101_PT",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version PT 2.8.7.0101",
"product_id": "CSAFPID-0014"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.8.0100_BEL(FR)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8.0100 and prior",
"product_id": "CSAFPID-0015"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.3.0100_BEL(EN)",
"product": {
"name": "EcoStruxure Power Build Rapsody software BEL(EN) 2.8.3.0100 and prior",
"product_id": "CSAFPID-0016"
}
},
{
"category": "product_version",
"name": "2.8.3.0201_BELEN",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version BEL(EN) 2.8.3.0201",
"product_id": "CSAFPID-0017"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.4.0300_INT(EN)",
"product": {
"name": "EcoStruxure Power Build Rapsody software INT(EN) 2.8.4.0300 and prior",
"product_id": "CSAFPID-0018"
}
},
{
"category": "product_version",
"name": "2.8.4.0401_INTEN",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version INT(EN) 2.8.4.0401",
"product_id": "CSAFPID-0019"
}
},
{
"category": "product_version_range",
"name": "vers:generic/\u003c=2.8.2.0000_NL",
"product": {
"name": "EcoStruxure Power Build Rapsody software NL 2.8.2.0000 and prior",
"product_id": "CSAFPID-0020"
}
},
{
"category": "product_version",
"name": "2.8.2.000_NL",
"product": {
"name": "EcoStruxure Power Build Rapsody software Version NL 2.8.2.000",
"product_id": "CSAFPID-0021"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Build Rapsody software"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Michael Heinzl"
]
}
],
"cve": "CVE-2025-13844",
"cwe": {
"id": "CWE-415",
"name": "Double Free"
},
"notes": [
{
"category": "description",
"text": "A double-free vulnerability may lead to heap memory corruption when an end user imports a malicious SSD project file shared by an attacker into Rapsody.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 4.6 | Medium | [CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L)",
"title": "CVSS 4.0 Score"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002",
"CSAFPID-0004",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0010"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13844"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/415.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Versions FR V2.8.1.0401, INT V2.8.6.200, and ES V2.8.5.0301 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309 \n\nRestart the service after installing the new version. ",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005"
],
"restart_required": {
"category": "service"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309"
},
{
"category": "vendor_fix",
"details": "Versions BEL(NL) V2.8.3.0201 and BEL(FR) V2.8.8.0201 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability, reach out to the Schneider Electric Customer Care Center for assistance. ",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009"
],
"restart_required": {
"category": "service"
}
},
{
"category": "mitigation",
"details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: For CVE-2025-13844: - Only open projects from trusted sources - Ensure use of malware scans before opening any externally created Project",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009"
]
}
],
"title": "CVE-2025-13844"
},
{
"acknowledgments": [
{
"organization": "ZDI"
}
],
"cve": "CVE-2025-13845",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "A use-after-free vulnerability may allow remote code execution when an end user imports a malicious SSD project file into Rapsody.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 8.4 | High | [CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)",
"title": "CVSS 4.0 Score"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002",
"CSAFPID-0006",
"CSAFPID-0014",
"CSAFPID-0010",
"CSAFPID-0017",
"CSAFPID-0019",
"CSAFPID-0021"
],
"known_affected": [
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0018",
"CSAFPID-0020"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-13845"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/416.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Versions FR V2.8.1.0401, ESP V2.8.5.0301, PT V2.8.7.0101, INT(EN) V2.8.4.0401, and NL V2.8.2.000 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13845 vulnerability and are available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309 \n\nRestart the service after installing the new version.",
"product_ids": [
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0018",
"CSAFPID-0020"
],
"restart_required": {
"category": "service"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=2309"
},
{
"category": "vendor_fix",
"details": "Versions BEL(NL)V2.8.3.0201 and BEL(FR) V2.8.8.0201 of EcoStruxure Power Build Rapsody include a fix for the CVE-2025-13845 vulnerability, reach out to the Schneider Electric Customer Care Center for assistance.",
"product_ids": [
"CSAFPID-0015",
"CSAFPID-0016"
],
"restart_required": {
"category": "service"
}
},
{
"category": "mitigation",
"details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: For CVE-2025-13845: - Only open projects from trusted sources - Ensure use of malware scans before opening any externally created Project",
"product_ids": [
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0018",
"CSAFPID-0020"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0018",
"CSAFPID-0020"
]
}
],
"title": "CVE-2025-13845"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.